Parametric study of a triboelectric transducer in total knee replacement application
Source abstract
Abstract
Triboelectric energy harvesting is a relatively new technology showing promise for biomedical applications. This study investigates a triboelectric energy transducer for potential applications in total knee replacement both as an energy harvester and a sensor. The sensor can be used to monitor loads at the knee joint. The proposed transducer generates an electrical signal that is directly related to the periodic mechanical load from walking. The proportionality between the generated electrical signal and the load transferred to the knee enables triboelectric transducers to be used as self-powered active load sensors. We analyzed the performance of a triboelectric transducer when subjected to simulated gait loading on a joint motion simulator. Two different designs were evaluated: one made of Titanium on Aluminum (Ti-PDMS-Al) and the other made of Titanium on Titanium (Ti-PDMS-Ti). The Ti-PDMS-Ti design generates more power than Ti-PDMS-Al and was used to optimize the structural parameters. Our analysis found these optimal parameters for the Ti-PDMS-Ti design: external resistance of 304 MΩ, a gap of 550 µm, and a thickness of the triboelectric layer of 50 µm. Those parameters were optimized by varying resistance, gap, and the thickness while measuring the power outputs. Using the optimized parameters, the transducer was tested under different axial loads to check the viability of the harvester to act as a self-powered load sensor to estimate the knee loads. The forces transmitted across the knee joint during activities of daily living can be directly measured and used for self-powering, which can lead to improving the total knee implant functions.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Muscle activation and electromyography studies · Conducting polymers and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
University of Texas at Tyler, Tyler, TX, USA
University of Western Ontario, London, ON, Canada
Binghamton University, Binghamton, NY, USA
Funding
National Health Fund
References (59)
Show source-provided references
1. 10.1109/PHT.2013.646127110.1109/PHT.2013.6461271 ↗
2. 10.1038/ncomms592910.1038/ncomms5929 ↗
3. 10.1126/science.120151210.1126/science.1201512 ↗
4. 10.1371/journal.pone.008603510.1371/journal.pone.0086035 ↗
5. 10.1097/00152258-200703000-0000910.1097/00152258-200703000-00009 ↗
6. 10.1016/j.elstat.2016.01.00210.1016/j.elstat.2016.01.002 ↗
7. 10.1109/JMEMS.2014.231771810.1109/JMEMS.2014.2317718 ↗
8. 10.1016/j.arth.2005.07.01110.1016/j.arth.2005.07.011 ↗
9. 10.1016/j.jbiomech.2007.03.00410.1016/j.jbiomech.2007.03.004 ↗
10. 10.1016/j.jbiomech.2004.02.01110.1016/j.jbiomech.2004.02.011 ↗
11. 10.1016/j.nanoen.2012.01.00410.1016/j.nanoen.2012.01.004 ↗
12. Farhangdoust S, Mehrabi A, Younesian D (2019) Bistable wind-induced vibration energy harvester for selfpowered wireless sensors in smart bridge monitoring systems. In: Nondestructive characterization and monitoring of advanced materials, aerospace, civil infrastructure, and transportation XIII, volume 10971, Denver, CO, USA, p. 109710C. International Society for Optics and Photonics. Available at: https://www.spiedigitallibrary.org/conference-proceedings-of-spie/10971/109710C/Bistable-wind-induced-vibration-energy-harvester-for-self-powered-wireless/10.1117/12.2517424.short?SSO=110.1117/12.2517424 ↗
13. Gomes A, Rodrigues C, Pereira A, et al. (2018) Influence of thickness and contact area on the performance of PDMS-based triboelectric nanogenerators. arXiv preprint arXiv: 180310070. Available at: https://arxiv.org/abs/1803.10070
14. Gooding DM · 2011 · 1
15. 10.1016/j.arth.2013.10.02010.1016/j.arth.2013.10.020 ↗
16. 10.1016/j.nanoen.2014.03.00910.1016/j.nanoen.2014.03.009 ↗
17. 10.1088/1361-6439/ab6c7410.1088/1361-6439/ab6c74 ↗
18. 10.1021/nn405209u10.1021/nn405209u ↗
19. 10.1088/1361-665X/aaf3f110.1088/1361-665X/aaf3f1 ↗
20. 10.1016/j.jsv.2017.11.03610.1016/j.jsv.2017.11.036 ↗
21. 10.1109/MWSCAS.2019.888497210.1109/MWSCAS.2019.8884972 ↗
22. 10.1016/j.nanoen.2016.06.04910.1016/j.nanoen.2016.06.049 ↗
23. 10.1088/0960-1317/24/3/03501710.1088/0960-1317/24/3/035017 ↗
24. 10.1016/0021-9290(95)00124-710.1016/0021-9290(95)00124-7 ↗
25. 10.1021/am501807210.1021/am5018072 ↗
26. 10.1016/j.joca.2012.11.00810.1016/j.joca.2012.11.008 ↗
27. 10.1002/jor.2147710.1002/jor.21477 ↗
28. 10.1016/j.jbiomech.2010.03.04610.1016/j.jbiomech.2010.03.046 ↗
29. 10.1021/nn501983s10.1021/nn501983s ↗
30. 10.1002/anie.20130043710.1002/anie.201300437 ↗
31. 10.1109/SAS.2012.616627310.1109/SAS.2012.6166273 ↗
32. 10.1002/anie.20070181210.1002/anie.200701812 ↗
33. 10.1016/j.arth.2016.03.04610.1016/j.arth.2016.03.046 ↗
34. 10.1016/j.nanoen.2014.11.03410.1016/j.nanoen.2014.11.034 ↗
35. 10.1109/TED.2014.237772810.1109/TED.2014.2377728 ↗
36. 10.1007/s11999-010-1399-010.1007/s11999-010-1399-0 ↗
37. 10.1109/TMECH.2005.85248210.1109/TMECH.2005.852482 ↗
38. Roche M · Orthopedic Clinics · 2014 · 45 · 157
39. 10.1016/S0140-3664(02)00248-710.1016/S0140-3664(02)00248-7 ↗
40. 10.1109/TMECH.2018.279418210.1109/TMECH.2018.2794182 ↗
41. 10.1093/eurheartj/sum07110.1093/eurheartj/sum071 ↗
42. 10.1016/j.nanoen.2014.07.00610.1016/j.nanoen.2014.07.006 ↗
43. 10.1021/acs.jpcc.5b0036010.1021/acs.jpcc.5b00360 ↗
44. 10.1021/acsnano.5b0356710.1021/acsnano.5b03567 ↗
45. 10.1115/1.402642810.1115/1.4026428 ↗
46. 10.1021/nl400738p10.1021/nl400738p ↗
47. 10.1021/nn505436510.1021/nn5054365 ↗
48. 10.1002/adma.20130530310.1002/adma.201305303 ↗
49. 10.1039/C4FD00159A10.1039/C4FD00159A ↗
50. 10.1002/aenm.20160050510.1002/aenm.201600505 ↗
51. 10.1002/adfm.20150042810.1002/adfm.201500428 ↗
52. 10.1039/c3ee41063c10.1039/c3ee41063c ↗
53. 10.1021/nl304568410.1021/nl3045684 ↗
54. 10.1016/j.nanoen.2013.12.01610.1016/j.nanoen.2013.12.016 ↗
55. 10.1021/acsnano.6b0269310.1021/acsnano.6b02693 ↗
56. 10.1021/am504110u10.1021/am504110u ↗
57. 10.1021/nl400105310.1021/nl4001053 ↗
58. 10.1038/srep2223310.1038/srep22233 ↗
59. 10.1038/ncomms1098710.1038/ncomms10987 ↗