Research trend of cascade heat pumps

Samuel Boahen, JongMin Choi

Publisher page

Abstract

Most commercial and industrial facilities require very low temperatures for refrigeration and high temperatures for space heating and hot water purposes. Single stage heat pumps have not been able to meet these temperature demands and have been characterized by low capacities and coefficient of performance (COP). Cascade heat pump has been developed to overcome the weaknesses of single stage heat pumps. This study reviews recent works done by researchers on cascade heat pumps for refrigeration, heating and hot water generation. Selection of suitable refrigerants to meet the pressure and temperature demands of each stage of the cascade heat pump has been discussed. Optimization of design parameters such as intermediate temperature (low stage condensing and high stage evaporating temperatures), and temperature difference in the cascade heat exchanger for optimum performance of the cascade heat pump has been reviewed. It was found that optimising each design parameter of the cascade heat pump is necessary for maximum system performance and this may improve the exergetic efficiency, especially of cascade refrigeration systems, by about 30.88%. Cascade heat pumps have wider range of application especially for artificial snow production, in the supermarkets, for natural gas liquefaction, in drying clothes and food and as heat recovery system. The performance of cascade heat pumps can be improved by 19% when coupled with other renewable energy sources for various real time applications. Also, there is the need for much research on refrigerant charge amount of cascade heat pumps, refrigerant-refrigerant heat exchangers to be used as cascade heat exchanger, cascade heat pumps for simultaneous cooling, heating and hot water generation and on the use of variable speed compressors and their control strategies in matching system capacity especially at part load conditions.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Refrigeration and Air Conditioning Technologies · Heat Transfer and Boiling Studies · Heat Transfer and Optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (74)

Show source-provided references
1. Cho C, Min Choi J. Experimental investigation of a multi-function heat pump under various operating modes. Renew Energy, 2013, 54: 253–25810.1016/j.renene.2012.07.017 ↗
2. Johnstone N, Haščič I, Popp D. Renewable energy policies and technological innovation: Evidence based on patent counts. Environ Resour Econ, 2010, 45: 133–15510.1007/s10640-009-9309-1 ↗
3. Aikins K A, Lee S H, Choi J M. Technology review of two-stage vapor compression heat pump system. Int J Air-Cond Ref, 2013, 21: 133000210.1142/S2010132513300024 ↗
4. Zubair S M, Yaqub M, Khan S H. Second-law-based thermodynamic analysis of two-stage and mechanical-subcooling refrigeration cycles. Int J Refrig, 1996, 19: 506–51610.1016/S0140-7007(96)00045-X ↗
5. Jung H W, Kang H, Yoon W J, et al. Performance comparison between a single-stage and a cascade multi-functional heat pump for both air heating and hot water supply. Int J Refrig, 2013, 36: 1431–144110.1016/j.ijrefrig.2013.03.003 ↗
6. Hosoz M. Performance comparison of single-stage and cascade refrigeration systems using R134a as the working fluid. Turkish J Eng Env Sci, 2005, 29: 285–296
7. Wang B M, Xing Z W, Wu H G. Experimental study on the performance of a twin-screw CO2 compressor in NH3/CO2 cascade refrigeration system. P I Mech Eng A-J Pow, 2010, 224: 1141–1146
8. Kim D H, Park H S, Kim M S. Optimal temperature between high and low stage cycles for R134a/R410A cascade heat pump based water heater system. Exp Thermal Fluid Sci, 2013, 47: 172–17910.1016/j.expthermflusci.2013.01.013 ↗
9. Corberán J M, Martínez-Galván I, Martínez-Ballester S, et al. Influence of the source and sink temperatures on the optimal refrigerant charge of a water-to-water heat pump. Int J Refrig, 2011, 34: 881–89210.1016/j.ijrefrig.2011.01.009 ↗
10. Jeong K, Choi J M. Capacity modulation of a cascade heat pump with the variation of compressor speed and electronic expansion valve opening. J Renew Sustain Energy, 2014, 6: 05310710.1063/1.4896597 ↗
