Abstract

A new magnetorheological (MR) damper has been designed, manufactured, modelled and tested under cyclic loads. A faulty behaviour of the damper was accidentally detected during the experiments. It was deduced that the presence of air bubbles within the MR fluid is the main reason for that failure mode of the damper. The AMT-Smartec + MR fluid used in the current study, a new MR fluid whose characteristics are not available in the literature, exhibits good magnetic properties. However, the fluid has a very high viscosity in the absence of magnetic field. It is assumed that this high viscosity enables the retention of air bubbles in the damper and causes the faulty behaviour. To prove this assumption, a coupled numerical approach has been developed. The approach incorporates a Finite Element Analysis (FEA) of the magnetic circuit and a Computational Fluid Dynamics (CFD) analysis of the fluid flow. A similar approach was presented in a previous publication in which an ideal behaviour of an MR damper (no effect of air bubbles) was investigated. The model has been modified in the current study to include the effect of air bubbles. The results were found to support the assumptions for the reasons of the failure symptoms of the current MR damper. The results are shown in a comparative way between the former and current studies to show the differences in flow parameters, namely: pressure, velocity and viscosity, in the faultless and faulty modes. The results indicate that the presence of air bubbles in MR dampers reduces the damper force considerably. Therefore, the effect of the high yield stress of MR fluids due to the magnetic field is reduced.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Vibration Control and Rheological Fluids · Hydraulic and Pneumatic Systems · Fluid Dynamics and Vibration Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical, Aerospace and Civil Engineering, School of Engineering, Faculty of Science and Engineering, The University of Manchester, Manchester, UK

Mechanical Engineering Branch, Military Technical College, Cairo, Egypt

References (80)

