journal article·2025-10Open access

A New Generation of MCT-Based p-on-n Technology for Focal-Plane Arrays Ranging from SWIR to VLWIR

C. Lobre, T. Le Goff, T. Journot, N. Baier, E. Serres, L. Rubaldo, F. Rochette, F. Marmonier, C. Grezes, C. Cassillo, O. Gravrand

Journal of Electronic Materials· Volume 54· Issue 10

Abstract

Abstract The recent advancements in antimonide-based technologies for cooled infrared imaging systems, coupled with the industry trend toward SWaP-C (size, weight, and power-cost), have led to a heightened emphasis on the manufacturing efficiency and performance stability of infrared focal-plane arrays (IRFPAs). This article presents a new generation of p-on-n technology for IRFPAs based on mercury cadmium telluride (MCT), developed by the joint laboratory of Leti and Lynred. This development is specifically designed to address the growing need to enhance the electro-optical performance of the devices, particularly in terms of image quality and low-frequency stability. The new process outlined herein is founded upon three key features: the utilization of high-quality materials, the optimization of the process through the application of fundamental research, and the implementation of a dedicated diode architecture. The versatility of MCT enables this technology to cover a broad spectral range, from short-wave infrared (SWIR) to very long-wave infrared (VLWIR). This paper presents the successful fabrication of IRFPAs that span this entire spectral range and the results of an electro-optical characterization of the aforementioned prototypes, with a particular focus on low-frequency performance metrics. The results demonstrate that this new generation of p-on-n devices exhibits enhanced operability and uniformity across the focal-plane array, which is characteristic of this new p-on-n generation. These improvements result in notable enhancements in residual fixed-pattern noise (RFPN) for high-temperature applications in the mid-wave band and reduced persistence for astronomical applications.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Semiconductor Detectors and Materials · Infrared Target Detection Methodologies · Adaptive optics and wavefront sensing

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (19)

