journal article·2022-06Open access

Development of fabric electrode for bio-potential signal acquisition in wearable health monitoring and effect of perspiration on signal acquisition

M. S. Yogendra, M.V. Mallikarjuna Reddy, S.N. Kartik, K. Mohanvelu, F.V. Varghese, TM. Kotresh

Journal of Industrial Textiles· Volume 51· Issue 2_suppl

Abstract

Development of a gel-free bio-potential electrode for the wearable health monitoring applications is a challenging goal. A conductive fabric electrode can replace the traditional conductive gel electrode. This paper describes the development of a conductive fabric electrode with regard to its potential use for electrocardiogram (ECG) acquisition. Since direct contact between the conductive fabric and human skin will be involved, an investigation on the effect of perspiration on the electrical conductivity of fabric is critical. Hence, the developed electrode was treated with alkaline (pH=8.0) and acidic (pH=4.3) perspiration for 3, 8 and 40 h to study the effect of perspiration on the conductivity and surface morphology. The acquired ECG signals were analysed with respect to morphology and frequency distribution. Conductivity tests were carried out on the perspiration-treated test electrodes by two probe method and surface resistivity meter. The ECG signals of volunteers were also recorded. The results showed a slight decrease in conductivity but without affecting the morphology and the quality of ECG signal. Leached silver content in the acid perspiration-treated solution was found to be 0.117 ppm as determined by Atomic absorption spectroscopy. The result shows that soft conducting textile materials can indeed be used as an electrode for ECG acquisition. This is a novel type of gel-free fabric electrode for long term wearable health monitoring applications including space application.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Conducting polymers and applications · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Textile Chemistry, Defence Bioengineering and Electromedical Laboratory, Bengaluru, India

Ministry of Defence, DEBEL, DRDO, Bengaluru, India

Protective Clothing Technology, DEBEL, Bengaluru, India

PETG, DEBEL, Bengaluru, India

References (28)

Show source-provided references
1. Muthu Kumar N · J Textile Apparel, Technol Manag · 2014 · 8 · 1
2. Fernandes MS · Annu Int Conf IEEE Eng Med Biol Soc · 2010 · 2010 · 3503
3. 10.1117/12.54135010.1117/12.541350 ↗
4. 10.4236/jmmce.2014.2606110.4236/jmmce.2014.26061 ↗
5. 10.1109/CISP.2011.610073910.1109/CISP.2011.6100739 ↗
6. 10.1109/TITB.2005.85450610.1109/TITB.2005.854506 ↗
7. 10.1177/014233120708160510.1177/0142331207081605 ↗
8. 10.1109/ISSNIP.2007.449691710.1109/ISSNIP.2007.4496917 ↗
9. 10.3390/ma1110188710.3390/ma11101887 ↗
10. 10.3390/s12121690710.3390/s121216907 ↗
11. 10.1177/152808371877942710.1177/1528083718779427 ↗
12. 10.1177/152808371243806910.1177/1528083712438069 ↗
13. 10.1109/TITB.2005.85450510.1109/TITB.2005.854505 ↗
14. Mallikarjuna Reddy MV · J Instrum Soc India · 2011 · 41
15. Mankodiya K, Hassan YA, Hofmann UG. A Project Report on Textile Electrodes in a Body Belt to Capture and Process ECG Signals, Copenhagen, Denmark: Biomedizinische Technik, 2010, pp. 1–4.
16. 10.1007/s10570-015-0725-910.1007/s10570-015-0725-9 ↗
17. 10.4236/jmmce.2015.3302310.4236/jmmce.2015.33023 ↗
18. 10.1109/JTEHM.2018.286338810.1109/JTEHM.2018.2863388 ↗
19. 10.1016/j.jelekin.2012.04.00910.1016/j.jelekin.2012.04.009 ↗
20. AATCC. American Association of Textile Chemists and Colorists (AATCC) Technical Manual 2007; 82: 20.
21. Yokota M · 2006
22. ASHRAE · 1997
23. Michael B · 2004
24. Maryniak WA., Uehara T, Noras MA. “Surface Resistivity and Surface Resistance Measurements”, Application Note Number 1005. TREK, INC., 2013, p. 1.
25. 10.1177/152808371455368910.1177/1528083714553689 ↗
26. 10.1039/C2AN36422K10.1039/C2AN36422K ↗
27. EIA. Packaging Material Standards for ESD Sensitive Items, ANSI/EIA-541-1988. Rome, New York: Electrostatic Discharge Association, USA.
28. Bureau of Indian Standards IS