11. Di Nicola G, Giuliani G, Polonara F, et al. Blends of carbon dioxide and HFCs as working fluids for the low-temperature circuit in cascade refrigerating systems. Int J Refrig, 2005, 28: 130–14010.1016/j.ijrefrig.2004.06.014 ↗
12. Messineo A, Panno D. Performance evaluation of cascade refrigeration systems using different refrigerants. Int J Air-Cond Ref, 2012, 20: 125001010.1142/S2010132512500101 ↗
13. Bhattacharyya S, Garai A, Sarkar J. Thermodynamic analysis and optimization of a novel N2O-CO2 cascade system for refrigeration and heating. Int J Refrig, 2009, 32: 1077–108410.1016/j.ijrefrig.2008.09.008 ↗
14. Sarkar J, Bhattacharyya S, Gopal M R. Optimization of a transcritical CO2 heat pump cycle for simultaneous cooling and heating applications. Int J Refrig, 2004, 27: 830–83810.1016/j.ijrefrig.2004.03.006 ↗
15. Bhattacharyya S, Mukhopadhyay S, Kumar A, et al. Optimization of a CO2–C3H8 cascade system for refrigeration and heating. Int J Refrig, 2005, 28: 1284–129210.1016/j.ijrefrig.2005.08.010 ↗
16. Bhattacharyya S, Mukhopadhyay S, Sarkar J. CO2-C3H8 cascade refrigeration-heat pump system: Heat exchanger inventory optimization and its numerical verification. Int J Refrig, 2008, 31: 1207–121310.1016/j.ijrefrig.2008.02.003 ↗
17. Dubey A M, Kumar S, Agrawal G D. Thermodynamic analysis of a transcritical CO2/propylene (R744-R1270) cascade system for cooling and heating applications. Energy Conv Manage, 2014, 86: 774–78310.1016/j.enconman.2014.05.105 ↗
18. Yu P C. Refrigerant selection for sustainable future. ASHRAE J, 2007-2008: 22–26
19. Billiard F. Selection of refrigerants on a per-application basis: Trends. Int Inst Refrig, 2002, 1(2005): 7
20. Bansal P, Jain S. Cascade systems: Past, present, and future. Trans ASHRAE, 2007, 113: 245–252
21. Lommers C A. Air Conditioning and Refrigeration Industry Refrigerant Selection Guide-2003. 7th Ed. Melbourne Vic: Australian Institute of Refrigeration Air Conditioning and Heating Inc. (AIRAH), 2003
22. Xu X. Refrigerant selection in room air conditioning industry for sustainable development. Dissertation of Masteral Degree. Tokyo: The University of Tokyo, 2012
23. Bensafi A, Thonon B. Transcritical R744 (CO2) Heat Pumps Technician’s Manual. Villeurbanne Cedex-France: Centre Technique Des Industries Aérauliques Et Thermiques, 2007
24. Dopazo J A, Fernández-Seara J. Experimental evaluation of a cascade refrigeration system prototype with CO2 and NH3 for freezing process applications. Int J Refrig, 2011, 34: 257–26710.1016/j.ijrefrig.2010.07.010 ↗
25. Sarker J, Bhattacharyya S, Lal A. Selection of suitable natural refrigerants pairs for cascade refrigeration system. P I Mech Eng A-J Pow, 2013, 227: 612–622
26. Ouadha A, En-Nacer M, Imine O, er al. Exergy analysis and comparision of two-stage and cascade refrigeration cycles using natural refrigerants. In: Proceedings of the Heat-SET, Heat Transfer in Components and systems for sustainable Energy Technologies Conference. Le Bourget du Lac, France, 2007
27. Messineo A. R744-R717 cascade refrigeration system: Performance evaluation compared with a HFC two-stage system. Energy Procedia, 2012, 14: 56–6510.1016/j.egypro.2011.12.896 ↗
28. Jadhav J S, Apte A D. Review of cascade refrigeration system with different refrigerant pairs. Int J Innov Eng Res Technol, 2015, 2: 74–81
29. Chae J H, Choi J M. Evaluation of the impacts of high stage refrigerant charge on cascade heat pump performance. Renew Energy, 2015, 79: 66–7110.1016/j.renene.2014.07.042 ↗
30. Kim D H, Park H S, Kim M S. The effect of the refrigerant charge amount on single and cascade cycle heat pump systems. Int J Refrig, 2014, 40: 254–26810.1016/j.ijrefrig.2013.10.002 ↗
31. Kim D H, Park H S, Kim M S. Characteristics of R134a/R410A cascade heat pump and optimization. In: Proceedings of the International Refrigeration and Air Conditioning Conference. West Lafayette, IN, 2012
32. Kilicarslan A, Hosoz M. Energy and irreversibility analysis of a cascade refrigeration system for various refrigerant couples. Energ Conv Manage, 2010, 51: 2947–295410.1016/j.enconman.2010.06.037 ↗
