An instrumented scaffold can monitor loading in the knee joint
Source abstract
Abstract
Abstract No technique has been consistently successful in the repair of large focal defects in cartilage, particularly in older patients. Tissue‐engineered cartilage grown on synthetic scaffolds with appropriate mechanical properties will provide an implant, which could be used to treat this problem. A means of monitoring loads and pressures acting on cartilage, at the defect site, will provide information needed to understand integration and survival of engineered tissues. It will also provide a means of evaluating rehabilitation protocols. A “sensate” scaffold with calibrated strain sensors attached to its surface, combined with a subminiature radio transmitter, was developed and utilized to measure loads and pressures during gait. In an animal study utilizing six dogs, peak loads of 120N and peak pressures of 11 MPa were measured during relaxed gait. Ingrowth into the scaffold characterized after 6 months in vivo indicated that it was well anchored and bone formation was continuing. Cartilage tissue formation was noted at the edges of the defect at the joint–scaffold interfaces. This suggested that native cartilage integration in future formulations of this scaffold configured with engineered cartilage will be a possibility. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Osteoarthritis Treatment and Mechanisms · Knee injuries and reconstruction techniques · Total Knee Arthroplasty Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. Articular cartilage: Degeneration and osteoarthritis, repair, regeneration, and transplantation
2. 10.1053/joca.2002.080110.1053/joca.2002.0801 ↗
3. 10.1016/j.biomaterials.2003.10.05610.1016/j.biomaterials.2003.10.056 ↗
4. Millenium Research Group Inc. US markets for orthopedic biomaterials USBO 01 Millenium Group Toronto Ontario 2002.www.mrg.net
5. 10.1016/S0736-0266(00)90015-910.1016/S0736-0266(00)90015-9 ↗
6. 10.1177/0363546502030001160110.1177/03635465020300011601 ↗
7. 10.1097/00003086-200110001-0003110.1097/00003086-200110001-00031 ↗
8. 10.1097/00003086-199910001-0001910.1097/00003086-199910001-00019 ↗
9. 10.1097/00003086-200110001-0001610.1097/00003086-200110001-00016 ↗
10. 10.1016/S0142-9612(99)00073-310.1016/S0142-9612(99)00073-3 ↗
11. 10.1016/S0142-9612(00)00201-510.1016/S0142-9612(00)00201-5 ↗
12. 10.1016/S0142-9612(00)00211-810.1016/S0142-9612(00)00211-8 ↗
13. 10.1023/A:102036110985910.1023/A:1020361109859 ↗
14. 10.1002/mabi.20030001710.1002/mabi.200300017 ↗
15. Quantification of tissue scaffold structural strains
16. 10.1016/S0736-0266(02)00024-410.1016/S0736-0266(02)00024-4 ↗
17. Strong porous polymer‐ceramic composites by rapid prototyping for resorbable orthopedic scaffold applications
18. 10.1002/jbm.b.3017710.1002/jbm.b.30177 ↗
19. Tellis BC · 2006 · 838
20. Szivek JA · 2004 · 1254
21. 10.1002/(SICI)1097-4636(199824)43:4<462::AID-JBM14>3.0.CO;2-J10.1002/(SICI)1097-4636(199824)43:4<462::AID-JBM14>3.0.CO;2-J ↗
22. 10.1002/(SICI)1097-4636(1999)48:1<32::AID-JBM7>3.0.CO;2-X10.1002/(SICI)1097-4636(1999)48:1<32::AID-JBM7>3.0.CO;2-X ↗
23. 10.3109/0894193920901242610.3109/08941939209012426 ↗
24. 10.3109/0894193970903216510.3109/08941939709032165 ↗
25. 10.1097/00007632-200203010-0000910.1097/00007632-200203010-00009 ↗
26. 10.1016/S0883-5403(96)80137-910.1016/S0883-5403(96)80137-9 ↗
27. 10.3109/1052029870910803010.3109/10520298709108030 ↗
28. 10.1055/s-2001-1923610.1055/s-2001-19236 ↗
29. Comparison of force of foot between quadrupedal walking of dog and bipedal walking man
30. Force plate analysis of the walking gait in healthy dogs
31. 10.3109/1745367880914878810.3109/17453678809148788 ↗
32. 10.1002/jor.110009041210.1002/jor.1100090412 ↗