Abstract

Current commercial tensile testing systems use spring-loaded or other compression-based grips to clamp materials in place posing a problem for very soft or delicate materials that cannot withstand this mechanical clamping force. In order to perform uniaxial tensile tests on soft tissues or materials, we have created a novel vacuum-assisted anchor (VAA). Fibrin gels were subjected to uniaxial extension, and the testing data was used to determine material mechanical properties. Utilizing the VAA, we achieved successful tensile breaks of soft fibrin gels while finding statistically significant differences between the mechanical properties of gels fabricated at two different fibrinogen concentrations.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Blood properties and coagulation · Electrospun Nanofibers in Biomedical Applications · Elasticity and Material Modeling

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. 10.1152/ajpheart.00479.200410.1152/ajpheart.00479.2004 ↗
2. 10.1016/j.biomaterials.2010.09.01910.1016/j.biomaterials.2010.09.019 ↗
3. 10.1073/pnas.071121710510.1073/pnas.0711217105 ↗
4. 10.1016/j.biomaterials.2007.04.01210.1016/j.biomaterials.2007.04.012 ↗
5. 10.1089/ten.a.2007.014810.1089/ten.a.2007.0148 ↗
6. 10.1089/10763270332249561910.1089/107632703322495619 ↗
7. 10.1002/jbm.a.3104110.1002/jbm.a.31041 ↗
8. 10.1007/s12195-013-0289-410.1007/s12195-013-0289-4 ↗
9. 10.1007/s10439-010-0192-210.1007/s10439-010-0192-2 ↗
10. Lake S. P. · Ann. Biomed. Eng · 1891 · 39
11. 10.1016/j.biomaterials.2003.10.07310.1016/j.biomaterials.2003.10.073 ↗
12. 10.1016/j.actbio.2006.08.00610.1016/j.actbio.2006.08.006 ↗
13. 10.1021/bm060223310.1021/bm0602233 ↗
15. 10.1016/S0006-3495(81)84817-510.1016/S0006-3495(81)84817-5 ↗
16. 10.1098/rsta.1951.000410.1098/rsta.1951.0004 ↗
17. Christensen R. M. · Acta Mech · 2008 · 19610.1007/s00707-007-0478-0 ↗
18. 10.1039/C2RA22859A10.1039/C2RA22859A ↗
19. 10.1002/jbm.121710.1002/jbm.1217 ↗
20. Cloyd J. M. · Eur. Spine J · 1892 · 1610.1007/s00586-007-0443-6 ↗
21. Mauck R. L. · J. Biomech. Eng · 122 · 25210.1115/1.429656 ↗
22. 10.1002/1097-4636(200101)54:1<115::AID-JBM14>3.0.CO;2-Q10.1002/1097-4636(200101)54:1<115::AID-JBM14>3.0.CO;2-Q ↗
23. 10.1016/S0006-3495(99)77113-410.1016/S0006-3495(99)77113-4 ↗