Effects of self heating when using a continuous bridge voltage for strain gauging epoxy models
Source abstract
Abstract
One source of concern when strain gauging epoxy materials, is that if the gauges are continuously energised at high power densities, then the heat generated by the strain gauges will cause large apparent strains and will reduce the modulus of the underlying material. The magnitude and significance of the heating effect are discussed and methods of reducing this effect are indicated.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Smart Materials for Construction
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (12)
Show source-provided references
1. 10.1111/j.1475-1305.1974.tb00075.x10.1111/j.1475-1305.1974.tb00075.x ↗
2. Nickola W. E. · 1978
3. ‘Strain and temperature measurements on epoxy resin models’
4. 10.1007/BF0232608710.1007/BF02326087 ↗
5. 10.1111/j.1475-1305.1972.tb01754.x10.1111/j.1475-1305.1972.tb01754.x ↗
6. Epelle O. B. · 1970 · 419
7. Bray A.andLevi R. ‘Discussion of item 6 above 4th International Conference of Experimental Stress Analysis Cambridqe U.K. (1970).
8. 10.1243/03093247V03317610.1243/03093247V033176 ↗
9. 10.1007/BF0232740710.1007/BF02327407 ↗
10. ‘Embedded foil strain gauges for the determination of internal stress’
11. 10.1111/j.1475-1305.1975.tb00160.x10.1111/j.1475-1305.1975.tb00160.x ↗
12. 10.1007/BF0232576310.1007/BF02325763 ↗