Abstract
Abstract Motion monitoring systems are often designed and researched to detect the movement of human lower limbs, and play an important role in the field of exoskeleton control. However, current wearable devices can still be improved to be more convenient or accurate in motion recognition. In this work, a comfortable smart wearable gait monitoring system was designed and tested. Inertial measurement units (IMUs) and flexible membrane compression sensors were implemented, integrated to a comfortable sport pant and insoles of both feet, respectively. Data acquisition module was designed, while software with user interface for data collection and storage was realized based on LABVIEW. Experiments were conducted to evaluate the recognition performance of the smart wearable gait monitoring system among nine common actions. Results show that the combined data set of IMUs and compression sensor provided by the system can highly improve classification performance. Based on the self-designed sensing network and the K-nearest neighbor machine learning algorithm, the recognition rate of nine motion patterns can reach as high as 99.96%, showing that the multi-channel wearable gait monitoring system is more effective for motion detection and prediction compared to that with single-type sensors.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Muscle activation and electromyography studies · Non-Invasive Vital Sign Monitoring · Balance, Gait, and Falls Prevention
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. Non-rigid alignment pipeline applied to human gait signals acquired with optical motion capture systems and inertial sensors10.1016/j.jbiomech.2019.109429 ↗
2. Inertial measurement unit compared to an optical motion capturing system in post-stroke individuals with foot-drop syndrome10.1016/j.rehab.2019.03.007 ↗
3. A wireless human motion monitoring system for smart rehabilitation10.1115/1.4033949 ↗
4. Wearable gait measurement system with an instrumented cane for exoskeleton control10.3390/s140101705 ↗
5. Parameter identification and adaptive compliant control of rehabilitation exoskeleton based on multiple sensors10.1016/j.measurement.2020.107765 ↗
6. Wearable human motion posture capture and medical health monitoring based on wireless sensor networks10.1016/j.measurement.2020.108252 ↗
7. Data-driven human model estimation for realtime motion capture10.1016/j.jvlc.2018.05.001 ↗
8. Accurate recognition of lower limb ambulation mode based on surface electromyography and motion data using machine learning10.1016/j.cmpb.2020.105486 ↗
9. Monitoring of human body running training with wireless sensor based wearable devices10.1016/j.comcom.2020.04.015 ↗
10. Recent advances of wearable and flexible piezoresistivity pressure sensor devices and its future prospects10.1016/j.jmat.2020.01.009 ↗
11. Highly sensitive and stable printed pressure sensor with microstructured grid arrays10.1088/1361-665X/ab3af6 ↗
12. Flexible wide-range capacitive pressure sensor using micropore PE tape as template10.1088/1361-665X/ab4ac6 ↗
13. A comparative analysis of capacitive-based flexible PDMS pressure sensors10.1016/j.sna.2018.11.014 ↗
14. Gait-based identification for elderly users in wearable healthcare systems10.1016/j.inffus.2019.06.023 ↗
15. Wearable sensors to monitor, enable feedback, and measure outcomes of activity and practice10.1007/s11910-018-0896-5 ↗
16. Free viewpoint action recognition using motion history volumes10.1016/j.cviu.2006.07.013 ↗
17. Real-time human action recognition based on depth motion maps10.1007/s11554-013-0370-1 ↗
18. Pattern recognition of electromyography signals based on novel time domain features for amputees’ limb motion classification10.1016/j.compeleceng.2017.04.003 ↗
19. A CNN-SVM combined model for pattern recognition of knee motion using mechanomyography signals10.1016/j.jelekin.2018.07.005 ↗
20. Reducing the metabolic rate of walking and running with a versatile, portable exosuit10.1126/science.aav7536 ↗
21. Autonomous and portable soft exosuit for hip extension assistance with online walking and running detection algorithm10.1109/ICRA.2018.8460474 ↗
22. Validation of inter-subject training for hidden Markov models applied to gait phase detection in children with cerebral palsy10.3390/s150924514 ↗
23. Effective inertial sensor quantity and locations on a body for deep learning-based worker’s motion recognition10.1016/j.autcon.2020.103126 ↗
24. The use of wearable devices for walking and running gait analysis outside of the lab: a systematic review10.1016/j.gaitpost.2018.04.047 ↗
25. Flexible pressure sensors for smart protective clothing against impact loading10.1088/0964-1726/23/1/015001 ↗
26. A neural network-based gait phase classification method using sensors equipped on lower limb exoskeleton robots10.3390/s151127738 ↗
27. Real-time gait event detection using wearable sensors10.1016/j.gaitpost.2009.07.128 ↗
28. Signal extraction and monitoring of motion loads based on wearable online device10.1016/j.comcom.2020.02.072 ↗
29. Industrial applications of the Kalman filter: a review10.1109/TIE.2012.2236994 ↗
30. Kalman filtering with state constraints: a survey of linear and nonlinear algorithms10.1049/iet-cta.2009.0032 ↗
31. Vision based weed recognition using LabVIEW environment for agricultural applications10.1016/j.matpr.2019.05.389 ↗
32. The design of LDF data acquisition system based on LabVIEW10.1016/j.proenv.2011.09.190 ↗
33. Morris · 2016 · 34710.1016/C2013-0-15387-1 ↗
34. Decision tree SVM: an extension of linear SVM for non-linear classification10.1016/j.neucom.2019.10.051 ↗
35. Scikit-learn: machine learning in Python10.5555/1953048.2078195 ↗
36. A survey on approaches of motion mode recognition using sensors10.1109/TITS.2016.2617200 ↗