journal article·2017-07

Pressure distribution under different types of blood pressure measurement cuffs

Shenela Naqvi, Muhammad Dawood Husain, Prasad Potluri, Parthasarathi Mandal, Philip Lewis

Journal of Industrial Textiles· Volume 47· Issue 1
Publisher page

Abstract

The principal component of any non-invasive blood pressure measurement system is an inflatable cuff. Different types of fabrics are used for inflatable cuffs construction. In this study, sphygmomanometric blood pressure measurement using inflatable cuffs was simulated in Abaqus and validated through experimental results. The purpose of the simulation is to study the effect of variation in cuff fabric geometric and mechanical properties on pressure distribution and pressure transmission during blood pressure measurement by predicting the pressure at the interface of the blood pressure cuffs and a metal cylinder. Geometric and mechanical properties of the fabrics of four different cuff types were found experimentally. Interface pressure at the cuffs and metal cylinder surface was also found experimentally using Tekscan pressure sensing system for models validation. The results of the simulation showed that the interface pressure underneath the cuffs vary with variation in geometric and mechanical properties of their fabrics. The results of the simulation were found to be in good agreement with experimental findings. This research demonstrates that the pressure distribution under the cuffs is related to the cuffs' fabric geometric and mechanical properties. This means that variation in cuffs' fabric properties could ultimately incur variations in the blood pressure values of human subjects.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Non-Invasive Vital Sign Monitoring · Cardiovascular and exercise physiology · Thermoregulation and physiological responses

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Textile Engineering Department, NED University of Engineering and Technology, University Road, Karachi, Pakistan

School of Materials, The University of Manchester, Manchester, UK

School of Mechanical, Aerospace and Civil Engineering, The University of Manchester, Manchester, UK

Blood Pressure and Heart Research Centre, Stepping Hill Hospital, Stockport, UK

References (22)

Show source-provided references
1. Naqvi NH · 1998
2. TriCuff . http://www.ajmedical.se/english/tricuffeng.htm (accessed 9 February 2009).
3. Ledford J, et al. Bladderless blood pressure cuff . Google Patents, 2000.
4. 10.1291/hypres.24.35310.1291/hypres.24.353 ↗
5. Sen AK · 2000
6. 10.1038/sj.jhh.100168310.1038/sj.jhh.1001683 ↗
7. 10.1007/BF0236822510.1007/BF02368225 ↗
8. Kim HJ, Lee HC, Kim CH, et al. Blood flow and pressure in a brachial artery under cuff pressure. In: Industrial Electronics Society, IECON 2004, 30th Annual Conference of IEEE , 2 November 2004, Vol. 3, pp. 2973–2977. IEEE.10.1109/IECON.2004.1432284 ↗
9. 10.1109/10.50854010.1109/10.508540 ↗
10. Tekscan . www.tekscan.com/products (accessed 11 July 2011).
11. 10.1016/0141-5425(93)90014-P10.1016/0141-5425(93)90014-P ↗
12. 10.1016/0141-5425(86)90069-510.1016/0141-5425(86)90069-5 ↗
13. Shahidi AM · 2010
14. 10.1007/3-540-28804-X_510.1007/3-540-28804-X_5 ↗
15. Abaqus . ≤http://www.3ds.com/products-services/simulia/overview/≥ (accessed 4 March 2015).
16. 10.1201/978143982426910.1201/9781439824269 ↗
17. 10.1007/BF0244156810.1007/BF02441568 ↗
18. 10.1097/00004669-197801000-0001010.1097/00004669-197801000-00010 ↗
19. 10.1097/MBP.0b013e3283262f4510.1097/MBP.0b013e3283262f45 ↗
20. 10.1161/01.HYP.0000150859.47929.8e10.1161/01.HYP.0000150859.47929.8e ↗
21. 10.1097/00004872-198908000-0000210.1097/00004872-198908000-00002 ↗
22. 10.1038/ajh.2007.4510.1038/ajh.2007.45 ↗