journal article·2021-03

Two degree of freedom vibration based electromagnetic energy harvester for bridge health monitoring system

Muhammad Masood Ahmad, Farid Ullah Khan

Publisher page

Abstract

This paper presents an electromagnetic energy harvester to extract low frequency and low acceleration vibration energy available in a bridge environment. The developed harvester is a multi-mode oscillator with dual electromagnetic transduction mechanisms. The harvester consists of two cantilever beams. The first cantilever beam is split into two equal pieces along its length and the second beam placed in between them coming back to the fixed end and attached at outer end to the first beam. This way instead of a long conventional cantilever beam a compact harvester is fabricated. Two magnets as proof masses are attached to each free end of the beam making it a two degree of freedom system (2-DOF). The magnets are positioned to oscillate inside hand wound coils during operation. An analytical model was developed and COMSOL multiphysics was used to simulate the mode shapes of the harvester. The mathematical model was simulated for open circuit voltage in MATLAB and showed closely matching results with the experimental values. The harvester is characterized in lab for its performance under sinusoidal vibrations at low frequency (3 Hz–15 Hz) and low acceleration (0.01–0.09 g) levels. The 2-DOF harvester has two resonant frequencies of 4.4 Hz and 5.5 Hz and a volume of 333 cm 3 . It produces maximum voltage of 0.6 V at first resonance on coil-1 and maximum voltage of 1.2 V on coil-2 at second resonance at 0.09 g. At acceleration of 0.09 g the harvester produced 2.51 mW at first resonant frequency and 10.7 mW at second resonance. Moreover, the AC output voltage of the harvester is rectified to DC voltage by a three-stage Cockcroft-Walton multiplier type circuit. The DC power output at 0.05 g was 0.939 mW at first resonance and 0.956 mW at second resonance while maximum voltages of 5.4 V on coil-1 and 4 V on coil-2 were produced.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Innovative Energy Harvesting Technologies · Structural Health Monitoring Techniques · Wireless Power Transfer Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechatronics, University of Engineering and Technology Peshawar, Peshawar, KP, Pakistan

References (56)

