Smart Rehabilitation Devices: Part II – Adaptive Motion Control
Source abstract
Abstract
This article presents a study of adaptive motion control of smart versatile rehabilitation devices using MR fluids. The device provides both isometric and isokinetic strength training and is reconfigurable for several human joints. Adaptive controls are developed to regulate resistance force based on the prescription of the therapist. Special consideration has been given to the human–machine interaction in the adaptive control that can modify the behavior of the device to account for strength gains or muscle fatigue of the human subject.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Muscle activation and electromyography studies · Stroke Rehabilitation and Recovery · Prosthetics and Rehabilitation Robotics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Engineering, University of Delaware, Newark, DE 19716, USA
Department of Mechanical Engineering, University of Delaware, Newark, DE 19716, USA;
Department of Physical Therapy, University of Delaware, Newark, DE 19716, USA
References (29)
Show source-provided references
1. 10.1053/apmr.2003.5000310.1053/apmr.2003.50003 ↗
2. 10.1016/S0140-6736(97)07226-710.1016/S0140-6736(97)07226-7 ↗
3. 10.1053/apmr.2000.557910.1053/apmr.2000.5579 ↗
4. 10.1016/S0021-9290(02)00190-210.1016/S0021-9290(02)00190-2 ↗
5. 10.1016/S0021-9290(99)00039-110.1016/S0021-9290(99)00039-1 ↗
6. 10.1053/apmr.2002.3428610.1053/apmr.2002.34286 ↗
7. Dong, S. · Journal of Intelligent Material Systems and Structures · 2005
8. 10.1152/jappl.1990.69.6.221510.1152/jappl.1990.69.6.2215 ↗
9. Elmer, K.F. · Proceedings of the Institution of Mechanical Engineers – Part C · 2001 · 215 · 1357
10. Felson, D. · Seminars in Arthritis and Rheumatism · 1990 · 20 · 4210.1016/0049-0172(90)90046-I ↗
11. 10.1016/0003-9993(93)90011-X10.1016/0003-9993(93)90011-X ↗
12. 10.1113/jphysiol.1966.sp00790910.1113/jphysiol.1966.sp007909 ↗
13. 10.1098/rspb.1938.005010.1098/rspb.1938.0050 ↗
14. 10.1053/sarh.2003.5002110.1053/sarh.2003.50021 ↗
15. 10.1016/S1058-2746(02)86886-010.1016/S1058-2746(02)86886-0 ↗
16. Kearney, R.E. · Critical Reviews in Biomedical Engineering · 1990 · 18 · 55
17. 10.1016/S0021-9290(00)00070-110.1016/S0021-9290(00)00070-1 ↗
18. 10.1016/S0021-9290(03)00010-110.1016/S0021-9290(03)00010-1 ↗
19. 10.1080/00365500075004572110.1080/003655000750045721 ↗
20. 10.1016/S1063-4584(02)00372-210.1016/S1063-4584(02)00372-2 ↗
21. 10.1016/S0966-6362(99)00018-110.1016/S0966-6362(99)00018-1 ↗
22. Slotine, J.–J.E. · 1991
23. 10.1016/S0736-0266(03)00052-410.1016/S0736-0266(03)00052-4 ↗
24. 10.1016/S0003-9993(99)90018-710.1016/S0003-9993(99)90018-7 ↗
25. 10.1115/1.153111210.1115/1.1531112 ↗
26. 10.1053/apmr.2002.3398810.1053/apmr.2002.33988 ↗
27. 10.1115/1.280113110.1115/1.2801131 ↗
28. 10.1016/S1521-6942(03)00043-310.1016/S1521-6942(03)00043-3 ↗
29. 10.1109/TNSRE.2002.102158410.1109/TNSRE.2002.1021584 ↗