Optimal Material Selection for Polymer–Polymer Prosthetic Implants by Tribological Criteria
Source abstract
Abstract
A polymer–polymer tribological pair made of antifriction ultrahigh molecular weight polyethylene (UHMWPE) and high-strength polyetheretherketone (PEEK) composites was proposed and tested in various operating conditions (lubrication medium and dry friction at a deficit of synovial fluid in the joint). The selection of fillers for UHMWPE and PEEK was substantiated in steps proceeding from the data of systematic mechanical and tribological tests. The optimal composition of the composites, suggesting the possibility of manufacturing customized joint prosthetic implants using additive manufacturing technologies, is determined. It was shown that the PEEK (pin)-on-UHMWPE (disk) tribological pair is well compatible, characterized by a low coefficient of friction (f = 0.02), and zero wear found by optical microscopy observations. The friction of non-filled UHMWPE on PEEK reinforced with two types of carbon fibers (milled carbon fibers, 30 wt % and CNT, 2.5 wt %) is checked. It is shown that carbon nanotubes are efficient fillers for PEEK in the UHMWPE–PEEK tribological pair under dry sliding friction at a deficiency of synovial fluid.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Tribology and Wear Analysis · Total Knee Arthroplasty Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (19)
Show source-provided references
1. Tudor, A., Laurian, T., and Popescu, V.M., The effect of clearance and wear on the contact pressure of metal on polyethylene hip prostheses, Tribol. Int., 2013, vol. 63, pp. 158–168. https://doi.org/10.1016/j.triboint.2012.11.00210.1016/j.triboint.2012.11.002 ↗
2. Kurtz, S., High pressure crystallized UHMWPEs, in UHMWPE Biomaterials Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement and Medical Devices, 3rd ed., Kurtz, S.M., Ed., Amsterdam: Elsevier, 2016, ch. 24, pp. 434–448.
3. Friedrich, K., Polymer composites for tribological applications, Adv. Ind. Eng. Polym. Res., 2018, vol. 1, pp. 3–39. https://doi.org/10.1016/j.aiepr.2018.05.00110.1016/j.aiepr.2018.05.001 ↗
4. Merola, M. and Affatato, S., Materials for hip prostheses: a review of wear and loading considerations, Materials, 2019, vol. 12, p. 495. https://doi.org/10.3390/ma1203049510.3390/ma12030495 ↗
5. Buford, A. and Goswami, T., Review of wear mechanisms in hip implants: Paper I—General, Mater. Des., 2004, vol. 25, pp. 385–393. https://doi.org/10.1016/j.matdes.2003.11.01010.1016/j.matdes.2003.11.010 ↗
6. Ramakrishna, S., et al., Biomedical applications of polymer-composite materials: a review, Compos. Sci. Technol., 2001, vol. 61, pp. 1189–1224.10.1016/S0266-3538(00)00241-4 ↗
7. Hall, R. M. and Unsworth, A., Friction in hip prostheses, Biomaterials, 1997, vol. 18, no. 15, pp. 1017–1026.10.1016/S0142-9612(97)00034-3 ↗
8. Brandt, J. and Hein, W., Polymer materials in joint surgery, in Deformation and Fracture Behaviour of Polymers, Grellmann, W. and Seidler, S., Eds., Berlin: Springer-Verlag, 2001. https://doi.org/10.1007/978-3-662-04556-5_3010.1007/978-3-662-04556-5_30 ↗
9. Spiegelberg, S., Kozak, A., and Braithwaite, G., Characterization of physical, chemical, and mechanical properties of UHMWPE, in UHMWPE Biomaterials Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement and Medical Devices, 3rd ed., Kurtz, S.M., Ed., Amsterdam: Elsevier, 2016, ch. 29, pp. 531–552. ISBN 9780323354011. https://doi.org/10.1016/B978-0-323-35401-1.00029-610.1016/B978-0-323-35401-1.00029-6 ↗
10. Fang, L., Leng, Y., and Gao, P. Processing and mechanical properties of HA/UHMWPE nanocomposites, Biomaterials, 2006, vol. 27, pp. 3701–3707.10.1016/j.biomaterials.2006.02.023 ↗
11. Shil’ko, S.V., Starzhinskii, V.E., Petrokovets, E.M., and Chernous, D.A., Two-level calculation method for tribojoints made of disperse-reinforced composites: Part 1, J. Frict. Wear, 2013, vol. 34, no. 1, pp. 65–69.10.3103/S1068366613010133 ↗
12. Essner, A., Sutton, K., and Wang, A., Hip simulator wear comparison of metal-on-metal, ceramic-on-ceramic and crosslinked UHMWPE bearings, Wear, 2005, vol. 259, pp. 992–995. https://doi.org/10.1016/j.wear.2005.02.10410.1016/j.wear.2005.02.104 ↗
13. Scholes, S.C. and Unsworth, A., Wear studies on the likely performance of CFR-PEEK/CoCrMo for use as artificial joint bearing materials, J. Mater. Sci.: Mater. Med., 2009, vol. 20, pp. 163–170. https://doi.org/10.1007/s10856-008-3558-310.1007/s10856-008-3558-3 ↗
14. Cowie, R.M., Briscoe, A., Fisher, J., and Jennings, L.M., Wear and friction of UHMWPE-on-PEEK OPTIMA, J. Mech. Behav. Biomed. Mater., 2019, vol. 89, pp. 65–71. https://doi.org/10.1016/j.jmbbm.2018.09.02110.1016/j.jmbbm.2018.09.021 ↗
15. Wang, A., Lin, R., Stark, C., and Dumbleton, J., Suitability and limitations of carbon fiber reinforced PEEK composites as bearing surfaces for total joint replacements, Wear, 1999, vol. 225, pp. 724–727.10.1016/S0043-1648(99)00026-5 ↗
16. Brockett, C.L., Carbone, S., Fisher, J., and Jennings, L.M., PEEK and CFR-PEEK as alternative bearing materials to UHMWPE in a fixed bearing total knee replacement: an experimental wear study, Wear, 2017, vols. 374–375, pp. 86–91. https://doi.org/10.1016/j.Wear.2016.12.01010.1016/j.Wear.2016.12.010 ↗
17. East, R.H., Briscoe, A., and Unsworth, A., Wear of PEEK-OPTIMA® and PEEK-OPTIMA®-wear performance articulating against highly cross-linked polyethylene, Proc. Inst. Mech. Eng., Part H, 2015, vol. 229, pp. 187–193. https://doi.org/10.1177/095441191557635310.1177/0954411915576353 ↗
18. Pinchuk, L.S., Nikolaev, V.L., Tsvetkova, E.A., and Goldade, V.A., Tribology and Biophysics of Artificial Joints, Amsterdam: Elsevier, 2005.
19. Panin, S.V., Buslovich, D.G., Dontsov, Y.V., Kornienko, L.A., Alexenko, V.O., Bochkareva, S.A., and Shilko, S.V., Two-component feedstock based on ultra-high molecular weight polyethylene for additive manufacturing of medical products, Adv. Ind. Eng. Polym. Res., 2021, vol. 4, pp. 235–250. https://doi.org/10.1016/j.aiepr.2021.05.00310.1016/j.aiepr.2021.05.003 ↗