Show source-provided references
1. 10.1061/(ASCE)0733-9399(1985)111:4(463)10.1061/(ASCE)0733-9399(1985)111:4(463) ↗
2. Ashraf K, Khir MM, Dennis J, et al. (2012) An energy pumping frequency increased vibration energy harvester. PowerMEMS 2012, Atlanta, GA, 2–5 December.
3. 10.1016/j.sna.2013.03.02610.1016/j.sna.2013.03.026 ↗
4. 10.1155/2019/568251710.1155/2019/5682517 ↗
5. 10.1155/2017/608430910.1155/2017/6084309 ↗
6. 10.1061/(ASCE)1084-0702(2003)8:3(162)10.1061/(ASCE)1084-0702(2003)8:3(162) ↗
7. 10.1016/j.ymssp.2018.01.00710.1016/j.ymssp.2018.01.007 ↗
8. 10.1016/j.ymssp.2016.01.01610.1016/j.ymssp.2016.01.016 ↗
9. 10.1016/j.engstruct.2008.01.01310.1016/j.engstruct.2008.01.013 ↗
10. 10.1016/j.autcon.2011.06.00810.1016/j.autcon.2011.06.008 ↗
11. Flanigan KA · 2017
12. Galchev T, McCullagh J, Peterson R, et al. (2010) A vibration harvesting system for bridge health monitoring applications. In: Proc. PowerMEMS . http://cap.ee.ic.ac.uk/pdm97/powermems/2010/oral-pdfs/179_Galchev_139.pdf
13. 10.5703/128828431403210.5703/1288284314032 ↗
14. 10.1063/1.486721610.1063/1.4867216 ↗
15. 10.1016/j.sna.2013.12.03310.1016/j.sna.2013.12.033 ↗
16. 10.1111/j.1467-8667.2012.00781.x10.1111/j.1467-8667.2012.00781.x ↗
17. 10.1007/s13349-015-0114-y10.1007/s13349-015-0114-y ↗
18. Jang S, Jo H, Cho S, et al. (2010) Structural Health Monitoring of a Cable-Stayed Bridge Using Smart Sensor Technology: Deployment and Evaluation. Smart Structures and Systems 6(5-6): 439–459.10.12989/sss.2010.6.5_6.439 ↗
19. Kala J · International Journal of Engineering and Applied Sciences · 2009 · 5 · 269
20. 10.1016/j.ijmecsci.2016.09.02910.1016/j.ijmecsci.2016.09.029 ↗
21. Kelly SG · 2012
22. 10.1007/s00542-013-1938-110.1007/s00542-013-1938-1 ↗
23. 10.1155/2014/74258010.1155/2014/742580 ↗
24. 10.1155/2018/384968310.1155/2018/3849683 ↗
25. 10.1109/IPSN.2007.437968510.1109/IPSN.2007.4379685 ↗
26. Kwon D-S, Ko H-J, Kim J (2017) Piezoelectric and electromagnetic hybrid energy harvester using two cantilevers for frequency up-conversion. In: 2017 IEEE 30th International Conference on Micro Electro Mechanical Systems (MEMS), Las Vegas, NV, USA. New Jersey, US: IEEE. https://ieeexplore.ieee.org/xpl/conhome/7852393/proceeding10.1109/MEMSYS.2017.7863336 ↗
27. 10.1063/1.486913010.1063/1.4869130 ↗
28. 10.1088/0964-1726/22/5/05500710.1088/0964-1726/22/5/055007 ↗
29. 10.1016/j.jsv.2014.06.04610.1016/j.jsv.2014.06.046 ↗
30. 10.1007/s00542-015-2440-810.1007/s00542-015-2440-8 ↗
31. 10.1063/1.491971110.1063/1.4919711 ↗
32. 10.1016/j.sna.2016.06.03310.1016/j.sna.2016.06.033 ↗
33. 10.1016/j.sna.2012.01.03310.1016/j.sna.2012.01.033 ↗
34. 10.1155/2017/493174910.1155/2017/4931749 ↗
35. Lu Q, Loong C, Chang C-C, et al. (2014) Scavenging vibration energy from seismically isolated bridges using an electromagnetic harvester. In: Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems 2014, 10 April 2014. https://doi.org/10.1117/12.204483910.1117/12.2044839 ↗
36. 10.1016/j.ymssp.2011.06.01110.1016/j.ymssp.2011.06.011 ↗
37. 10.1155/2015/28613910.1155/2015/286139 ↗
38. 10.1016/j.sna.2014.07.00310.1016/j.sna.2014.07.003 ↗
39. Neitzel F · 2011 · 90 · 331
40. 10.1016/j.sna.2014.03.03710.1016/j.sna.2014.03.037 ↗
41. 10.1088/0964-1726/22/9/09501910.1088/0964-1726/22/9/095019 ↗
42. Rastegar J, Pereira C, Nguyen H-L (2006) Piezoelectric-based power sources for harvesting energy from platforms with low-frequency vibration. In: Structures and Materials 2006: Industrial and Commercial Applications of Smart Structures Technologies, 24 March 2006, 617101. https://doi.org/10.1117/12.657464.10.1117/12.657464 ↗
43. 10.1016/j.engstruct.2010.02.03310.1016/j.engstruct.2010.02.033 ↗
44. 10.1109/JSEN.2009.201933310.1109/JSEN.2009.2019333 ↗
45. 10.1088/1742-6596/557/1/01213510.1088/1742-6596/557/1/012135 ↗
46. 10.1177/1045389X1351900310.1177/1045389X13519003 ↗
47. 10.1088/0960-1317/18/11/11502110.1088/0960-1317/18/11/115021 ↗
48. Sumitro S, Okamoto T, Matsui Y, et al. (2001) Long span bridge health monitoring system in Japan. In: Health Monitoring and Management of Civil Infrastructure Systems, 3 August 2001. https://doi.org/10.1117/12.43562810.1117/12.435628 ↗
49. 10.1016/j.ceramint.2017.05.25710.1016/j.ceramint.2017.05.257 ↗
50. 10.2749/10168669778049456310.2749/101686697780494563 ↗
51. 10.1016/j.apenergy.2016.12.16810.1016/j.apenergy.2016.12.168 ↗
52. 10.1177/1045389X1245725410.1177/1045389X12457254 ↗
53. 10.1177/1045389X1245725410.1177/1045389X12457254 ↗
54. 10.1177/1045389X1454149410.1177/1045389X14541494 ↗
55. 10.1088/1361-665X/aa791d10.1088/1361-665X/aa791d ↗
56. 10.1109/JSEN.2010.205900710.1109/JSEN.2010.2059007 ↗