An integrated multilayer ceramic piezoelectric micropump for microfluidic systems
Source abstract
Abstract
A package-level peristaltic piezoelectric micropump has been designed and fabricated in utilizing multilayer ceramic fabrication methods. The device was fabricated using commercially available low-temperature cofired ceramic materials and a custom-designed low-temperature cofired ceramic compatible piezoelectric ceramic composition. The assembled multilayer pump structure was sintered in single cofiring step. Performance testing resulted in observed unloaded bidirectional flow rates of 450 µL/min and a blocking pressure of 1.4 kPa when the pump was operated at a voltage of 100 V pp (with a phase difference of 120°) with a frequency of 100 Hz. It was further shown that incorporation of diffuser elements into the microfluidic interconnects was used to increase the blocking pressure capabilities at the expense of flow rate and bidirectional flow characteristics. Alternatively, by maintaining a uniform channel width but varying channel cross section width over height ratio ( W/ H), an unloaded flow rate of 630 µL/min with an enhancement of blocking pressure (1.55 kPa) was achieved for W/ H = 3 (and the same drive conditions as above). The resulting multilayer ceramic-based piezoelectric micropump offers a compact planar pump design, with significant performance advantages, and design flexibility compared to competing micropump technologies.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Microfluidic and Capillary Electrophoresis Applications · Innovative Microfluidic and Catalytic Techniques Innovation · Microfluidic and Bio-sensing Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Center for Power Electronics Systems, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA
Department of Chemical and Materials Engineering, University of Kentucky, Lexington, KY, USA
References (36)
Show source-provided references
1. Baker A, Randall C, Stewart R, (2006) Fabrication of a multilayered low-temperature cofired ceramic micro-plasma-generating device. International Journal of Applied Ceramic Technology 3(6): 413–418. Available at: http://doi.wiley.com/10.1111/j.1744-7402.2006.02104.x10.1111/j.1744-7402.2006.02104.x ↗
2. Bilitewski U, Genrich M, Kadow S, (2003) Biochemical analysis with microfluidic systems. Analytical and Bioanalytical Chemistry 377(3): 556–569. Available at: http://www.ncbi.nlm.nih.gov/pubmed/1450467710.1007/s00216-003-2179-4 ↗
3. Chia BT, Liao H-H, Yang Y-J (2011) A novel thermo-pneumatic peristaltic micropump with low temperature elevation on working fluid. Sensors and Actuators A: Physical 165(1): 86–93. Available at: http://linkinghub.elsevier.com/retrieve/pii/S092442471000081610.1016/j.sna.2010.02.018 ↗
4. Chuan-Hu C, Santiago JG (2002) A planar electroosmotic micropump. Journal of Microelectromechanical Systems 11(6): 672–683. Available at: http://dx.doi.org/10.1109/JMEMS.2002.80505510.1109/JMEMS.2002.805055 ↗
5. Erickson D, Li D (2004) Integrated microfluidic devices. Analytica Chimica Acta 507: 11–26. Available at: http://www.sciencedirect.com/science/article/pii/S000326700301226110.1016/j.aca.2003.09.019 ↗
6. Golonka LJ, Roguszczak H, Zawada T, (2005) LTCC based microfluidic system with optical detection. Sensors and Actuators B: Chemical 111–112: 396–402. Available at: http://linkinghub.elsevier.com/retrieve/pii/S092540050500305910.1016/j.snb.2005.03.065 ↗
