Utilizing tension reduction in a dielectric elastomer actuator to produce compression for physiological application
Source abstract
Abstract
A common prophylaxis against peripheral vascular diseases utilizes pneumatic active compression systems. Although effective, traditional active compression systems require the use of an air compressor and pump and are, therefore, ill-suited for ambulatory use. The current work introduces a novel approach to developing an ambulatory smart material–based active compression system. The actuation system is composed of a belt-like mechanism connected in conjunction with a multi-layered dielectric elastomer actuator. The belt mechanism allows compression to be applied directly with voltage application. By doing so, the proposed design limits the period during which the actuator should be charged and improves system power efficiency and lifetime. An analytical model which defines the pre-compression exerted by the actuation system before voltage application is presented and validated experimentally. Experimental results for the belt mechanism characterization, dielectric elastomer actuator characterization and actuation system testing are presented. Through experimental testing, it is shown that the initial pre-compression can be fine-tuned by varying the parameters of the system as defined in the analytical model, and that the pre-compression has little effect on the consequent actuation output amplitudes.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dielectric materials and actuators · Advanced Sensor and Energy Harvesting Materials · Vibration Control and Rheological Fluids
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Mechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, ON, Canada
References (37)
Show source-provided references
1. 10.1061/40476(299)2410.1061/40476(299)24 ↗
2. 10.1007/s00421-016-3331-010.1007/s00421-016-3331-0 ↗
3. 10.1067/mhl.2001.11600910.1067/mhl.2001.116009 ↗
4. Carpi F · 2011
5. 10.1088/0964-1726/24/10/10502510.1088/0964-1726/24/10/105025 ↗
6. 10.1016/S0924-4247(03)00257-710.1016/S0924-4247(03)00257-7 ↗
7. Goulbourne NC · Smart Structures and Materials · 2004 · 5385 · 122
8. Goulbourne NC · Smart Structures and Materials · 2003 · 5051 · 319
9. 10.1109/PEAC.2014.703800710.1109/PEAC.2014.7038007 ↗
10. 10.1016/j.matdes.2013.11.08410.1016/j.matdes.2013.11.084 ↗
11. 10.1001/archinte.158.21.231510.1001/archinte.158.21.2315 ↗
12. 10.1155/2012/69485110.1155/2012/694851 ↗
13. 10.1111/j.0954-6820.1987.tb10957.x10.1111/j.0954-6820.1987.tb10957.x ↗
14. 10.1016/j.sna.2005.05.00110.1016/j.sna.2005.05.001 ↗
15. 10.1117/12.47507210.1117/12.475072 ↗
16. Lao S · 2016
17. 10.2165/11591420-000000000-0000010.2165/11591420-000000000-00000 ↗
18. Moein H · Biomedical Engineering on Line · 2014 · 13 · 135
19. 10.1063/1.321195710.1063/1.3211957 ↗
20. 10.1097/SLA.0b013e3181b5d61c10.1097/SLA.0b013e3181b5d61c ↗
21. 10.1098/rspa.1972.002610.1098/rspa.1972.0026 ↗
22. 10.1016/j.jvs.2005.06.03010.1016/j.jvs.2005.06.030 ↗
23. Pedegana L · Clinical Orthopaedics and Related Research · 1977 · 128 · 190
24. 10.1016/S0379-6779(02)00535-010.1016/S0379-6779(02)00535-0 ↗
25. 10.1126/science.287.5454.83610.1126/science.287.5454.836 ↗
26. 10.1016/S0928-4931(00)00128-410.1016/S0928-4931(00)00128-4 ↗
27. 10.1117/12.47515710.1117/12.475157 ↗
28. 10.1007/s11012-015-0270-510.1007/s11012-015-0270-5 ↗
29. 10.1016/j.ijsolstr.2006.03.02610.1016/j.ijsolstr.2006.03.026 ↗
30. 10.1088/0964-1726/16/2/S0510.1088/0964-1726/16/2/S05 ↗
31. 10.1088/0964-1726/23/6/06500710.1088/0964-1726/23/6/065007 ↗
32. 10.1253/circj.70.115910.1253/circj.70.1159 ↗
33. 10.1007/978-1-4613-1463-9_910.1007/978-1-4613-1463-9_9 ↗
34. Vanek V · American Surgeon · 1998 · 64 · 1050
35. Vogan J · 2004
36. 10.1109/HAPTIC.2006.162713710.1109/HAPTIC.2006.1627137 ↗
37. 10.1152/japplphysiol.00784.201710.1152/japplphysiol.00784.2017 ↗