Analysis of suitability of elastomeric woven tape for strain sensor application and measurement of elbow angle
Source abstract
Abstract
Textile-based body worn sensors are preferred due to its comfortability for continuous monitoring of the body vital signs and kinematics. This research discusses the development and characterization of elastomeric tape for strain sensor application and is used for the measurement of elbow angle. The stress strain properties of commercially available elastomeric tapes have been analyzed for the selection of suitable specifications of elastomeric tape. The actual sensor has been developed with the help of narrow width tape loom by introducing the silver-coated nylon yarn in the middle of the tape structure. The effect of linear density of conductive yarn and number and strands of conductive threads used on sensitivity of the sensor was studied. The repeatability of the developed sensor was characterized by cyclic testing using Zwick tensile tester. Based on the results, polyester yarns were used as base threads along with rubber threads for the sensor development. It was found that sensor developed using finer yarn with six conductive threads has higher sensitivity. The developed sensor was integrated on to elbow sleeve and elbow angle measurement was done. The results of the developed tape sensor have been compared with the hospital goniometer for 10 male subjects. The results showed that the developed tape sensor is suitable for measuring the elbow angles up to 150°.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Innovative Energy Harvesting Technologies · Non-Invasive Vital Sign Monitoring
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
ABB Global Industries and Services Ltd, Bangalore, India
Department of Textile Technology, PSG College of Technology, Coimbatore, India
References (17)
Show source-provided references
1. De Rossi D · AUTEX Res J · 2003 · 3 · 18010.1515/aut-2003-030404 ↗
2. 10.1533/978184569293310.1533/9781845692933 ↗
3. 10.1557/mrs2003.17010.1557/mrs2003.170 ↗
4. 10.1063/1.474272810.1063/1.4742728 ↗
5. Pacelli M, Loriga G, Taccini N, et al. Sensing fabrics for monitoring physiological and biomechanical variables: e-textile solutions. In: Proceedings of the 3rd IEEE-EMBS international summer school and symposium on medical devices and biosensors 2006, Boston, USA, pp. 1–4.10.1109/ISSMDBS.2006.360082 ↗
6. 10.3390/s806371910.3390/s8063719 ↗
7. 10.1016/j.snb.2007.12.04110.1016/j.snb.2007.12.041 ↗
8. 10.1016/j.compstruct.2015.01.04610.1016/j.compstruct.2015.01.046 ↗
9. 10.1007/s10965-014-0469-510.1007/s10965-014-0469-5 ↗
10. 10.1007/s10965-015-0765-810.1007/s10965-015-0765-8 ↗
11. 10.1109/JSEN.2003.81577110.1109/JSEN.2003.815771 ↗
12. 10.1177/004051751245293110.1177/0040517512452931 ↗
13. 10.1177/004051750505687010.1177/0040517505056870 ↗
14. 10.1016/j.sna.2005.10.02610.1016/j.sna.2005.10.026 ↗
15. Kun Y, Guangli S, Liang Z, et al. Modeling the electrical property of 1 × 1 rib knitted fabrics made from conductive yarns. In: Proceedings of the second international conference on information and computing science (ICIC’2009) , Manchester, UK, pp. 382–385.10.1109/ICIC.2009.407 ↗
16. Li L, Au WM, Li Y, et al. Electromechanical analysis of conductive yarn knitted in plain knitting stitch under unidirectional extension. In: Proceedings of textile bioengineering and informatics symposium (TBIS 2008) , Hong Kong, pp. 793–797.
17. 10.3390/s13081111410.3390/s130811114 ↗