The X-ray attenuation and the flexural properties of lead-free coated fabrics
Source abstract
Abstract
In this paper, tungsten, bismuth, tin, and copper powders were used as additives in the fabric coating to obtain lead-free and flexible x-ray shielding material. The X-ray attenuation and the flexural properties of the coated fabrics were investigated considering the medical protection requirements. The results showed that tungsten additives in silicone rubber coating had better attenuation ratios than the samples that contain tungsten–tin, bismuth, and tungsten–copper, at same additive volume ratios. Moreover, the increment of tungsten volume ratios in coating blend resulted in higher shielding performance at same effective thicknesses and the lower silicone rubber amount in coating lead to compose thinner and lighter fabrics for equal protection level. In addition to that, the samples with tungsten–tin, bismuth, and tungsten–copper showed remarkable attenuation properties, and the results were found to be coherent with the theoretical values. The flex resistance and the flexural rigidity of the samples with tungsten content were also investigated. The coated fabrics with different powder loadings and thicknesses showed good resistance against repetitive folding; on the other hand, the results showed that the increment of tungsten amount in the coating resulted in stiffer fabrics.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Radiation Shielding Materials Analysis · Polymer Nanocomposite Synthesis and Irradiation · Polymer Nanocomposites and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Istanbul Technical University, Inonu Caddesi, Istanbul, Turkey
References (25)
Show source-provided references
1. 10.1053/j.tvir.2010.03.00510.1053/j.tvir.2010.03.005 ↗
2. 10.1118/1.180976710.1118/1.1809767 ↗
3. 10.1118/1.278686110.1118/1.2786861 ↗
4. 10.2214/ajr.158.1.153076310.2214/ajr.158.1.1530763 ↗
5. 10.1093/rpd/ncr33010.1093/rpd/ncr330 ↗
6. Oyar O · Diagn Interv Radiol · 2012 · 18 · 147
7. Duran EB and Philips B. Rejection criteria for defects in lead apparel used for radiation protection of X-ray workers . Radiation Protection Services, British Columbia Centre for Disease Control (1 March 2003, Updated January 2014).
8. 10.1097/00004032-200105001-0000810.1097/00004032-200105001-00008 ↗
9. 10.1080/10420150.2011.55923710.1080/10420150.2011.559237 ↗
10. Sastri VR. Chapter 5. Polymer additives used to enhance material properties for medical device applications. In: Plastics in medical devices 2010, pp.55–72. Elsevier.10.1016/B978-0-8155-2027-6.10005-4 ↗
11. 10.1002/app.3798010.1002/app.37980 ↗
12. 10.1093/rpd/ncp05310.1093/rpd/ncp053 ↗
13. 10.1016/j.apradiso.2011.12.04010.1016/j.apradiso.2011.12.040 ↗
14. 10.1118/1.242640410.1118/1.2426404 ↗
15. 10.1118/1.326083910.1118/1.3260839 ↗
16. 10.1093/rpd/ncn24410.1093/rpd/ncn244 ↗
17. Morton M. Chapter 13. Silicone rubber. In: Rubber technology. Dordrecht: Springer Science, 1999, pp.375-409.10.1007/978-94-017-2925-3_13 ↗
18. International Electrotechnical Commission, IEC 61267: 2005. Medical diagnostic X-ray equipment – radiation conditions for use in the determination of characteristics.
19. Hubbell JH, et al. Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients 1 keV to 20 MeV for elements z = 1 to 92 and 6048 additional substances of dosimetric interest . Technical Report. Report no. NISTIR-5632, May 1995.10.6028/NIST.IR.5632 ↗
20. ISO 5402-1:2011 Leather, Determination of flex resistance, Part 1: Flexometer method.
21. ASTM D 1388-08 · 2008
22. http://www.mathworks.com/help/stats/nonlinearmodel.fit.html.
23. Berger M et al. (2010) XCOM: photon cross sections database, http://www.nist.gov/pml/data/xcom/index.cfm.
24. Institute of Physics and Engineering in Medicine. Medical guidance notes . 2002. Paragraph 3.119.
25. 10.1016/j.compositesb.2008.01.00210.1016/j.compositesb.2008.01.002 ↗