journal article·2002-04

The microclimate analysis of tezone ‘105’ of the Venetian Arsenale

M. Strada, A. Carbonari, F. Peron, L. Porciani, P. Romagnoni

Journal of Cultural Heritage· Volume 3· Issue 1
Publisher page

Abstract

This paper presents a detailed analysis of the measured data on the indoor air of an historical building: tezone 105 of the Arsenale in Venice. During one year of measurements, the indoor air temperature and the air humidity have been collected: the probes have been placed in different sites in order to provide total control of the microclimate. The status of the internal walls has been checked by means of the measurement of the surface temperatures by different sets of thermal resistances. The data collected point out the water wall imbibition and the high thermal capacity of the building envelope. The collected information could be used for the design of the thermal system.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Building Energy and Comfort Optimization · Conservation Techniques and Studies · Building materials and conservation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (11)

Show source-provided references
1. Thomson · 1986
2. Bonacina · 1998
3. Sacchi · 1997
4. L'ambiente per la conservazione delle opere d'arte
5. Peron · 1997
6. 1999
7. Brown · 1995
8. Peron · 1997
9. Peron · 1998
10. Camuffo · 1998
11. Peron · 1999