Toxic Gases Evolution from Commercial Building Materials under Fire Atmosphere in a Semi-Full-Scale Room
Source abstract
Abstract
Commercial building materials of board type assembled into a box shape, were each independently combusted in a semi-full-scale room along with methanol, which was supplied at a constant rate, under the conditions of forced air supply by blower. Primary toxic gases were CO and acrolein from wood-based materials, and CO and HCN from urethanes. From phenol foams, evolution of CO and other toxic gases was very small. A comparison was made between the evolution of toxic gases from materials assembled in a box shape and also in a crib shape. It was found that the total toxicity, E(C 1 /C fi ), and concentrations of the above toxic gases were much higher for the box shape than for the crib shape.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fire dynamics and safety research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Fire Research Institute Fire Defence Agency Home Affairs Ministry of Japanese Government 14-1, Nakahara 3 Chome Mitaka, Tokyo 181, Japan
References (6)
Show source-provided references
1. Morikawa, T., et al. Report of Fire Research Institute of Japan, No. 60, pp. 95-105 (1985).
2. Pharmaceutical Society of Japan, Standard Methods of Analysis of Hygienic Chemists, Kanehara Publishing Co., p. 1006 (1973) [in Japanese].
3. Japanese Science and Technology Agency, Report on a Cooperative Study between US, Canada and Japan on Toxicity and Safety Evaluation of Burning Building and Other Materials, p. 52 (1987) [in Japanese].
4. ISO Draft Technical Report DP 9122, p. 35 (1985).
5. 10.1126/science.20814310.1126/science.208143 ↗
6. Sumi, K. · Journal of Combustion Toxicology · 1975 · 2 · 8