journal article·2016-11

Radiative and hygrothermal properties of flax/viscose spunlaced nonwovens

Thibaut Colinart, Thomas Pierre

Journal of Industrial Textiles· Volume 46· Issue 4
Publisher page

Abstract

Biobased fabrics are now getting widely used as solar shading for managing solar gain and daylight management and reducing building peak load and annual energy consumption of existing buildings. This work proposes to characterize five spunlaced nonwovens made of 65% of flax and 35% of viscose with different grammage. Radiative properties (transmissivity, reflectivity and absorptivity) are evaluated not only over the sun’s spectrum, but also over UV, visible and IR spectra. In addition, hygrothermal properties, such as thermal resistance, specific heat capacity or water vapor resistance, are also evaluated. Results indicate that these nonwovens present low transmittivity, which is interesting in the view of managing solar gain. Furthermore, it was found that radiative properties are mainly influenced by nonwoven’s thickness and porosity, as well the relative humidity. Lastly, hygrothermal properties (thermal resistance, thermal conductivity and water vapor resistance) are impacted mainly by porosity.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Textile materials and evaluations · Building Energy and Comfort Optimization · Thermal Radiation and Cooling Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Univ. Bretagne-Sud, Lorient, France

References (41)

Show source-provided references
1. Beck W, Dolmans D, Dutoo G, et al. Seppänen O, Solar shading—How to integrate solar shading in sustainable buildings. Wouter Beke REHVA Ed, 2010.
2. Dubois M-C. Solar shading and building energy use: A literature review . Report TABK—97/3049, Lund Institute of Technology, Dept. of Building Science, Lund, Sweden, 1997.
3. 10.1016/j.solener.2006.06.01510.1016/j.solener.2006.06.015 ↗
4. 10.1016/j.buildenv.2010.05.01310.1016/j.buildenv.2010.05.013 ↗
5. 10.1016/j.buildenv.2010.05.01310.1016/j.buildenv.2010.05.013 ↗
6. Barnaby CS · ASHRAE Transact · 2009 · 115 · 1
7. 10.1007/s12273-013-0137-410.1007/s12273-013-0137-4 ↗
8. Kotey NA · ASHRAE Transact · 2009 · 115 · 1
9. 10.1533/joti.2005.029810.1533/joti.2005.0298 ↗
10. Sen T · Int J Innovat Manage Technol · 2011 · 2 · 192
11. 10.1016/j.polymertesting.2007.08.00310.1016/j.polymertesting.2007.08.003 ↗
12. 10.1080/15440478.2013.86178110.1080/15440478.2013.861781 ↗
13. 10.3763/aber.2008.020710.3763/aber.2008.0207 ↗
14. Kotey NA · ASHRAE Transact · 2009 · 15 · 1
15. Pailthrope M · Textile Horizons · 1996 · 16 · 11
16. 10.1016/S0027-5107(98)00190-010.1016/S0027-5107(98)00190-0 ↗
17. Gabrijelčič H · Fibers Textiles East Europe · 2009 · 17 · 46
18. 10.1046/j.1365-4362.1997.00046.x10.1046/j.1365-4362.1997.00046.x ↗
19. Algaba I · AATCC Rev · 2004 · 4 · 26
20. 10.1111/j.1751-1097.2008.00439.x10.1111/j.1751-1097.2008.00439.x ↗
21. 10.1533/9781845696443.30910.1533/9781845696443.309 ↗
22. Rowe T. Interior textiles: design and developments . 1st ed. Boca Raton, FL: Woodhead Publishing Limited, 2009.10.1533/9781845696870 ↗
23. 10.4028/www.scientific.net/AMR.627.40410.4028/www.scientific.net/AMR.627.404 ↗
24. 10.1016/j.indcrop.2013.06.01210.1016/j.indcrop.2013.06.012 ↗
25. 10.1016/j.indcrop.2014.07.01510.1016/j.indcrop.2014.07.015 ↗
26. Russel J. Handbook of nonwovens . Cambridge, UK: CRC Press, 2007.10.1201/9781439823453 ↗
27. Siegel R · 1992
28. 10.1007/s10973-013-3013-710.1007/s10973-013-3013-7 ↗
29. 10.1016/0020-0891(89)90014-610.1016/0020-0891(89)90014-6 ↗
30. 10.1016/0927-0248(93)90037-410.1016/0927-0248(93)90037-4 ↗
31. Crews PC · Text Chem Color · 1999 · 31 · 17
32. Das BR · Open Textile J · 2010 · 3 · 14
33. Ganem C and Coch H. Solar and heat protection techniques. Evaluation and design recommendations for different types of fabric awnings. A: Passive and low energy cooling for the built environment. In: PALENC 2010 conference , Rhodes Island, Greece, 29 September–1 October 2010, pp.1–9.
34. 10.1007/s00340000030010.1007/s003400000300 ↗
35. 10.1177/00405175990690081010.1177/004051759906900810 ↗
36. 10.1016/S1290-0729(03)00074-710.1016/S1290-0729(03)00074-7 ↗
37. 10.1016/0019-1035(68)90083-310.1016/0019-1035(68)90083-3 ↗
38. 10.1007/s10765-012-1386-710.1007/s10765-012-1386-7 ↗
39. 10.1080/00405000.2014.91278310.1080/00405000.2014.912783 ↗
40. 10.1088/0957-0233/18/5/01610.1088/0957-0233/18/5/016 ↗
41. Kumaran K. International energy agency, condensation and energy – catalogue of material properties, Report Annex 24, Vol. 3 in Energy Conservation in Buildings, 1996.