journal article·1985-03

Model Tests of Aircraft Interior Panel Flammability

Allan Abramowitz, Thor I. Eklund

Journal of Fire Sciences· Volume 3· Issue 2
Publisher page

Abstract

Prototype aircraft interior panels were installed as ceilings in a quarter-scale enclosure model lined with a non-flammable insulating material. Flashover con ditions were generated by a 52-kilowatt propane burner. The heat requirements for flashover, with an inert ceiling, agreed with those predicted by an NBS cor relation for full-scale room fires. The flammability of the prototype panels was experimentally found to be related to their ignition temperatures. In these tests, Nomex™ honeycomb panels with epoxy impregnated facesheets as well as those with phenolic impregnated Kevlar™, sustained ignition. The panels faced with phenolic impregnated fiberglass or graphite did not burn.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Flame retardant materials and properties · Combustion and Detonation Processes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

FAA Technical Center Atlantic City Airport, N.J.

References (6)

Show source-provided references
1. Sarkos, C.P. · 1982
2. Sarkos, C.P. · 1985
3. 10.1007/BF0247958310.1007/BF02479583 ↗
4. 10.6028/NBS.IR.82-259810.6028/NBS.IR.82-2598 ↗
5. Eklund, T.I. · 1984
6. Quintiere, J.G., et al · 1985