journal article·2004-07

Improving the Refractory Lining Durability of Pyrometallurgical Plants in Service at the Svyatogor Joint-Stock Co.

V. G. Kozhin, V. V. Belyaev, E. N. Selivanov

Publisher page

Abstract

Factors responsible for the failure of the refractory brick lining of pyrometallurgical plants in service at the Svyatogor JSC are considered, of which the major ones are: corrosion due to the attack from high-iron silicon-containing slag, infiltration of molten mass causing fracture during the heat-and-cool thermal cycling, and mechanical impact. Measures that allowed the refractory consumption rate to be reduced to 0.035 tons per ton of blister copper are described.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Material Properties and Applications · Diverse Industrial Engineering Technologies · Industrial Engineering and Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (5)

Show source-provided references
1. A. P. Snurnikov and S. N. Makarova, "Techniques for cooling the lining of oxyacetylene apparatuses," Tsvetn. Met., No. 8, 35-37 (1989).
2. B. M. Lepinskikh, A. A. Belousov, S. G. Bakhvalov, and A. A. Vostryakov, Transport Properties of Molten Metal and Slag [in Russian], Metallurgiya, Moscow (1995).
3. E. N. Selivanov, "Nickel matte-impregnated magnesite-chromite lining," Ogneupory, No. 6, 28-29 (1995).
4. V. K. Yakushev, I. V. Basina, T. V. Dodis, et al., "Warmup rate and thermal stability of the lining for thermal power units," Kompleks. Ispol'zovanie Mineral. Syr'ya (Comprehensive Raw Mineral Processing), No. 1, 68-70 (1982).
5. V. G. Kozhin, V. V. Belyaev, and N. A. Morozov, "Converter technology in practice at the Svyatogor JSC," Tsvetn. Metallurgiya, No. 6, 17-20 (2002).