journal article·2016-12-10

Study on rectangular concrete-filled steel tubes with unequal wall thickness

Yang Zhang, Chen-Jiang Yu, Guang-Yuan Fu, Bing Chen, She-Xu Zhao, Si-Ping Li

Steel and Composite Structures· Volume 22· Issue 5
Publisher page

Abstract

Rectangular concrete-filled steel tubular columns with unequal wall thickness were investigated in the paper. The physical centroid, the centroidal principal axes of inertia, and the section core were given. The generalized bending formula and the generalized eccentric compression formula were deduced, and the equation of the neutral axis was also provided. The two rectangular concrete-filled steel tubular stub specimens subjected to the compression load on the physical centroid and the geometric centroid respectively were tested to verify the theoretical formulas.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Load-Bearing Analysis · Structural Engineering and Vibration Analysis · Engineering Structural Analysis Methods

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.