journal article·2014-12

Oscillation analysis of a DFIG-based wind farm interfaced with LCC-HVDC

Lin Yang, XiangNing Xiao, ChengZong Pang

Publisher page

Abstract

With the increasing capacity of wind farm, HVDC technology has become a promising transmission scheme for long distance transportation of large-scale wind power. However oscillation caused by this system will have a great influence on the security and stability of power system operation. In this paper, the oscillation of a doubly-fed induction generator (DFIG)-based wind farm interfaced with line commutated converter (LCC) based HVDC is discussed. Low-frequency oscillation and subsynchronous oscillation (SSO) are studied since these two oscillations are the particularly concerned oscillations in the stability study of power system in recent years. The model of a DFIG-based wind farm interconnected with LCC-HVDC is developed. The impact of drive train model’s structure and parameters on the oscillation characteristics is analyzed. Eigenvalue and participation factor analysis are used to identify the three main modes, which include controller mode, electromechanical mode, and shaft mode. The effects of DFIG controller’s parameters, wind speed and operating conditions of HVDC on those modes are studied. Electromagnetic transient simulations are performed to verify the results of the eigenvalue analysis.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: HVDC Systems and Fault Protection · Wind Turbine Control Systems · Microgrid Control and Optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. Irwin G D, Jindal A K, Isaacs A L. Sub-synchronous control interactions between type 3 wind turbines and series compensated AC transmission systems. In: IEEE Power and Energy Society General Meeting. Detroit, 2011. 1–6
2. Moharana A, Varma R K, Seethapathy R. Modal analysis of Type-1 wind farm connected to series compensated transmission line and LCC HVDC transmission line. In: 2012 IEEE Electrical Power and Energy Conference. London, 2012. 202–20910.1109/EPEC.2012.6474951 ↗
3. Wang L, Thi M S N. Comparisons of damping controllers for stability enhancement of an offshore wind farm fed to an OMIB system through an LCC-HVDC link. IEEE T Power Syst, 2013, 28: 1870–187810.1109/TPWRS.2012.2231705 ↗
4. Guo D J, Wang L M, Han X G, et al. Study on transient stability of wind & thermal power transmission system based on PSS and SSSC (in Chinese). Power Syst Prot Contr, 2012, 40: 61–65
5. Yu Y X, Wang J R, Lv X Y. Security value based expansion planning of power system with integration of large-scale wind power. Sci China Tech Sci, 2012, 42: 815–829
6. Wang Y H, Huang B, Shen H, et al. Transmission capacity of grid-connecting channel for the second phase of 3 GW Jiuquan wind power base project and configuration of its reactive power compensation equipments (in Chinese). Power Syst Technol, 2013, 37: 1440–1446
7. Guo X J, Ma S Y, Shen H, et al. HVDC grid connection schemes and system stability control strategies for large-scale wind power (in Chinese). Autom Elec Power Syst, 2012, 36: 109–115
8. Zhou H L, Yang G, Wang J. Modeling, analysis, and control for the rectifier of hybrid HVdc systems for DFIG-Based wind farms. IEEE T Energy Conv, 2011, 26: 340–35310.1109/TEC.2010.2096819 ↗
9. Choo Y C, Agalgaonkar A P, Muttaqi K M, et al. Subsynchronous torsional interaction behaviour of wind turbine-generator unit connected to an HVDC system. In: IECON 2010-36th Annual Conference on IEEE Industrial Electronics Society. Glendale, 2010. 996–100210.1109/IECON.2010.5675504 ↗
10. Zhao S Q, Fan W. Power system forced power oscillation induced by wind speed disturbance in wind farms (in Chinese). East China Elec Power, 2009, 37: 98–102
11. Yang L H, Ma X K, Dai D. Low frequency oscillation in variable speed constant frequency doubly fed induction generator (in Chinese). J Xi’an Jiao Tong Univ, 2009, 43: 95–100
12. Chen S Y, Chang X P, Sun H D, et al. Impact of grid-connected wind farm on damping performance of power system (in Chinese). Power Syst Technol, 2013, 37: 1570–1577