7. Gómez-de Pedro S, Puyol M, Alonso-Chamarro J (2010) Continuous flow synthesis of nanoparticles using ceramic microfluidic devices. Nanotechnology 21(41): 415603. Available at: http://www.ncbi.nlm.nih.gov/pubmed/2084432510.1088/0957-4484/21/41/415603 ↗
8. Gongora-Rubio MR, Espinoza-Vallejos P, Sola-Laguna L, (2001) Overview of low temperature co-fired ceramics tape technology for meso-system technology (MsST). Sensors and Actuators 89: 222–241. Available at: http://dx.doi.org/10.1016/S0924-4247(00)00554-910.1016/S0924-4247(00)00554-9 ↗
9. Graf NJ, Bowser MT (2008) A soft-polymer piezoelectric bimorph cantilever-actuated peristaltic micropump. Lab on a Chip 8(10): 1664–1670. Available at: http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=2739037&tool=pmcentrez&rendertype=abstract10.1039/b805252b ↗
10. Hsu Y-C, Hsu J-L, Le NB (2009) An experimental and numerical investigation into the effects of the PZT actuator shape in polymethylmethacrylate (PMMA) peristaltic micropumps. Microsystem Technologies 15(4): 565–571. Available at: http://www.springerlink.com/index/10.1007/s00542-008-0761-610.1007/s00542-008-0761-6 ↗
11. Ibáñez-García N, Alonso J, Martínez-Cisneros CS, (2008) Green-tape ceramics. New technological approach for integrating electronics and fluidics in microsystems. TrAC: Trends in Analytical Chemistry 27(1): 24–33. Available at: http://linkinghub.elsevier.com/retrieve/pii/S016599360700241510.1016/j.trac.2007.11.002 ↗
12. Jang L-S, Kan W-H (2007) Peristaltic piezoelectric micropump system for biomedical applications. Biomedical Microdevices 9(4): 619–626. Available at: http://www.ncbi.nlm.nih.gov/pubmed/1750588610.1007/s10544-007-9075-1 ↗
13. Jang L-S, Li Y-J, Lin S-J, (2007) A stand-alone peristaltic micropump based on piezoelectric actuation. Biomedical Microdevices 9(2): 185–194. Available at: http://www.ncbi.nlm.nih.gov/pubmed/1716070510.1007/s10544-006-9020-8 ↗
14. Jang L-S, Shu K, Yu Y-C, (2009) Effect of actuation sequence on flow rates of peristaltic micropumps with PZT actuators. Biomedical Microdevices 11(1): 173–181. Available at: http://www.ncbi.nlm.nih.gov/pubmed/1882101610.1007/s10544-008-9222-3 ↗
15. Kang H-J, Choi B (2011) Development of the MHD micropump with mixing function. Sensors and Actuators A: Physical 165(2): 439–445. Available at: http://linkinghub.elsevier.com/retrieve/pii/S092442471000494210.1016/j.sna.2010.11.011 ↗
16. Koch M, Evans AGR, Brunnschweiler A (1998) The dynamic micropump driven with a screen printed PZT actuator. Journal of Micromechanics and Microengineering 8(2): 119–122. Available at: http://iopscience.iop.org/0960-1317/8/2/01910.1088/0960-1317/8/2/019 ↗
17. Laser DJ, Santiago JG (2004) A review of micropumps. Journal of Micromechanics and Microengineering 14(6): R35–R64. Available at: http://stacks.iop.org/0960-1317/14/i=6/a=R01?key=crossref.137857bfcf5ea513064ec576b484af8f10.1088/0960-1317/14/6/R01 ↗
18. 10.1109/SENSOR.2003.121527510.1109/SENSOR.2003.1215275 ↗
19. Lim CW, He LH, Soh AK (2001) Three-dimensional electromechanical response of a parallel piezoelectric bimorph. International Journal of Solids and Structures 38: 2833–2849. Available at: http://dx.doi.org/10.1016/S0020-7683(00)00186-410.1016/S0020-7683(00)00186-4 ↗
20. Liu RH, Yang J, Lenigk R, (2004) Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection. Analytical Chemistry 76(7): 1824–1831. Available at: http://www.ncbi.nlm.nih.gov/pubmed/1505363910.1021/ac0353029 ↗