Show source-provided references
1. 10.3390/fluids401000510.3390/fluids4010005 ↗
2. 10.1088/2053-1591/aae14110.1088/2053-1591/aae141 ↗
3. 10.1155/2015/90518610.1155/2015/905186 ↗
4. Arus MR Tech (2018) AMT-Smartec + . Available at: https://secureservercdn.net/160.153.137.16/1jc.c8f.myftpupload.com/wp-content/uploads/2018/09/smartec_tds_pdf.pdf (accessed 17 March 2018).
5. 10.1088/0964-1726/24/8/08501410.1088/0964-1726/24/8/085014 ↗
6. 10.1109/TMAG.2013.224140210.1109/TMAG.2013.2241402 ↗
7. 10.1177/1045389X1247435510.1177/1045389X12474355 ↗
8. 10.1088/1361-665X/ab034710.1088/1361-665X/ab0347 ↗
9. 10.1016/j.simpat.2011.01.00110.1016/j.simpat.2011.01.001 ↗
10. 10.1177/1045389X1143349710.1177/1045389X11433497 ↗
11. 10.1016/j.compstruc.2007.01.04310.1016/j.compstruc.2007.01.043 ↗
12. 10.1260/1750-9548.7.1.6110.1260/1750-9548.7.1.61 ↗
13. 10.1109/TMECH.2013.226570110.1109/TMECH.2013.2265701 ↗
14. 10.1016/j.ijmecsci.2010.04.00710.1016/j.ijmecsci.2010.04.007 ↗
15. 10.1088/0964-1726/24/1/01700110.1088/0964-1726/24/1/017001 ↗
16. 10.1109/TMAG.2018.279709010.1109/TMAG.2018.2797090 ↗
17. Chooi WW · 2005
18. 10.1016/j.compstruc.2007.02.00210.1016/j.compstruc.2007.02.002 ↗
19. 10.1115/1.314288510.1115/1.3142885 ↗
20. 10.1115/1.314288410.1115/1.3142884 ↗
21. COMSOL · 2018
22. Czop P · Computer Assisted Methods in Engineering and Science · 2017 · 23 · 171
23. 10.1007/s40430-019-1833-510.1007/s40430-019-1833-5 ↗
24. 10.1088/0964-1726/22/11/11500310.1088/0964-1726/22/11/115003 ↗
25. 10.1088/0964-1726/13/6/00810.1088/0964-1726/13/6/008 ↗
26. 10.3849/aimt.0128710.3849/aimt.01287 ↗
27. 10.1016/j.ijmecsci.2019.10526510.1016/j.ijmecsci.2019.105265 ↗
28. 10.1177/1045389X2093563210.1177/1045389X20935632 ↗
29. 10.1109/CarpathianCC.2017.797041610.1109/CarpathianCC.2017.7970416 ↗
30. 10.1177/1045389X1350057610.1177/1045389X13500576 ↗
31. 10.1155/2019/938304710.1155/2019/9383047 ↗
32. 10.3389/fmats.2019.0029310.3389/fmats.2019.00293 ↗
33. 10.1007/s40430-018-1066-z10.1007/s40430-018-1066-z ↗
34. Gurubasavaraju M · Proceedings of the Institution of Mechanical Engineers, Part D: Journal of Automobile Engineering · 2018 · 233 · 1214
35. 10.2514/1.C03529810.2514/1.C035298 ↗
36. 10.1016/j.engfailanal.2009.09.01010.1016/j.engfailanal.2009.09.010 ↗
37. 10.1088/0964-1726/23/7/07502710.1088/0964-1726/23/7/075027 ↗
38. 10.1088/1742-6596/659/1/01203710.1088/1742-6596/659/1/012037 ↗
39. 10.1088/0964-1726/17/4/04502110.1088/0964-1726/17/4/045021 ↗
40. 10.1007/978-1-4471-0099-710.1007/978-1-4471-0099-7 ↗
41. 10.1088/0964-1726/6/3/01210.1088/0964-1726/6/3/012 ↗
42. 10.1088/0964-1726/25/7/07500410.1088/0964-1726/25/7/075004 ↗
43. 10.1155/2016/618284710.1155/2016/6182847 ↗
44. 10.1155/2016/742861610.1155/2016/7428616 ↗
45. 10.1186/s40712-019-0109-210.1186/s40712-019-0109-2 ↗
46. Li S · Science Progress · 2019 · 103 · 00368504198790010.1177/0036850419879000 ↗
47. Liquids Research Ltd (2018) Magnetorheological fluids. Available at: https://liquidsresearch.com/en-GB/document_download-58.aspx (accessed 17 March 2018).
48. Lord Corporation (2017) MRF-132DG magneto-rheological fluid. Available at: https://www.lord.com/sites/default/files/Documents/TechnicalDataSheet/DS7015_MRF-132DGMRFluid.pdf (accessed 11 December 2017).
49. Macháček O · 2019
50. 10.1088/1361-665X/ab421a10.1088/1361-665X/ab421a ↗
51. 10.4028/www.scientific.net/KEM.739.25210.4028/www.scientific.net/KEM.739.252 ↗
52. Morato MM, Pham T-P, Villa MM, et al. (2018) Modelling of electro-rheological dampers for automotive suspensions: Healthy and faulty cases. Hyper Articles en Ligne (HAL). Available at: http://hal.univ-grenoble-alpes.fr/hal-01826641/document (accessed 03 June 2020).
53. 10.1016/j.jmmm.2009.01.00210.1016/j.jmmm.2009.01.002 ↗
54. 10.1016/j.ijmecsci.2012.08.00610.1016/j.ijmecsci.2012.08.006 ↗
55. 10.1007/978-981-13-0365-4_3710.1007/978-981-13-0365-4_37 ↗
56. 10.1017/CBO978113901297310.1017/CBO9781139012973 ↗
57. 10.3390/act702001610.3390/act7020016 ↗
58. 10.1177/1045389X1244798410.1177/1045389X12447984 ↗
59. 10.1088/0964-1726/20/10/10500710.1088/0964-1726/20/10/105007 ↗
60. 10.1088/1361-665X/ab0b8e10.1088/1361-665X/ab0b8e ↗
61. 10.1016/j.jnnfm.2016.02.01110.1016/j.jnnfm.2016.02.011 ↗
62. 10.1063/1.501175510.1063/1.5011755 ↗
63. Tao R (2019) Reducing blood viscosity and suppressing turbulence with magnetic field to prevent heart attack and stroke (Conference Presentation). In: Razeghi M, Lewis JS, Tournié E, et al. (eds) Proceedings of SPIE 10926, Quantum Sensing and Nano Electronics and Photonics XVI. San Francisco, CA: SPIE. https://doi.org/10.1117/1112.2513233.10.1117/12.2513233 ↗
64. 10.1007/s12206-018-0308-410.1007/s12206-018-0308-4 ↗
65. 10.3390/ma1111219510.3390/ma11112195 ↗
66. Vacuumschmelze GmbH (2018a) Vacoflux 27 preliminary datasheet. Available at: https://indico.cern.ch/event/682107/attachments/1560598/2465487/VACOFLUX_27_preliminary_datasheet.pdf (accessed 23 April 2018).
67. Vacuumschmelze GmbH (2018b) Vacoflux - magnetic properties. Available at: https://vacuumschmelze.de/Produkte/Weichmagnetische-Werkstoffe-und-Stanzteile/49-Kobalt-Eisen-VACOFLUX-und-VACODUR (accessed 23 April 2018).
68. 10.1007/s11223-018-9979-410.1007/s11223-018-9979-4 ↗
69. 10.1088/0964-1726/20/2/02300110.1088/0964-1726/20/2/023001 ↗
70. 10.1088/0964-1726/18/9/09502510.1088/0964-1726/18/9/095025 ↗
71. 10.1088/0964-1726/15/6/02710.1088/0964-1726/15/6/027 ↗
72. 10.1088/0964-1726/13/4/01210.1088/0964-1726/13/4/012 ↗
73. 10.1177/1045389X980090081010.1177/1045389X9800900810 ↗
74. 10.1088/1757-899X/576/1/01201410.1088/1757-899X/576/1/012014 ↗
75. 10.1177/1045389X1244562910.1177/1045389X12445629 ↗
76. 10.1177/1045389X1347615110.1177/1045389X13476151 ↗
77. Zhang Y · 2015
78. 10.1155/2014/40250110.1155/2014/402501 ↗
79. 10.1088/0964-1726/24/10/10502410.1088/0964-1726/24/10/105024 ↗
80. 10.1177/095440621664310910.1177/0954406216643109 ↗