33. Bingming W, Huagen W, Jianfeng L, et al. Experimental investigation on the performance of NH3/CO2 cascade refrigeration system with twin-screw compressor. Int J Refrig, 2009, 32: 1358–136510.1016/j.ijrefrig.2009.03.008 ↗
34. Choi J M, Kim Y C. The effects of improper refrigerant charge on the performance of a heat pump with an electronic expansion valve and capillary tube. Energy, 2002, 27: 391–40410.1016/S0360-5442(01)00093-7 ↗
35. Park H, Kim D H, Kim M S. Thermodynamic analysis of optimal intermediate temperatures in R134a-R410A cascade refrigeration systems and its experimental verification. Appl Thermal Eng, 2013, 54: 319–32710.1016/j.applthermaleng.2013.01.005 ↗
36. Ratts E B, Brown J S. A generalized analysis for cascading single fluid vapor compression refrigeration cycles using an entropy generation minimization method. Int J Refrig, 2000, 23: 353–36510.1016/S0140-7007(99)00070-5 ↗
37. Agnew B, Ameli S M. A finite time analysis of a cascade refrigeration system using alternative refrigerants. Appl Thermal Eng, 2004, 24: 2557–256510.1016/j.applthermaleng.2004.03.013 ↗
38. Ma M, Yu J, Wang X. Performance evaluation and optimal configuration analysis of a CO2/NH3 cascade refrigeration system with falling film evaporator-condenser. Energy Conv Manage, 2014, 79: 224–23110.1016/j.enconman.2013.12.021 ↗
39. Parekh A D, Tailor P R. Thermodynamic analysis of R507A-R23 cascade refrigeration system. Int Scho Sci Res Innov, 2011, 5: 1919–1923
40. Fiora J J, Lima C U S, Junior V S. Theoritic-experimental evaluation of a cascade refrigeration system for low temperature applications using the pair R22/R404A. Therm Eng, 2012, 11: 7–14
41. Lee T S, Liu C H, Chen T W. Thermodynamic analysis of optimal condensing temperature of cascade-condenser in CO2/NH3 cascade refrigeration systems. Int J Refrig, 2006, 29: 1100–110810.1016/j.ijrefrig.2006.03.003 ↗
42. Lee T S, Liu C H, Chen T W. Thermodynamic analysis of optimum condensing temperature of cascade condenser for CO2/NH3 cascade refrigeration systems. In: IIR Ammonia Refrigeration Conference. Ohrid, Republic of Macedonia, 2005
43. Getu H M, Bansal P K. Thermodynamic analysis of an R744–R717 cascade refrigeration system. Int J Refrig, 2008, 31: 45–5410.1016/j.ijrefrig.2007.06.014 ↗
44. Sachdeva G, Jain V, Kachhwaha S S. Performance study of cascade refrigeration system using alternative refrigerants. Int Scho Sci Res Innov, 2014, 8: 522–528
45. Alberto Dopazo J, Fernández-Seara J, Sieres J, et al. Theoretical analysis of a CO2-NH3 cascade refrigeration system for cooling applications at low temperatures. Appl Thermal Eng, 2009, 29: 1577–158310.1016/j.applthermaleng.2008.07.006 ↗
46. Kilicarslan A. An experimental investigation of a different type vapor compression cascade refrigeration system. Appl Thermal Eng, 2004, 24: 2611–262610.1016/j.applthermaleng.2004.04.004 ↗
47. Soltani R, Dincer I, Rosen M A. Comparative performance evaluation of cascaded air-source hydronic heat pumps. Energy Conv Manage, 2015, 89: 577–58710.1016/j.enconman.2014.10.006 ↗
48. Swanson A G, Carlson A C. Performance and energy savings of variable refrigerant technology in cold weather climates. Conservation Applied Research and Development Final Report. Minnesota Department of Commerce, Division if Energy Resources, Minnesota, USA, 2015
49. Jung H W, Kang H, Chung H, et al. Performance optimization of a cascade multi-functional heat pump in various operation modes. Int J Refrig, 2014, 42: 57–6810.1016/j.ijrefrig.2014.03.004 ↗
50. Tassou S A, Qureshi T Q. Comparative performance evaluation of positive displacement compressors in variable-speed refrigeration applications. Int J Refrig, 1998, 21: 29–4110.1016/S0140-7007(97)00082-0 ↗
51. Adhikari R S, Aste N, Manfren M, et al. Energy savings through variable speed compressor heat pump systems. Energy Procedia, 2012, 14: 1337–134210.1016/j.egypro.2011.12.1098 ↗
52. Ekren O, Celik S, Noble B, et al. Performance evaluation of a variable speed DC compressor. Int J Refrig, 2013, 36: 745–75710.1016/j.ijrefrig.2012.09.018 ↗
