An analysis of the WTC fires using CIB correlations and simple modeling
Source abstract
Abstract
CIB correlations for compartment burning rates and average gas temperatures are examined for accuracy, utility, and generality. The results are applied to modeling the fire on 9/11 in WTC 1. Specific information is used from the NIST investigation. It is demonstrated that simple heat transfer modeling can predict the truss steel rod temperatures for the E119 tests of WTC done by NIST. The CIB temperature correlation and steel truss modeling are used to predict burning conditions for the WTC 1 96th floor fire and compared to the NIST results. Here a consideration of fuel loads from 20 to 40 kg/m 2 was considered compared to just 20 used by NIST. The results suggest that the fully insulated truss bar temperatures would achieve higher values for higher fuel loads. A critical steel truss temperature of 650°C could support failure of the trusses as a theory for the collapse of the towers.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fire dynamics and safety research · Fire effects on concrete materials · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Emeritus, Department of Fire Protection Engineering, University of Maryland, College Park, MD, USA
References (29)
Show source-provided references
1. 10.1007/s10694-012-0288-310.1007/s10694-012-0288-3 ↗
2. Gann RG · 2005
3. National Institute of Standards and Technology Investigation of the 2001 World Trade Center Fires* The Forum: J of Fire Sci 2014; 32(3): 281–291.10.1177/0734904114528457 ↗
4. Dinenno P · 1995
5. Lie TT · 1992
6. Thomas PH, Heselden AJM. Fire research station. FR Note 923, CIB Report 20, August 1972, p. 85, https://firedoc.nist.gov/article/AVoZ0Kbb5tyd0g1lPvqV
7. Law M · Struct Eng · 1983 · 61 · 25
8. Hunt SP, Cutonilli J. Evaluation of enclosure temperature, empirical models. Society of Fire Protection Engineers, Technical Report, 9 November 2010, https://cdn.ymaws.com/sites/sfpe.site-ym.com/resource/resmgr/Docs/Method_Evaluation.pdf
9. SFPE. Standard S.01—Calculating fire exposures to structures, 2010.
10. 10.1007/BF0247958310.1007/BF02479583 ↗
11. Quintiere JG · 2009
12. 10.1016/j.firesaf.2012.06.00310.1016/j.firesaf.2012.06.003 ↗
13. 10.1016/j.proeng.2013.08.04010.1016/j.proeng.2013.08.040 ↗
14. Utiskul Y · 2008
15. Gross JL, Hervey F, Izydorek M, et al. Fire resistance tests of the floor truss systems. federal building and fire safety investigation of the world trade center disaster (NIST NCSTAR 1-6B), 2005, https://www.nist.gov/publications/fire-resistance-tests-floor-truss-systems-federal-building-and-fire-safety-010.6028/NIST.NCSTAR.1-6b ↗
16. Harmathy TZ. DBR Paper No. 1080, Division of Building Research, National Research Council Canada, (DBR/NRC), 1983, https://www.jstor.org/stable/43028681?seq=1
17. UL Proj. 87NK6590, June 23, 1988, to Isolatek International Corp., Thermal Properties of Type D-C/F Sprayed Fiber.
18. Prasad K, Baum H. Fire structure interface and thermal response of world trade center towers. Federal building and fire safety investigation of the world trade center disaster (NIST NCSTAR 1-5G), 2005, https://www.nist.gov/publications/fire-structure-interface-and-thermal-response-world-trade-center-towers-federal10.6028/NIST.NCSTAR.1-5g ↗
19. ANSI/ASTM E119. Standard methods of fire tests of building construction and materials.
20. Gann RG · Federal Building and Fire Safety Investigation of the World Trade Center Disaster (NIST NCSTAR 1-5) · 2005 · 1
21. Caro TC · 1996
22. Quintiere JG · 2005
23. Kirkpatrick SW, Bocchieri R, Sadek F, et al. Analysis of aircraft impacts into the world trade center towers, federal building and fire safety investigation of the world trade center disaster (NIST NCSTAR 1-2b), 2005, https://www.govinfo.gov/content/pkg/GOVPUB-C13-8a912a078ac4b241d945e3cb8995ef55/pdf/GOVPUB-C13-8a912a078ac4b241d945e3cb8995ef55.pdf
24. Pitts WM, Butler KM, Junker V. Visual evidence, damage estimates, and timeline analysis (Chapters 9-Appendix C). Federal Building and Fire Safety Investigation of the World Trade Center Disaster (NIST NCSTAR 1-5A), 2005, https://www.nist.gov/publications/visual-evidence-damage-estimates-and-timeline-analysis-chapters-9-appendix-c-federal10.6028/NIST.NCSTAR.1-5av2 ↗
25. McGrattan KB, Bouldin C, Forney GP. Computer simulations of the fires in the world trade center towers, Federal Building and Fire Safety Investigation of the World Trade Center Disaster (NCSTAR 1-5F), 2005, https://www.nist.gov/publications/computer-simulation-fires-world-trade-center-towers-federal-building-and-fire-safety-010.6028/NIST.NCSTAR.1-5f ↗
26. Interim Report on Subsystem Structural Analysis of the WTC Towers Appendix K. Federal building and fire safety investigation of the world trade center disaster, (NIST NCSTAR)2005, pp. K54–K61, https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication1000-5v1.pdf
27. 10.1016/S0379-7112(02)00034-610.1016/S0379-7112(02)00034-6 ↗
28. Torero J. L.
29. Quintiere JG · 1009