Show source-provided references
1. O. Gravrand, A. Kerlain, D. Sam-Giao, M. Soria, and J. Rothman, The Tobin coefficient: a relevant photodetector performance metric for IR imaging. J. Electron. Mater. 53(10), 5874–5884 (2024). https://doi.org/10.1007/s11664-024-11302-7.10.1007/s11664-024-11302-7 ↗
2. L. Zheng and M. Tidrow, Analyses of infrared focal plane array figure of merit and its impact on sensor system trades. Infrared Phys. Technol. 52(6), 408 (2009). https://doi.org/10.1016/j.infrared.2009.08.001.10.1016/j.infrared.2009.08.001 ↗
3. R.L. Strong, M.A. Kinch, and J.M. Armstrong, Performance of 12-μm- to 15-μm-Pitch MWIR and LWIR HgCdTe FPAs at elevated temperatures. J. Electron. Mater. 42(11), 3103 (2013). https://doi.org/10.1007/s11664-013-2658-0.10.1007/s11664-013-2658-0 ↗
4. O. Gravrand, G. Destefanis, S. Bisotto, N. Baier, J. Rothman, L. Mollard, D. Brellier, L. Rubaldo, A. Kerlain, V. Destefanis, and M. Vuillermet, Issues in HgCdTe research and expected progress in infrared detector fabrication. J. Electron. Mater. 42(11), 3349 (2013). https://doi.org/10.1007/s11664-013-2803-9.10.1007/s11664-013-2803-9 ↗
5. L. Mollard, G. Destefanis, J. Rothman, N. Baier, S. Bisotto, P. Ballet, J.P. Chamonal, P. Castelein, J.P. Zanatta, M. Tchagaspanian, A.M. Papon, J.P. Barnes, F. Henry, S. Gout, G. Bourgeois, C. Pautet, and P. Fougères, HgCdTe FPAs made by arsenic-ion implantation. Infrared Technol. Appl. 1117, 6940 (2008). https://doi.org/10.1117/12.780582.10.1117/12.780582 ↗
6. C. Yildirim, P. Ballet, J.-L. Santailler, D. Giotta, R. Obrecht, T.N. Tran Thi, J. Baruchel, and D. Brellier, Role of threading dislocations on the growth of HgCdTe epilayers investigated using monochromatic x-ray Bragg diffraction imaging. J. Synchrotron Radiat. 28, 301 (2021). https://doi.org/10.1107/S1600577520014149.10.1107/S1600577520014149 ↗
7. C. Yildirim, E. Gout, A. Pagot, T.N. Tran-Thi-Caliste, J. Baruchel, D. Brellier, and P. Ballet, Bragg diffraction imaging of CdZnTe single crystals. J. Electron. Mater. 49(8), 4550 (2020). https://doi.org/10.1007/s11664-020-08219-2.10.1007/s11664-020-08219-2 ↗
8. T. Journot, D. Brellier, P. Ballet, T.N. Tran-Thi-Caliste, E. Gout, D. Collonge, and J. Baruchel, Combining Borrmann and weak-beam diffraction images to study defects in a high-quality CdTe(Zn) crystal. J. Appl. Crystallogr. 56(2), 401 (2023). https://doi.org/10.1107/S1600576723000377.10.1107/S1600576723000377 ↗
9. C. Lobre, P.-H. Jouneau, L. Mollard, and P. Ballet, Characterization of the microstructure of HgCdTe with p-type doping. J. Electron. Mater. 43(8), 2908 (2014). https://doi.org/10.1007/s11664-014-3147-9.10.1007/s11664-014-3147-9 ↗
10. A. Tuaz, P. Ballet, X. Biquard, and F. Rieutord, Micro-diffraction Investigation of localized strain in mesa-etched HgCdTe photodiodes. J. Electron. Mater. 46(9), 5442 (2017). https://doi.org/10.1007/s11664-017-5691-6.10.1007/s11664-017-5691-6 ↗
11. S. Bel, C. Lobre, S. Petit, M. Veillerot, and G. Badano, Characterization of intentional contaminations at the HgCdTe passivation interface and their effects on photodiode performance. J. Electron. Mater. 53(10), 5820 (2024). https://doi.org/10.1007/s11664-024-11137-2.10.1007/s11664-024-11137-2 ↗
12. O. Gravrand, C. Lobre, J-L, Santailler, N. Baier, W. Rabaud, A. Kerlain, D. Sam-Giao, P. Leboterf, B. Cornus, and L. Rubaldo, Design of a small pitch (7.5µm) MWIR HgCdTe array operating at high temperature (130K) with high imaging performances, in Infrared Technology and Applications XLIX, 2022, p. 26. https://doi.org/10.1117/12.2618852.10.1117/12.2618852 ↗
13. N. Baier, O. Gravrand, T. LeGoff, C. Lobre, W. Rabaud, F. Rochette, A. Brunner, C. Grezes, N. Morisset, and L. Rubaldo, Small pixel pitch MCT P on N MWIR photodiodes at DEFIR: towards 7.5 um and beyond with very high image quality, in Infrared Technology and Applications XLIX. p 35. https://doi.org/10.1117/12.2663760.10.1117/12.2663760 ↗
14. L. Rubaldo, N. Péré-Laperne, A. Brunner, N. Morisset, C. Cassillo, A. Kerlain, C. Grezes, G. Dagher, C. Martin, C. Lobre, O. Gravrand, P. Jenouvrier, and D. Billon-Lanfrey, Sub-10μm pitch HOT technologies development at LYNRED. Proc. SPIE. 12534, 33 (2023). https://doi.org/10.1117/12.2663462.10.1117/12.2663462 ↗
15. O. Gravrand, J. Rothman, C. Cervera, N. Baier, C. Lobre, J.P. Zanatta, O. Boulade, V. Moreau, and B. Fieque, HgCdTe detectors for space and science imaging: general issues and latest achievements. J. Electron. Mater. 45(9), 4532 (2016). https://doi.org/10.1007/s11664-016-4516-3.10.1007/s11664-016-4516-3 ↗
16. L. Mollard, G. Destefanis, G. Bourgeois, A. Ferron, N. Baier, O. Gravrand, J.P. Barnes, A.M. Papon, F. Milesi, A. Kerlain, and L. Rubaldo, Status of P-on-n arsenic-implanted HgCdTe technologies. J. Electron. Mater. 40, 1830 (2011). https://doi.org/10.1007/s11664-011-1692-z.10.1007/s11664-011-1692-z ↗
17. T. Le Goff, T. Pichon, N. Baier, O. Gravrand, and O. Boulade, Model and characterization of persistence in HgCdTe SWIR detectors for astronomy application. J. Electron. Mater. 51(10), 5586 (2022). https://doi.org/10.1007/s11664-022-09854-7.10.1007/s11664-022-09854-7 ↗
18. R. Smith, M. Zavodny, G. Rahmer, and M. Bonati, (2008) A theory for image persistence in HgCdTe photodiodes, Proc. SPIE 7021, High Energy, Optical, and Infrared Detectors for Astronomy III; 70210J. https://doi.org/10.1117/12.78937210.1117/12.789372 ↗
19. T. Le Goff, O. Gravrand, C. Lobre, O. Boulade, C. Ketchazo, and T. Pichon (2024) Very low-flux short-wave infrared FPAs developments at LETI for astronomy applications, in Proceedings SPIE 13103, x-ray, optical, and infrared detectors for astronomy XI, 131030Z. https://doi.org/10.1117/12.302093210.1117/12.3020932 ↗