21. Mamanee W, Tuantranont A, Afzulpurkar NV, (2006) PDMS based thermopnuematic peristaltic micropump for microfluidic systems. In: International MEMS conference 2006 (eds Tay FEH, Jianmin M, Bergstrom J,) Singapore, 9 –12 May 2006, pp. 564–569. Available at: http://iopscience.iop.org/1742-6596/34/1/093/10.1088/1742-6596/34/1/093 ↗
22. 10.1016/0021-9673(92)80293-410.1016/0021-9673(92)80293-4 ↗
23. Olsson A, Enoksson P (1997) Micromachined flat-walled valveless diffuser pumps. Journal of Microelectromechanical Systems 6(2): 161–166. Available at: http://dx.doi.org/10.1109/84.58579410.1109/84.585794 ↗
24. Olsson A, Stemme G, Stemme E (2000) Numerical and experimental studies of flat-walled diffuser elements for valve-less micropumps. Sensors and Actuators A: Physical 84(1–2): 165–175. Available at: http://linkinghub.elsevier.com/retrieve/pii/S092442479900320910.1016/S0924-4247(99)00320-9 ↗
25. Paul PH, Arnold DW, Rakestraw DJ (1998) Electrokinetic generation of high pressures using porous microstructures. In: Micro total analysis systems ’98 conference, Banff, AB, Canada, 13–16 October 1998, pp. 49–52. Available at: http://link.springer.com/chapter/10.1007/978-94-011-5286-0_1110.1007/978-94-011-5286-0_11 ↗
26. Satarkar NS, Zhang WL, Eitel RE, (2009) Magnetic hydrogel nanocomposites as remote controlled microfluidic valves. Lab on a Chip 9(12): 1773–1779. Available at: http://www.ncbi.nlm.nih.gov/pubmed/1949546210.1039/b822694f ↗
27. Smits JG (1990) Piezoelectric micropump with three valves working peristaltically. Sensors and Actuators A: Physical A21–A23: 203–206. Available at: http://www.sciencedirect.com/science/article/pii/092442479085039710.1016/0924-4247(90)85039-7 ↗
28. Sobocinski M, Juuti J, Jantunen H, (2009) Piezoelectric unimorph valve assembled on an LTCC substrate. Sensors and Actuators A: Physical 149(2): 315–319. Available at: http://linkinghub.elsevier.com/retrieve/pii/S092442470800580310.1016/j.sna.2008.11.025 ↗
29. Thelemann T, Thust H, Hintz M (2002) Using LTCC for microsystems. Microelectronics International 19(3): 19–23. Available at: http://dx.doi.org/10.1108/1356536021044500510.1108/13565360210445005 ↗
30. Woias P (2005) Micropumps—past, progress and future prospects. Sensors and Actuators B: Chemical 105(1): 28–38. Available at: http://linkinghub.elsevier.com/retrieve/pii/S092540050400108X10.1016/S0925-4005(04)00108-X ↗
31. Yang W · 2002
32. Yoon JS, Choi JW, Lee IH, (2007) A valveless micropump for bidirectional applications. Sensors and Actuators A: Physical 135(2): 833–838. Available at: http://linkinghub.elsevier.com/retrieve/pii/S092442470600548610.1016/j.sna.2006.08.017 ↗
33. Zeng S, Chuan-Hua C, Mikkelsen JC, (2001) Fabrication and characterization of electroosmotic micropumps. Sensors and Actuators B: Chemical 79(2–3): 107–114. Available at: http://linkinghub.elsevier.com/retrieve/pii/S092540050100855310.1016/S0925-4005(01)00855-3 ↗
34. Zhang W, Eitel RE (2011) Low-temperature sintering and properties of 0.98PZT-0.02SKN ceramics with LiBiO 2 and CuO addition. Journal of the American Ceramic Society 94(10): 3386–3390. Available at: http://doi.wiley.com/10.1111/j.1551-2916.2011.04504.x10.1111/j.1551-2916.2011.04504.x ↗
35. 10.1111/j.1744–7402.2011.02747.x10.1111/j.1744–7402.2011.02747.x ↗
36. Zhong J, Yi M, Bau HH (2002) Magneto hydrodynamic (MHD) pump fabricated with ceramic tapes. Sensors and Actuators A: Physical 96(1): 59–66. Available at: http://dx.doi.org/10.1016/S0924-4247(01)00764-610.1016/S0924-4247(01)00764-6 ↗