Decomposition of the Pressure Response in an ER Valve Control System
Source abstract
Abstract
Experimental data from tests on an ER valve pertinent to the development of a con troller for high speed machine duty has been analysed to show that three common, underlying modes of response are present. This is demonstrated for a range of industrial scale flow velocities and electrode dimensions, in the time and frequency domains. The dependence of steady-state pressure on the electric field is also discussed.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Hydraulic and Pneumatic Systems · Advanced Sensor and Control Systems · Vibration Control and Rheological Fluids
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical and Process Engineering The University of Sheffield P.O. Box 600 Sheffield S1 4DU, United Kingdom
References (9)
Show source-provided references
1. Aseltine, J.A. · 1958
2. 10.1063/1.46207010.1063/1.462070 ↗
3. Bullough, W.A. · I. Mech. E. · 1990
4. 10.1021/la00091a00310.1021/la00091a003 ↗
5. Press, W.H., B.P. Flannery, S.A. Teukolsky and W.T. Vetterling , 1986. Numerical Recipes. Cambridge Umversity Press, p. 289.
6. Ogata, K. · 1978
7. Tao, R. · 1991
8. 10.1016/0377-0257(90)90007-X10.1016/0377-0257(90)90007-X ↗
9. Whittle, M.