13. Bi T S, Kong Y L, Xiao S W, et al. Review of sub-synchronous oscillation with large-scale wind power transmission (in Chinese). J Elec Power Sci Technol, 2012, 2: 10–15
14. Yan X B, Liu T Q, Li X Y, et al. Sub-synchronous resonance of large-scale wind farm (in Chinese). East China Elec Power, 2012, 40: 1328–1333
15. Lei H Y, Zheng C, Yue X H, et al. Mitigating thermal power’s SSR by additional damping controller of DFIG (in Chinese). Elec Power, 2013, 46: 63–68
16. Ostadi A, Yazdani A, Varma R K. Modeling and stability analysis of a DFIG-based wind-power generator interfaced with a series-compensated line. IEEE T Power Del, 2009, 24: 1504–151410.1109/TPWRD.2009.2013667 ↗
17. Fan L L, Zhu C X, Miao Z X, et al. Modal analysis of a DFIG-based wind farm interfaced with a series compensated network. IEEE T Energy Convers, 2011, 26: 1010–102010.1109/TEC.2011.2160995 ↗
18. Suriyaarachchi D H R, Annakkage U D, Karawita C, et al. A procedure to study sub-synchronous interactions in wind integrated power systems. IEEE T Power Syst, 2013, 28: 377–38410.1109/TPWRS.2012.2204283 ↗
19. Xiao X N, Yang L, Zhang D, et al. Analysis of subsynchronous damping conservation character based on eigenvalue method (in Chinese). Power Syst Technol, 2011, 35: 80–84
20. Anderson P M, Agrawal B L, Van Ness J E. Subsynchronous Resonance in Power Systems. New York: IEEE Press, 1989. 3–28
21. Kundur P. Power System Stability and Control. Beijing: China Electric Power Press, 2001. 700–726
22. Wang H S. Research on equivalent modelling of wind farms and transient operational performances (in Chinese). Dissertation of Masteral Degree. Chongqing: Chongqing Univ, 2010. 21–33
23. Slootweg J G, Kling W L. Aggregated modelling of wind parks in power system dynamics simulations. IEEE Bologna Power Tech Conference. Bologna, 2003. 1–6
24. Wu B, Lang Y Q, Zargari N, et al. Power Conversion and Control of Wind Energy System. Hoboken: John Wiley & Sons, 2011. 49–8610.1002/9781118029008.ch3 ↗
25. He Y K, Zheng K, Pan Z P, et al. Investigation on an AC excited variable-speed constant-frequency wind-power generation system (in Chinese). Autom Elec Power Syst, 2004, 28: 55–59
26. Szechtman M, Wess T, Thio C V. A benchmark model for HVDC system studies. In: International Conference on AC and DC Power Transmission. London, 1991. 374–378
27. Muyeen S M, Ali M H, Takahashi R, et al. Transient stability analysis of wind generator system with the consideration of multi-mass shaft model. In: International Conference on PEDS. Kuala Lumpur, 2005. 511–516
28. Li H, Ye R J, Gao Q, et al. Influence of models and parameters on transient performances of a wind turbine with DFIG (in Chinese). Elec Mach Control, 2010, 14: 24–30
29. Muyeen S M, Ali M H, Takahashi R, et al. Comparative study on transient stability analysis of wind turbine generator system using different drive train models. IET Renew Power Gener, 2007, 1: 131–14110.1049/iet-rpg:20060030 ↗
30. Anaya-lara O, Jenkins N, Ekanayake J, et al. Wind Energy Generation Modelling and Control. Hoboken: John Wiley & Sons, 2009. 121–134
31. Liao Y, Wang G D. VSC-HVDC system control for grid-connection of DIFG wind farms (in Chinese). Proc CSEE, 2012, 32: 7–15
32. Zhao Y, Zheng B Y, He Z Y. The control mode and operating performance of Nanhui VSC-HVDC Demonstration Project (in Chinese). Southern Power Syst Technol, 2012, 6: 6–10
33. Zheng C, Teng S, Song X L, et al. Analysis on system characteristics after incorporation of ±320 kV/1000 MW VSC-HVDC into Dalian power grid (in Chinese). Autom Elec Power Syst, 2013, 37: 15–19
34. Li W J, Tang G F, He Z Y. Control strategies of DFIG-based wind farm grid integration using modular multilevel VSC-HVDC technology (in Chinese). Autom Elec Power Syst, 2013, 37: 20–26
35. Qin C, Ju P, Wu F, et al. Distinguishability analysis of controller parameters with applications to DFIG based wind turbine. Sci China Tech Sci, 2013, 56: 2465–247210.1007/s11431-013-5324-0 ↗