journal article·2024-01

Forced convective heat transfer in vegetation by measuring liquid water evaporation

Kunhyuk Sung, Eric Mueller, Anthony Hamins

Journal of Fire Sciences· Volume 42· Issue 1
Publisher page

Abstract

A series of experiments was conducted to develop a method to estimate the convective heat transfer in vegetative fuels with a complex geometry through the measurement of liquid water evaporation. A water mist was sprayed onto vegetative test specimens, coating their entire surface with a thin water layer. The water evaporation rate was measured using a load cell in a wind tunnel under controlled conditions while an infrared camera tracked the surface temperatures. Convective heat transfer was calculated by the difference between the free stream and surface temperatures and the measured evaporation rate, considering the energy balance of the water layer at steady state. The method was verified through evaporation tests using a wood cylinder array. Experiments were conducted using nominally 30 cm branches of a typical conifer, Norway Spruce ( Picea abies), yielding the conventional form of the Nusselt number–Reynolds number power–law relationship: Nu=C Re n Pr 1/3 with coefficients C = 0.69 ± 0.25 and n = 0.34 ± 0.06.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Plant Water Relations and Carbon Dynamics · Heat Transfer Mechanisms · Fluid Dynamics and Turbulent Flows

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

National Institute of Standards and Technology (NIST), Gaithersburg, MD, USA

References (26)

Show source-provided references
1. Fons WL. · J Agri Res · 1946 · 72 · 93
2. 10.1073/pnas.150449811210.1073/pnas.1504498112 ↗
3. 10.1080/00102202.2021.201923210.1080/00102202.2021.2019232 ↗
4. 10.1007/s10694-010-0160-210.1007/s10694-010-0160-2 ↗
5. 10.1007/978-3-319-60282-0_610.1007/978-3-319-60282-0_6 ↗
6. 10.1016/j.combustflame.2017.09.03810.1016/j.combustflame.2017.09.038 ↗
7. 10.1080/0010220860892384410.1080/00102208608923844 ↗
8. 10.1002/j.1537-2197.1964.tb06666.x10.1002/j.1537-2197.1964.tb06666.x ↗
9. 10.1002/j.1537-2197.1965.tb06758.x10.1002/j.1537-2197.1965.tb06758.x ↗
10. Mendes-Lopes J
11. 10.1016/j.ijheatmasstransfer.2022.12305710.1016/j.ijheatmasstransfer.2022.123057 ↗
12. 10.1111/j.1469-8137.2006.01661.x10.1111/j.1469-8137.2006.01661.x ↗
13. 10.1016/j.ijthermalsci.2012.02.01010.1016/j.ijthermalsci.2012.02.010 ↗
14. 10.1016/0894-1777(94)00071-F10.1016/0894-1777(94)00071-F ↗
15. 10.1016/0002-1571(73)90017-410.1016/0002-1571(73)90017-4 ↗
16. 10.2134/agronj1966.00021962005800060014x10.2134/agronj1966.00021962005800060014x ↗
17. 10.1016/j.compag.2008.05.01710.1016/j.compag.2008.05.017 ↗
18. 10.1016/j.combustflame.2018.05.02810.1016/j.combustflame.2018.05.028 ↗
19. 10.1016/j.scienta.2012.01.02210.1016/j.scienta.2012.01.022 ↗
20. 10.1016/S0034-4257(96)00123-X10.1016/S0034-4257(96)00123-X ↗
21. 10.1006/cgip.1994.104210.1006/cgip.1994.1042 ↗
22. 10.1002/jbmr.192710.1002/jbmr.1927 ↗
23. 10.1109/TPAMI.2003.117715610.1109/TPAMI.2003.1177156 ↗
24. ASTM D2395-17:2022 · Test Method B—Volume by Water Immersion
25. Incropera FP · 2007
26. Heckert NA · 2002