Experimental investigation of the behaviour of a steel sub-frame under a natural fire
Source abstract
Abstract
This paper details a testing facility ("NATURAL FIRE FACILITY") that allows closely-controlled experimental testing on full-scale sub-frames while reproducing the spatially transient temperature conditions measured in real fires. Using this test facility, an experimental investigation of six steel sub-frames under a natural fire was carried out at the Department of Civil Engineering of the University of Coimbra. The main objective of these tests was to provide insight into the influence of these connection types on the behaviour of steel sub-structures under fire. The experimental layout is defined by two thermally insulated HEA300 columns and an unprotected IPE300 beam with 5.7 m span, supporting a composite concrete slab. Beam-to-column connections are representative of the most common joint type used on buildings: welded joints and extended, flush and partial depth plate. Finally, the available results are presented and discussed: evolution of the steel temperature; development of displacements and local deformations and failure modes on the joints zone.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Fire effects on concrete materials · Structural Load-Bearing Analysis · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (6)
Show source-provided references
1. Proc. Instn Civil Engrs, Structures & Buildings · 1997 · 122 · 41010.1680/istbu.1997.29830 ↗
2. J. Constr. Steel Res. · 2002 · 58 · 121110.1016/S0143-974X(01)00062-1 ↗
3. J. Constr. Steel Res. · 2002 · 57 · 1169
4. Steel Compos. Struct. · 2005 · 6 · 485
5. Fire Safety J. · 2006 · 41 · 50910.1016/j.firesaf.2006.05.006 ↗
6. J. Constr. Steel Res. · 2003 · 59 · 17910.1016/S0143-974X(02)00023-8 ↗