53. Arouca L B P, Almeida A G S, Almeida F S, et al. Exergy analysis of cascade refrigeration system for low temperatures using ecological fluids. In: Proceedings of 22nd International Congress of Mechanical Engineering. Ribeirão Preto, SP, 2013. 10221–10230
54. Bhattacharyya S, Bose S, Sarkar J. Exergy maximization of cascade refrigeration cycles and its numerical verification for a transcritical CO2-C3H8 system. Int J Refrig, 2007, 30: 624–63210.1016/j.ijrefrig.2006.11.008 ↗
55. Yilmaz B, Erdonmez N, Sevindir M K, Mancuhan E. Thermodynamic analysis and optimization of cascade condensing temperature of a CO2 (R744)/R404A cascade refrigeration system. In: International Refrigeration and Air Conditioning Conference. West Lafayette, IN: Herrick Laboratories, Purdue University, 2014
56. Mafi M, Naeynian S M M, Amidpour M. Exergy analysis of multistage cascade low temperature refrigeration systems used in olefin plants. Int J Refrig, 2009, 32: 279–29410.1016/j.ijrefrig.2008.05.008 ↗
57. Pereira C, Lequisiga D. Technical evaluation of C3-MR and cascade cycle on natural gas liquefaction process. Int J Chem Eng Appl, 2014, 5: 451–456
58. Refrigeration technology for sports and leisure facilities. GEA Refrigeration Technologies. http://www.gea.com/en/binaries/Ap_Leisure_150dpi_A4Size_4C_US_tcm11-18513.pdf
59. Sharma V, Fricke B, Bansal P. Comparative analysis of various CO2 configurations in supermarket refrigeration systems. Int J Refrig, 2014, 46: 86–9910.1016/j.ijrefrig.2014.07.001 ↗
60. Baxter V D. IEA annex 26: Advanced supermarket refrigeration/heat recovery system. IEA Annex 26 Final Report. Canada-Denmark-Sweden-United Kingdom-United States, 2003
61. Sánchez D, Llopis R, Cabello R, et al. Conversion of a direct to an indirect commercial (HFC134a/CO2) cascade refrigeration system: Energy impact analysis. Int J Refrig, 2017, 73: 183–19910.1016/j.ijrefrig.2016.09.012 ↗
62. Yoon J I, Lee H S, Oh S T, et al. Characteristics of cascade and C3MR cycle on natural gas liquefaction process. Int Scho Sci Res Innov, 2009, 59: 620–624
63. Hwang I S, Lee Y L. Cascade heat pump dryer performance improvement using a solar collector. ARPN J Eng Appl Sci, 2015, 10: 782–787
64. Kondou C, Koyama S. Thermodynamic assessment of high-temperature heat pumps using Low-GWP HFO refrigerants for heat recovery. Int J Refrig, 2015, 53: 126–14110.1016/j.ijrefrig.2014.09.018 ↗
65. IEA Annex 35: Applications of Industrial heat pumps. IEA Heat pump programme Annex 35. Final Report. Boras, Sweden, 2014
66. Du K, Zhang S, Xu W, et al. A study on the cycle characteristics of an auto-cascade refrigeration system. Exp Thermal Fluid Sci, 2009, 33: 240–24510.1016/j.expthermflusci.2008.08.006 ↗
67. Zhang J, Xu Q. Cascade refrigeration system synthesis based on exergy analysis. Comp Chem Eng, 2011, 35: 1901–191410.1016/j.compchemeng.2011.02.015 ↗
68. Fernández-Seara J, Sieres J, Vázquez M. Compression-absorption cascade refrigeration system. Appl Thermal Eng, 2006, 26: 502–51210.1016/j.applthermaleng.2005.07.015 ↗
69. Park N, Woo H S, Ha J C, et al. On the optimal water discharge temperature of air-to-water heat pump for space heating and domestic hot water. In: Proceedings of International Refrigeration and Air Conditioning Conference. West Lafayette, IN, 2010. 2497
70. Kaushik S C, Kumar P, Jain S. Performance evaluation of irreversible cascaded refrigeration and heat pump cycles. Energy Conv Manage, 2002, 43: 2405–242410.1016/S0196-8904(01)00172-8 ↗
71. Аndriy R. Thermodynamic analysis of cycles of the cascade heat pump plant. In: Proceedings of the Thirty-sixth Workshop on Geothermal Reservoir Engineering. Stanford, California, 2011
72. Rezayan O, Behbahaninia A. Thermoeconomic optimization and exergy analysis of CO2/NH3 cascade refrigeration systems. Energy, 2011, 36: 888–89510.1016/j.energy.2010.12.022 ↗
73. Wu J, Yang Z, Wu Q, et al. Transient behavior and dynamic performance of cascade heat pump water heater with thermal storage system. Appl Energy, 2012, 91: 187–19610.1016/j.apenergy.2011.09.020 ↗
74. Madani H, Claesson J, Lundqvist P. Capacity control in ground source heat pump systems part II: Comparative analysis between on/off controlled and variable capacity systems. Int J Refrig, 2011, 34: 1934–194210.1016/j.ijrefrig.2011.05.012 ↗