journal article·2018-03

On the improvement of the dynamic performance of dielectric elastomer actuators for active compression

Hamza Edher, Armaghan Salehian

Publisher page

Abstract

Dielectric elastomer actuators have been considered for an increasing number of applications due to their desirable characteristics of low weight, high strain outputs and favourable material costs. The present work describes the use of a dielectric elastomer actuator in conjunction with a belt mechanism to apply cyclic active compression. The belt mechanism helps convert the stress relaxation upon the voltage application to the dielectric elastomer actuator to a compressive force. Testing is conducted using multi-layered silicone–based dielectric elastomer actuators. A novel method of dynamically charging dielectric elastomer actuators through manipulating the input signal shape, termed the hold method, is introduced. Using this method, cyclic actuation strain output can be increased by 24% with insignificant change in actuation output curve shape. Furthermore, the effect of pre-stretch ratios on the output force amplitudes is characterized. The optimized hold time parameters obtained through cyclic dielectric elastomer force and strain are utilized for active compression physiological testing and a pressure gradient of 10 mmHg is achieved.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dielectric materials and actuators · Advanced Sensor and Energy Harvesting Materials · Vibration Control and Rheological Fluids

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON, Canada

References (41)

Show source-provided references
1. 10.1063/1.479342010.1063/1.4793420 ↗
2. 10.1061/40476(299)2410.1061/40476(299)24 ↗
3. 10.1007/s00421-016-3331-010.1007/s00421-016-3331-0 ↗
4. 10.1067/mhl.2001.11600910.1067/mhl.2001.116009 ↗
5. Carpi F · 2011
6. 10.1088/0964-1726/24/10/10502510.1088/0964-1726/24/10/105025 ↗
7. 10.1016/S0924-4247(03)00257-710.1016/S0924-4247(03)00257-7 ↗
8. DuPont · 2017
9. Edher H, Maupas L, Nijjer S, et al. (2018) Utilizing tension reduction in a dielectric elastomer actuator to produce compression for physiological application.10.1177/1045389X17754254 ↗
10. 10.1016/j.jmps.2008.03.00710.1016/j.jmps.2008.03.007 ↗
11. 10.1117/12.48438810.1117/12.484388 ↗
12. 10.1007/s10286-004-1004-210.1007/s10286-004-1004-2 ↗
13. 10.3357/AMHP.4349.201610.3357/AMHP.4349.2016 ↗
14. 10.1016/j.matdes.2013.11.08410.1016/j.matdes.2013.11.084 ↗
15. 10.1155/2012/69485110.1155/2012/694851 ↗
16. 10.1016/j.jtv.2012.09.00210.1016/j.jtv.2012.09.002 ↗
17. Lao S · 2016
18. 10.1111/j.1445-2197.2004.02994.x10.1111/j.1445-2197.2004.02994.x ↗
19. 10.2165/11591420-000000000-0000010.2165/11591420-000000000-00000 ↗
20. 10.1002/marc.20150057610.1002/marc.201500576 ↗
21. 10.1002/adfm.20140394210.1002/adfm.201403942 ↗
22. 10.1186/1475-925X-13-13510.1186/1475-925X-13-135 ↗
23. 10.1063/1.321195710.1063/1.3211957 ↗
24. 10.1097/SLA.0b013e3181b5d61c10.1097/SLA.0b013e3181b5d61c ↗
25. 10.1016/j.matlet.2006.03.05310.1016/j.matlet.2006.03.053 ↗
26. Pedegana LR · Clinical Orthopaedics and Related Research · 1977 · 128 · 190
27. 10.1016/S0379-6779(02)00535-010.1016/S0379-6779(02)00535-0 ↗
28. 10.1126/science.287.5454.83610.1126/science.287.5454.836 ↗
29. 10.1007/s11012-015-0270-510.1007/s11012-015-0270-5 ↗
30. Plante J · 2006
31. 10.1088/0964-1726/16/2/S0510.1088/0964-1726/16/2/S05 ↗
32. 10.1088/0964-1726/23/6/06500710.1088/0964-1726/23/6/065007 ↗
33. 10.1302/0301-620X.86B6.1395810.1302/0301-620X.86B6.13958 ↗
34. 10.1152/jappl.1992.72.6.206310.1152/jappl.1992.72.6.2063 ↗
35. 10.1007/978-1-4613-1463-9_910.1007/978-1-4613-1463-9_9 ↗
36. Vanek V · American Surgeon · 1998 · 11 · 1050
37. 10.1080/17461391.2012.73006210.1080/17461391.2012.730062 ↗
38. Vogan J · 2004
39. 10.1016/j.sna.2009.09.00310.1016/j.sna.2009.09.003 ↗
40. 10.1016/j.mtcomm.2015.08.00210.1016/j.mtcomm.2015.08.002 ↗
41. Zuj KA · 2015