journal article·2011-05

Development of 100-W High-Efficiency MPPT Power Conditioner and Evaluation of TEG System with Battery Load

Hiroshi Nagayoshi, Tatsuya Nakabayashi, Hiroshi Maiwa, Takenobu Kajikawa

Journal of Electronic Materials· Volume 40· Issue 5
Publisher page

Abstract

This paper describes a practical high-efficiency thermoelectric (TE) power conditioner with maximum power point tracking (MPPT) control for thermoelectric generators and the operation results for a battery load system. This power conditioner comprises a high-frequency step-up/step-down switching converter and a microcontroller; a synchronized switching circuit is introduced to achieve high conversion efficiency. Furthermore, it is equipped with a battery charge control program and has a maximum conversion efficiency of 96.7%. An impedance matching method developed for MPPT control showed excellent response against a change in the TEG output, making it suitable for solar TEGs as well as general applications.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Photovoltaic System Optimization Techniques · Advanced Thermoelectric Materials and Devices · solar cell performance optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (19)

Show source-provided references
1. K.T. Zorbas, E. Hatzikraniotis, and K.M. Paraskevopoulos, Proceedings of the 5th European Conference on Thermoelectronics (2007), p. 10.
2. J. Fairbanks, Proceedings of the 6th Conference of European Conference on Thermoelectrics, PL-00-1 (2008).
3. T. Ota, C. Tokunaga, and K. Fujita, Proceedings of the 23rd International Conference of Thermoelectronics (2005), p. 320.
4. J. LaGrandeur, D. Crane, S. Hung, B. Mazar, and A. Eder, Proceedings of the 25th International Conference on Thermoelectronics, (2006), p. 343.
5. T. Ryu, OKI Technical Review 214,76,1,40-43(2009).10.1260/nvww.40.1.u3612h186x677774 ↗
6. D.T. Crane, J.W. LaGrandeur, F. Harris, and L.E. Bell, JMES38, 7, 1375 (2009).
7. K.T. Chau, Y.S. Wong, and C.C. Chan, Energy Convers. Manag. 40, 1021 (1999).10.1016/S0196-8904(99)00021-7 ↗
8. K.T. Chau and Y.S. Wong, Energy Convers. Manag. 43, 1953 (2002).10.1016/S0196-8904(01)00148-0 ↗
9. H. Nagayoshi and T. Kajikawa, Proceedings of the 3rd Conference of European Conference on Thermoelectrics (2005), p. 76.
10. H. Nagayoshi, K. Tokumitsu, and T. Kajikawa, Proceedings of the 5th European Conference on Thermoelectronics (2007), p. 80.
11. H. Nagayoshi and T. Kajikawa, Proceedings of the 25th International Conference on Thermoelectronics (2006), p. 210.
12. X. Zhang, K.T. Chau, and C.C. Chan, J. Asian Electric Vehicles 6, 1120 (2008).
13. X. Zhang, W. Li, and J. Li, Proceedings of the 8th International Conference in Power System Control, Operation and Management (2009), p. 133.
14. R.Y. Kim, J.S. Lai, and B. York, IEEE Trans. Ind. Electron. 56, 3709 (2009).10.1109/TIE.2009.2025717 ↗
15. M. Azab, Proceedings of World Academic of Science, Engineering and Technology, vol. 34 (2070), p. 2070.
16. A. Yafaoui, B. Wu, and R.R. Cheung, Proceedings of the 2nd Canadian Solar Buildings Conference (2007), p. 1.
17. N. Femia, G. Petrone, and M. Vitelli, IEEE Trans. Ind. Electron. 50, 749 (2003).10.1109/TIE.2003.814762 ↗
18. D.P. Hohm and M.E. Ropp, Prog. Photovolt: Res. Appl. 11, 47 (2003).10.1002/pip.459 ↗
19. J. Eakburanawat and I. Boonyaroonate, Appl. Energ. 83, 687 (2006).10.1016/j.apenergy.2005.06.004 ↗