journal article·2009-12-01

ADDITION OF THE FORCE MEASUREMENT CAPABILITY TO A COMMERCIALLY AVAILABLE EXTENSIONAL RHEOMETER (CABER)

Christopher O. Klein, Ingo F. C. Naue, Jint Nijman, Manfred Wilhelm

Soft Materials· Volume 7· Issue 4
Publisher page

Abstract

The Capillary Breakup Extensional Rheometer (CaBER) is the only commercially available elongational rheometer. The CaBER can measure the diameter of a low viscous sample under stretching as a function of time. The analysis of this setup is consequently limited to the time dependent diameter of the capillaries D (t). Some samples do not develop a proper capillary flow, because of, for example, a lack of a substantial surface tension or a cylindrical fluid filament. As a consequence the interpretation of the results based on D (t) is problematic. On the other hand there is a huge fundamental industrial interest in measuring properties like strand formation, stickiness, spreadability, and so on. These properties are related to the extensional properties, specifically the elongational viscosity of a sample. Therefore, additional information beside D (t) is needed. In this publication a newly developed extension of the CaBER is presented and first applications are shown. The viscous sample is placed between two plates and afterward extended quickly by moving the upper plate. The normal force acting on the lower plate is measured as a function of time. To measure these small forces (<0.05 mN) with very short time resolution (e.g., dwell‐times down to 0.2 ms) a piezo transducer is used in combination with modern data oversampling techniques to further increase the sensitivity of the transducer. In this article the CaBER modifications are presented in detail to simultaneously measure the diameter and the force down to 5*10−5 N, with 10−3 s time resolution.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Rheology and Fluid Dynamics Studies · Polysaccharides Composition and Applications · Polymer crystallization and properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

a Institut für Technische Chemie und Polymerchemie , Universität Karlsruhe , Karlsruhe, Germany

b Material Characterization , Thermo Scientific , Karlsruhe, Germany

References (21)

Show source-provided references
1. Tripathi P. · J. Rheol. · 2000 · 44 · 65310.1122/1.551105 ↗
2. 10.1122/1.55005810.1122/1.550058 ↗
3. Sattler R. · Phys. Rev. Lett. · 2008 · 10010.1103/PhysRevLett.100.164502 ↗
4. Matta J. E. · J. Non‐Newtonian Fluid Mech. · 1990 · 35 · 21510.1016/0377-0257(90)85050-9 ↗
5. Bazilevskii A. V. · Proceedings of the 3rd European Rheology Conference · 1990
6. Bazilevskii A. V. · Polym. Sci., Ser. A · 1997 · 39 · 316
7. Anna S. L. · J. Rheol. · 2001 · 45 · 8310.1122/1.1332388 ↗
8. 10.1007/s00397000007210.1007/s003970000072 ↗
9. Wagner C. · Europhys. Lett. · 2003 · 64 · 82310.1209/epl/i2003-00632-4 ↗
10. 10.1122/1.133238910.1122/1.1332389 ↗
11. 10.1063/1.86904410.1063/1.869044 ↗
12. Kolte M. I. · J. Rheol. · 1999 · 43 · 60910.1122/1.550995 ↗
13. Stelter M. · J. Rheol. · 2000 · 44 · 59510.1122/1.551102 ↗
14. Szabo P. · Rheol. Acta · 1997 · 36 · 277
15. 10.1002/352760231310.1002/3527602313 ↗
16. Dusschoten D. V. · Rheol. Acta · 2001 · 40 · 39510.1007/s003970000158 ↗
17. Neidhöfer T. · J. Rheol. · 2003 · 47 · 135110.1122/1.1608954 ↗
18. Klein C. · Appl. Rheology · 2007 · 17 · 45210110.1515/arh-2007-0015 ↗
19. Colby R. H. · 1990 · 23
20. Endoh M. K. · Macromolecules · 2002 · 35 · 769210.1021/ma0203389 ↗
21. Hilliou L. · Ind. Eng. Chem. Res. · 2002 · 41 · 624610.1021/ie0110078 ↗