journal article·2014-10

Low-field NMR micro coils based on printed circuit board technology

WeiPing Wu, RongSheng Lu, XinLong Zhou, YunYi Zhang, ZhongHua Ni

Publisher page

Abstract

Radiofrequency coil is one of the most important components for a nuclear magnetic resonance (NMR) instrument. In this article, some planar micro coils with an inner diameter of 2 mm and number of turns that varied from 1 to 11 were investigated based on the printed circuit board (PCB) technology. The electrical characterization of micro coils show that self-resonant frequencies are larger than 200 MHz. Then, an NMR measurement platform with a static magnetic field of 0.66 T was constructed and the signal to noise ratio (SNR) values of the NMR were analyzed. It was found that the SNR is optimal when the turn number of the micro coils is six and the excitation time of a 90° pulse is 0.8 ms. Finally, we used the micro coil with six turns to study the transverse relaxation rate of copper sulfate pentahydrate aqueous solution with different concentrations. It was found that the transverse relaxation rate is proportional to the solution concentration. Results from the micro coil were verified by measurements using a Bruker Minispec MQ60.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced MRI Techniques and Applications · NMR spectroscopy and applications · Advanced NMR Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. Bajaj V S, Paulsen J, Harel E, et al. Zooming in on microscopic flow by remotely detected MRI. Science, 2010, 330: 1078–108110.1126/science.1192313 ↗
2. Arai M, Ferreon J C, Wright P E. Quantitative analysis of multisite protein-ligand interactions by NMR: Binding of intrinsically disordered p53 transactivation subdomains with the TAZ2 domain of CBP. J Am Chem Soc, 2012, 134: 3792–380310.1021/ja209936u ↗
3. Kitevski-LeBlanc J L, Prosser R S. Current applications of 19F NMR to studies of protein structure and dynamics. Prog Nucl Magn Reson Spectrosc, 2012, 62: 1–3310.1016/j.pnmrs.2011.06.003 ↗
4. Hoult D I, Richards R E. The signal-to-noise ratio of the nuclear magnetic resonance experiment. J Magn Reson, 1976, 24: 71–85
5. Magin R L, Webb A G, Peck T L. Miniature magnetic resonance machines. IEEE Spectrum, 1997, 34: 51–6110.1109/6.625252 ↗
6. Wright A C, Neideen T A, Magin R L, et al. Evaluation of radio frequency microcoils as nuclear magnetic resonance detectors in low-homogeneity high-field superconducting magnets. Rev Sci Instrum, 1998, 69: 3938–394110.1063/1.1149201 ↗
7. Moresi G, Magin R. Miniature permanent magnet for table-top NMR. Concepts Magn Reson Part B, 2003, 19B: 35–4310.1002/cmr.b.10082 ↗
8. Peck T L, Magin R L, Lauterbur P C. Design and analysis of microcoils for NMR microscopy. J Magn Reson Ser B, 1995, 108: 114–12410.1006/jmrb.1995.1112 ↗
9. Massin C, Boero C, Vincent F, et al. High-Q factor RF planar microcoils for micro-scale NMR spectroscopy. Sens Actuator A Phys, 2002, 97–98: 280–28810.1016/S0924-4247(01)00847-0 ↗
10. Massin C, Vincent F, Homsy A, et al. Planar microcoil-based microfluidic NMR probes. J Magn Reson, 2003, 164: 242–25510.1016/S1090-7807(03)00151-4 ↗
11. Hsieh C, Yeh Y, Fan L. Multilayer high-aspect-ratio RF coil for NMR applications. Microsyst Technol, 2011, 17: 1311–131710.1007/s00542-011-1305-z ↗
12. Lam M H C, Homenuke M A, Michal C A, et al. Sub-nanoliter nuclear magnetic resonance coils fabricated with multilayer soft lithography. J Micromech Microeng, 2009, 19: 09500110.1088/0960-1317/19/9/095001 ↗
13. Nguyen N T, Huang X Y. Miniature valveless pumps based on printed circuit board technique. Sens Actuator A-Phys, 2001, 88: 104–11110.1016/S0924-4247(00)00500-8 ↗
14. Gassmann S, Ibendorf I, Pagel L. Realization of a flow injection analysis in PCB technology. Sens Actuator A-Phys, 2007, 133: 231–23510.1016/j.sna.2006.04.009 ↗
15. Kong T F, Peng W K, Luong T D, et al. Adhesive-based liquid metal radio-frequency microcoil for magnetic resonance relaxometry measurement. Lab Chip, 2012, 12: 287–29410.1039/C1LC20853E ↗
16. Wensink H, Hermes D C, van den Berg A. High signal to noise ratio in low field NMR on chip, simulations and experimental results. In: 17th IEEE International Conference on Micro Electro Mechanical Systems, Maastricht, the Netherlands, 200410.1109/MEMS.2004.1290608 ↗
17. Wensink H, Benito-Lopez F, Hermes D C, et al. Measuring reaction kinetics in a lab-on-a-chip by microcoil NMR. Lab Chip, 2005, 5: 280–28410.1039/b414832k ↗
18. Fratila R M, Velders A H. Small-volume nuclear magnetic resonance spectroscopy. Ann Rev Anal Chem, 2011, 4: 227–24910.1146/annurev-anchem-061010-114024 ↗
19. Kratt K, Badilita V, Burger T, et al. A fully MEMS-compatible process for 3D high aspect ratio micro coils obtained with an automatic wire bonder. J Micromech Microeng, 2010, 20: 01502110.1088/0960-1317/20/1/015021 ↗
20. Spengler N, Moazenzadeh A, Meier R C, et al. Micro-fabricated Helmholtz coil featuring disposable microfluidic sample inserts for applications in nuclear magnetic resonance. J Micromech Microeng, 2014, 24: 03400410.1088/0960-1317/24/3/034004 ↗
21. Sillerud L O, McDowell A F, Adolphi N L, et al. H-1 NMR Detection of superparamagnetic nanoparticles at 1 T using a microcoil and novel tuning circuit. J Magn Reson, 2006, 181: 181–19010.1016/j.jmr.2006.04.005 ↗
22. Seeber D A, Cooper R L, Ciobanu L, et al. Design and testing of high sensitivity microreceiver coil apparatus for nuclear magnetic resonance and imaging. Rev Sci Instrum, 2001, 72: 2171–217910.1063/1.1359190 ↗
23. Manz B, Benecke M, Volke F. A simple, small and low cost permanent magnet design to produce homogeneous magnetic fields. J Magn Reson, 2008, 192: 131–13810.1016/j.jmr.2008.02.011 ↗