journal article·2003-08-01

Do in vivo terahertz imaging systems comply with safety guidelines?

Elizabeth Berry, Gillian C. Walker, Anthony J. Fitzgerald, N. N. Zinov’ev, Martyn Chamberlain, Stephen W. Smye, Robert E. Miles, Michael A. Smith

Journal of Laser Applications· Volume 15· Issue 3
Publisher page

Abstract

Techniques for the coherent generation and detection of electromagnetic radiation in the far infrared, or terahertz, region of the electromagnetic spectrum have recently developed rapidly and may soon be applied for in vivo medical imaging. Both continuous wave and pulsed imaging systems are under development, with terahertz pulsed imaging being the more common method. Typically a pump and probe technique is used, with picosecond pulses of terahertz radiation generated from femtosecond infrared laser pulses, using an antenna or nonlinear crystal. After interaction with the subject either by transmission or reflection, coherent detection is achieved when the terahertz beam is combined with the probe laser beam. Raster scanning of the subject leads to an image data set comprising a time series representing the pulse at each pixel. A set of parametric images may be calculated, mapping the values of various parameters calculated from the shape of the pulses. A safety analysis has been performed, based on current guidelines for skin exposure to radiation of wavelengths 2.6 μm–20 mm (15 GHz–115 THz), to determine the maximum permissible exposure (MPE) for such a terahertz imaging system. The international guidelines for this range of wavelengths are drawn from two U.S. standards documents. The method for this analysis was taken from the American National Standard for the Safe Use of Lasers (ANSI Z136.1), and to ensure a conservative analysis, parameters were drawn from both this standard and from the IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields (C95.1). The calculated maximum permissible average beam power was 3 mW, indicating that typical terahertz imaging systems are safe according to the current guidelines. Further developments may however result in systems that will exceed the calculated limit. Furthermore, the published MPEs for pulsed exposures are based on measurements at shorter wavelengths and with pulses of longer duration than those used in terahertz pulsed imaging systems, so the results should be treated with caution.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Terahertz technology and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Academic Unit of Medical Physics and Centre of Medical Imaging Research, University of Leeds, Wellcome Wing, Leeds General Infirmary, Leeds LS1 3EX, United Kingdom

Institute of Microwaves and Photonics, University of Leeds, Leeds LS2 9JT, United Kingdom

Department of Medical Physics and Engineering, Leeds Teaching Hospitals NHS Trust, St. James’s University Hospital, Leeds LS9 7TF, United Kingdom

References (29)

Show source-provided references
1. Subpicosecond photoconducting dipole antennas10.1109/3.121 ↗
2. High-brightness terahertz beams characterized with an ultrafast detector10.1063/1.101901 ↗
3. Imaging with terahertz waves10.1364/OL.20.001716 ↗
4. T-ray imaging10.1109/2944.571768 ↗
5. Chemistry is right for T-ray imaging10.1109/101.485909 ↗
6. Time-domain spectroscopy targets the far-infrared
7. Recent advances in terahertz imaging10.1007/s003400050750 ↗
8. Terahertz imaging and spectroscopy of human skin, in-vivo10.1117/12.428010 ↗
9. Biomedical applications of terahertz pulse imaging10.1117/12.386349 ↗
10. Diagnosis of dental cavity and osteoporosis using terahertz transmission images10.1007/978-3-642-56546-5_78 ↗
11. Coherent time-domain far-infrared spectroscopy with femtosecond pulses
12. Electrooptic generation and detection of femtosecond electrical transients10.1109/3.114 ↗
13. Optoelectronic study of piezoelectric field in strained-layer superlattices10.1016/0749-6036(92)90306-P ↗
14. Two-dimensional electro-optic imaging of THz beams10.1063/1.116920 ↗
15. Single-shot measurement of terahertz electromagnetic pulses by use of electro-optic sampling10.1364/OL.25.000426 ↗
16. Analysis of system trade-offs for terahertz imaging10.1016/S0026-2692(00)00023-9 ↗
17. Guidelines on limits of exposure to laser radiation of wavelengths between 180 nm and 1,000 μm
18. Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz)
19. Safety aspects of laser scanning ophthalmoscopes10.1097/00004032-198607000-00006 ↗
20. In vivo optical coherence tomography imaging of human skin: norm and pathology10.1034/j.1600-0846.2000.006001006.x ↗
21. Laser hazard evaluation method for middle infrared laser systems10.2351/1.4745424 ↗
22. A procedure for multiple-pulse maximum permissible exposure determination under the Z136.1-2000 American National Standard for Safe Use of Lasers10.2351/1.1386796 ↗
23. Radiation safety—the maximum permissible exposure levels—our knowledge of the hazards10.1016/0030-3992(89)90082-0 ↗
24. Far-infrared dielectric properties of polar liquids probed by femtosecond terahertz pulse spectroscopy10.1021/jp960141g ↗
25. The interaction between terahertz radiation and biological tissue10.1088/0031-9155/46/9/201 ↗
26. THz reflection spectroscopy of liquid water10.1016/0009-2614(95)00543-D ↗
27. Millimeter wave absorption in the nonhuman primate eye at 35 GHz and 94 GHz10.1097/00004032-200207000-00009 ↗
28. Proposed maximum permissible exposure limits for ultrashort laser pulses10.1097/00004032-199904000-00002 ↗
29. Generation of terahertz pulses by photoionization of electrically biased air10.1063/1.127007 ↗