Fast and selective cell isolation from blood sample by microfiber fabric system with vacuum aspiration
Source abstract
Abstract
Since circulating tumor cells (CTCs) are tumor cells which are found in the blood of cancer patients, CTCs are potential tumor markers, so a rapid isolation of CTCs is desirable for clinical applications. In this paper, a three-dimensional polystyrene (PS) microfiber fabric with vacuum aspiration system was developed for capturing CTCs within a short time. Various microfiber fabrics with different diameters were prepared by the electrospinning method and optimized for contact frequency with cells. Vacuum aspiration utilizing these microfiber fabrics could filter all cells within seconds without mechanical damage. The microfiber fabric with immobilized anti-EpCAM antibodies was able to specifically capture MCF-7 cells that express EpCAM on their surfaces. The specificity of the system was confirmed by monitoring the ability to isolate MCF-7 cells from a mixture containing CCRF-CEM cells that do not express EpCAM. Furthermore, the selective capture ability of the microfiber was retained even when the microfiber was exposed to the whole blood of pigs spiked with MCF-7 cells. The specific cell capture ratio of the vacuum aspiration system utilizing microfiber fabric could be improved by increasing the thickness of the microfiber fabric through electrospinning time.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: 3D Printing in Biomedical Research · Microfluidic and Bio-sensing Technologies · Cancer Cells and Metastasis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Bioengineering, The University of Tokyo, Tokyo, Japan
Department of Immunology, Genetics and Pathology (IGP), Uppsala University, Uppsala, Sweden
References (24)
Show source-provided references
1. 10.1073/pnas.150448411210.1073/pnas.1504484112 ↗
2. 10.1158/1078-0432.CCR-04-037810.1158/1078-0432.CCR-04-0378 ↗
3. 10.1016/S0090-4295(01)01191-810.1016/S0090-4295(01)01191-8 ↗
4. 10.1007/s12282-009-0139-310.1007/s12282-009-0139-3 ↗
5. 10.1038/nrc237510.1038/nrc2375 ↗
6. 10.1056/NEJMoa080066810.1056/NEJMoa0800668 ↗
7. 10.1126/science.125353310.1126/science.1253533 ↗
8. 10.1073/pnas.95.8.458910.1073/pnas.95.8.4589 ↗
9. 10.1080/1040836059091369610.1080/10408360590913696 ↗
10. 10.1007/s00109990003810.1007/s001099900038 ↗
11. 10.1038/sj.bjc.660292410.1038/sj.bjc.6602924 ↗
12. 10.1016/j.humpath.2003.08.02610.1016/j.humpath.2003.08.026 ↗
13. 10.1002/adma.20120318510.1002/adma.201203185 ↗
14. 10.1038/nprot.2014.04410.1038/nprot.2014.044 ↗
15. 10.1038/nature0638510.1038/nature06385 ↗
16. 10.1021/ac101222x10.1021/ac101222x ↗
17. 10.1016/j.snb.2013.04.03010.1016/j.snb.2013.04.030 ↗
18. 10.1039/C3LC50689D10.1039/C3LC50689D ↗
19. 10.1002/pros.v73.810.1002/pros.v73.8 ↗
20. 10.1007/s10544-010-9485-310.1007/s10544-010-9485-3 ↗
21. 10.1063/1.37353210.1063/1.373532 ↗
22. 10.1016/S0887-7963(05)80053-710.1016/S0887-7963(05)80053-7 ↗
23. Takai M · Proc Micro-TAS · 2011 · 1209
24. 10.1111/vox.1989.57.issue-310.1111/vox.1989.57.issue-3 ↗