Determination of heat transfer by radiation in textile fabrics by means of method with known emissivity of plates
Source abstract
Abstract
High thermal resistance of thermal insulating fabrics is a major factor in the decision to use them in protective apparel applications, sleeping bags and other functional textiles. New standards and new applications of fibre layers in industrial textiles require more accurate methods of testing of their thermal resistance and conductivity, which minimise the dependence of the measured parameters on the testing conditions, such as the temperature drop between the plates of testing instrument and infrared radiation properties of these plates. In this article, the use of a testing method based on two different temperature drops between the plates of the ALAMBETA testing instrument revealed that the portion of heat transferred by radiation through the tested woven fabrics reached 12–17%. From the second series of measurements it follows that decrease in surface emissivity of the plates of the mentioned testing instrument influences the level of heat transfer by radiation between the plates of the ALAMBETA testing instrument and may cause the changes in the experimentally determined thermal conductivity and thermal resistance of certain porous fabrics. These changes presented up to 8% for the studied non-woven fabrics with low density.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Textile materials and evaluations · Radiative Heat Transfer Studies · Thermoregulation and physiological responses
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Materials and Environmental Sciences, Institute of Textile Engineering and Polymers Materials, University of Bielsko-Biala, Bielsko-Biała, Poland
Faculty of Textile Engineering, Department of Textile Evaluation, Technical University of Liberec, Liberec, Czech Republic
References (13)
Show source-provided references
1. Gibson PW · J Eng Fibers Fabr · 2007 · 2 · 32
2. 10.1108/RJTA-08-01-2004-B00210.1108/RJTA-08-01-2004-B002 ↗
3. ISO 11092/Amd1:2012. Textiles – Physiological effects – Measurement of thermal and water-vapour resistance under steady-state conditions (sweating guarded-hotplate test) – Amendment 1.
4. DTC-25 Thermal Conductivity Meter ASTM E1530 Guarded Heat Flow Meter Method (http://thermophysical.tainstruments.com/instruments/thermal-conductivitymeters/dtc-25-thermal-conductivity-meter/).
5. Hes L. Thermal properties of nonwovens. Book of Proceedings, INDEX 1987 Congress, Geneva, 1987.
6. Sparrow EM · 1978
7. 10.1177/00405175830530120110.1177/004051758305301201 ↗
8. 10.1177/00405175030730100810.1177/004051750307301008 ↗
9. Hes L · 1989
10. 10.1080/0040500070158256210.1080/00405000701582562 ↗
11. 10.4188/transjtmsj.42.8_T12410.4188/transjtmsj.42.8_T124 ↗
12. 10.1177/00405175960660041010.1177/004051759606600410 ↗
13. Boguslawska – Baczek M and Hes L. The effect of moisture on thermal resistance and water vapour permeability of Nomex fabrics. J Mat Sci Eng A 2011; 1(3): 358–366.