journal article·2019-09

New approach to evaluation of orthopaedic supports compression properties

L Muraliene, D Mikucioniene, G Laureckiene, M Brazaitis

Journal of Industrial Textiles· Volume 49· Issue 3
Publisher page

Abstract

This research was carried out to investigate behaviour of a knitted orthopaedic knee support in simulated real conditions as well as to propose a new approach to compression evaluation to preclude the possibility of any error in designing of new orthopaedic supports with exact compression level. Fully finished supports with all additional non-textile elements were analysed in this research. The support is defined as a corrective or orthopaedic item intended to grip or support any movable part of the body in the correct position and allows movement of that body part. The ways how textile material deforms under applied stresses as well as relaxation processes over the time play an important role in its processing and end use. A strong linear dependence between elongation of the support and compression generated by the support was found in this research. However, investigation on stress relaxation over the time showed that stress decrease over 36,000 s coincides with ranges of one full compression class, and the highest change (approx. 50%) in tensile force occurs during the first 100–200 s of relaxation. Such a change of compression has significant influence on the predictive pressure value generated by the compression garment and undermines its functionality. The obtained results indicate that a new approach to compression evaluation methodology must be adopted for theoretical compression value computation. Consequently, evaluation of the compression according to the tensile force must be performed not earlier than after at least 120 s relaxation.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Prosthetics and Rehabilitation Robotics · Ergonomics and Musculoskeletal Disorders · Musculoskeletal pain and rehabilitation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Kaunas University of Technology, Faculty of Mechanical Engineering and Design, Kaunas, Lithuania

Lithuanian Sports University, Institute of Sport Science and Innovations, Kaunas, Lithuania

Funding

Lietuvos Mokslo Taryba

References (18)

Show source-provided references
1. 10.1519/JSC.0b013e3181d3302510.1519/JSC.0b013e3181d33025 ↗
2. 10.1016/j.physbeh.2015.10.02710.1016/j.physbeh.2015.10.027 ↗
3. 10.1136/bjsm.2006.03375310.1136/bjsm.2006.033753 ↗
4. 10.1016/j.proeng.2010.04.07310.1016/j.proeng.2010.04.073 ↗
5. 10.5604/01.3001.0010.537410.5604/01.3001.0010.5374 ↗
6. Clark M · Template for Practice: Compression Hosiery in Lymhoedema · 2006 · 2
7. 10.1177/004051751664604110.1177/0040517516646041 ↗
8. 10.1002/app.2561710.1002/app.25617 ↗
9. 10.1177/152808370707235710.1177/1528083707072357 ↗
10. 10.1097/PHM.0b013e318114e41610.1097/PHM.0b013e318114e416 ↗
11. Kowalski K · Fibres Text Eastern Europe · 2012 · 20 · 98
12. Alisauskiene D · Fibres Text Eastern Europe · 2012 · 20 · 103
13. Oks B and Lyashenko I. Methods of calculation of local pressure of elastomer products. In: Proceedings of medical textiles’99 international conference. Cambridge Woodhead Publishing Limited, Bolton, England, 1999, pp. 82–91.10.1533/9781845693145.2.82 ↗
14. 10.1177/152808371666120510.1177/1528083716661205 ↗
15. Alisauskiene D · Fibres Text Eastern Europe · 2013 · 21 · 74
16. Maklevska E · Fibres Text Eastern Europe · 2006 · 14 · 111
17. 10.1097/00042728-200506000-0000110.1097/00042728-200506000-00001 ↗
18. 10.1515/aut-2017-001710.1515/aut-2017-0017 ↗