Orthosis with a controllable plantar height for fall prevention using a compact magnetorheological fluid brake
Source abstract
Abstract
In this study, a compact magnetorheological (MR) fluid brake embedded in an orthosis was designed and fabricated to maintain plantar height for use in lateral fall prevention, and its performance and the fall prevention effect of the orthosis were evaluated. The results of the brake design and fabrication indicated that the MR fluid brake has the advantage of being compact, lightweight, and power-saving at 88.4 mm long, 128 g, using two AA batteries. Performance tests of the brake indicated that it was able to generate sufficient force (125 N) to maintain plantar height. Furthermore, through the assessments of lateral fall, the center of gravity and center of pressure inclination angle of a subject wearing the orthosis without the MR brake was determined to be 4.0°, as opposed to 4.4° with the MR fluid brake in the ON state. Therefore, the moment of force acting on the subject to prevent fall was larger, making them more stable when the MR fluid brake was in the ON state.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Balance, Gait, and Falls Prevention · Diabetic Foot Ulcer Assessment and Management · Prosthetics and Rehabilitation Robotics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Graduate School of Environment and Information Sciences, Yokohama National University, Yokohama, Japan
Department of Rehabilitation Medicine, Keio University School of Medicine, Tokyo, Japan
References (33)
Show source-provided references
1. Andrew PD · 2018
2. 10.2522/ptj.2005038710.2522/ptj.20050387 ↗
3. 10.1186/s13047-018-0291-010.1186/s13047-018-0291-0 ↗
4. 10.3109/0001648920910077810.3109/00016489209100778 ↗
5. 10.1093/geronj/44.4.M10710.1093/geronj/44.4.M107 ↗
6. Iritani M · 2017
7. Ishiguro T · 1978
8. 10.1093/gerona/53A.2.M12610.1093/gerona/53A.2.M126 ↗
9. 10.1589/rika.29.60510.1589/rika.29.605 ↗
10. 10.1177/01945998931090041710.1177/019459989310900417 ↗
11. 10.1109/7333.91827910.1109/7333.918279 ↗
12. 10.1016/j.apmr.2005.11.03310.1016/j.apmr.2005.11.033 ↗
13. 10.1016/0021-9290(93)90027-C10.1016/0021-9290(93)90027-C ↗
14. 10.1093/ageing/32.2.13710.1093/ageing/32.2.137 ↗
15. Ministry of Land, Infrastructure, Transport and Tourism · 2003
16. 10.1299/jsmedmc.2019.45410.1299/jsmedmc.2019.454 ↗
17. 10.1299/jsmeintmovic.2020.15.1006710.1299/jsmeintmovic.2020.15.10067 ↗
18. 10.1093/geronj/24.2.16910.1093/geronj/24.2.169 ↗
19. Naikwadi A · International Research Journal of Engineering and Technology · 2017 · 4 · 408
20. Nakamura R · 2005
21. 10.1007/s12206-019-0828-610.1007/s12206-019-0828-6 ↗
22. Omuro K · Journal of Physical Therapy Science · 2011 · 26 · 55
23. 10.3389/fmats.2019.0001910.3389/fmats.2019.00019 ↗
24. 10.1088/0964-1726/23/11/11700110.1088/0964-1726/23/11/117001 ↗
25. 10.1088/0964-1726/23/12/12502210.1088/0964-1726/23/12/125022 ↗
26. 10.1109/T-AIEE.1948.505982110.1109/T-AIEE.1948.5059821 ↗
27. 10.1299/kikaic.70.230810.1299/kikaic.70.2308 ↗
28. 10.1299/kikaic.77.219310.1299/kikaic.77.2193 ↗
29. 10.1088/1742-6596/744/1/01201210.1088/1742-6596/744/1/012012 ↗
30. Statistic Bureau of Japan (2016) Statistical handbook of Japan 2016. Available at: https://www.stat.go.jp/data/nihon/pdf/16nihon.pdf (accessed 15 February 2021).
31. Takai I · Japanese Journal of Physiological Anthropology · 2001 · 6 · 11
32. 10.15563/jalliedhealthsci.7.710.15563/jalliedhealthsci.7.7 ↗
33. WHO Scientific Group · 2003