journal article·2008-07

Y‐TZP zirconia run against highly crosslinked UHMWPE tibial inserts: Knee simulator wear and phase‐transformation studies

Riichiro Tsukamoto, Paul A. Williams, Ian C. Clarke, Giuseppe Pezzotti, Hiromu Shoji, Masao Akagi, Kengo Yamamoto

Publisher page

Abstract

Abstract Background: Zirconia (ZrO2) ceramics combined with highly cross‐linked polyethylene appears to be a promising approach to minimize wear in artificial knee joints. The wear performance of yttria‐stabilized zirconia (YZr) femoral condyles on 7‐Mrad tibial inserts was compared in a knee simulator to CoCr bearing on 3.5‐Mrad inserts. Methods: The knee design was the Bi‐Surface™ type with a 9‐year clinical history in Japan (JMM, Japan). A displacement‐controlled knee simulator was used with kinematics that included 20° flexion, ±5° rotation, and 6 mm anterior/posterior translation. Lubricant was alpha‐calf serum, test duration was 10 million cycles (10 Mc), and wear was measured by weight‐loss techniques. The wear zones were studied by laser interferometry, scanning electron microscopy, and Raman microprobe spectroscopy. Results: At 10 Mc the wear rates of the CoCr controls averaged 4.5 mm3/Mc. This was within 7% of the prior estimate at 5‐Mc duration and comparable to Bi‐Surface wear data from another laboratory. The CoCr condyles increased in roughness (Ra) from <50 nm to average Ra = 250 nm due to linear scratching. The ceramic condyles remained pristine throughout the wear study (Ra <7nm). With the YZr/7‐Mrad combination, the weight change had a positive slope over at 10 Mc, which meant that the actual polyethylene wear was unmeasurable. Microscopic examinations at 10 Mc showed that the zirconia surfaces were intact and there was no detectable change from tetragonal to monoclinic phase. Interpretation: Our laboratory knee wear simulation appeared very supportive of the 9‐year YZr/PE clinical results with Bi‐Surface total knee replacements in Japan. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2008
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (52)

Show source-provided references
1. Long‐term results of the total condylar knee arthroplasty10.1097/00003086-199301000-00015 ↗
2. 10.1097/00003086-200107000-0000910.1097/00003086-200107000-00009 ↗
3. 10.1080/1745367061004647910.1080/17453670610046479 ↗
4. 10.4028/www.scientific.net/KEM.240-242.80110.4028/www.scientific.net/KEM.240-242.801 ↗
5. 10.1097/01.blo.0000148576.70780.1310.1097/01.blo.0000148576.70780.13 ↗
6. Simulated knee wear with cobalt chromium and oxidized zirconium knee femoral components
7. 10.1002/jor.2022310.1002/jor.20223 ↗
8. 10.1097/00003086-200010000-0001310.1097/00003086-200010000-00013 ↗
9. 10.1002/(SICI)1097-4636(199702)34:2<149::AID-JBM2>3.0.CO;2-Q10.1002/(SICI)1097-4636(199702)34:2<149::AID-JBM2>3.0.CO;2-Q ↗
10. 10.1016/S0142-9612(98)00010-610.1016/S0142-9612(98)00010-6 ↗
11. 10.2106/00004623-200300004-0000910.2106/00004623-200300004-00009 ↗
12. 10.1053/j.sart.2006.09.01210.1053/j.sart.2006.09.012 ↗
13. 10.1302/0301-620X.83B7.1212210.1302/0301-620X.83B7.12122 ↗
14. 10.2106/00004623-200011000-0001710.2106/00004623-200011000-00017 ↗
15. 10.1002/jbm.a.3143810.1002/jbm.a.31438 ↗
16. 10.1097/01.blo.0000093003.90435.1f10.1097/01.blo.0000093003.90435.1f ↗
17. McKellopH LuB BenyaP.Friction lubrication and wear of cobalt‐chromium alumina and zirconia hip prostheses compared on a joint simulator. Paper presented at 38th Annual Meeting of the Orthopaedic Research Society Washington DC 1992.P402.
18. 10.1016/1350-4533(94)90042-610.1016/1350-4533(94)90042-6 ↗
19. 10.1016/0043-1648(94)90148-110.1016/0043-1648(94)90148-1 ↗
20. 10.1243/095441199153482510.1243/0954411991534825 ↗
21. 10.1302/0301-620X.85B4.1339710.1302/0301-620X.85B4.13397 ↗
22. WalterWL SkyrmeAD RichardS ChiaM GreenDD WalterWK ZicatB.Polyethylene wear rates with zirconia and cobalt chrome heads Paper Presented at 51st Annual Meeting of the Orthopaedic Research Society San Francisco CA 2004.P1194.
23. Green DD · 2003 · 133
24. 10.1016/j.arth.2004.06.01710.1016/j.arth.2004.06.017 ↗
25. 10.1243/095441197153472810.1243/0954411971534728 ↗
26. 10.1002/(SICI)1097-4636(1999)48:4<465::AID-JBM10>3.0.CO;2-Y10.1002/(SICI)1097-4636(1999)48:4<465::AID-JBM10>3.0.CO;2-Y ↗
27. ProzyrSt. Gobain. On February 4 2002 summarized their report of 162 fractures of Prozyr™ zirconia femoral heads made in tunnel furnace from January 1998 to September 1999. (1998–1992). Available atwww.prozyr.com.
28. AFSSPS(2001):Agence Française de Sécurité Sanitaire des Produits de Santé (France) distributed Advisory and Warning letter regarding their ongoing investigation into high fracture‐rates associated with Prozyr™ product made by St Gobain Advancees Desmarques (SGAD) using tunnel‐furnace sintering process (July 2001).
29. Food and Drug Adminstration (FDA): Recall of zirconia ceramic femoral heads for hip implants.2001. Available athttp://www.fda.gov/cdrh/recalls/zirconiahip.html.
30. 10.1243/EMED_JOUR_1981_010_036_0210.1243/EMED_JOUR_1981_010_036_02 ↗
31. ClarkeIC McGuirePJ HullDB OkudaR SarmientoA.Quantitative Laboratory Wear Studies Of Hip Prostheses. Paper Presented at 27th Annual Meeting of the Orthopaedic Research Society Las Vegas NV 1981.P185.
32. 10.1002/(SICI)1097-4636(1999)48:4<458::AID-JBM9>3.0.CO;2-B10.1002/(SICI)1097-4636(1999)48:4<458::AID-JBM9>3.0.CO;2-B ↗
33. Forces transmitted by joints in the human body
34. 10.1002/1097-4636(20010305)54:3<400::AID-JBM130>3.0.CO;2-Y10.1002/1097-4636(20010305)54:3<400::AID-JBM130>3.0.CO;2-Y ↗
35. 10.1002/jbm.1002710.1002/jbm.10027 ↗
36. 10.1002/jbm.b.2003310.1002/jbm.b.20033 ↗
37. ISO 14243–1:2002–03:Implants for surgery—Wear of total knee joint prostheses—Part 1: Loading and displacement parameters for wear‐testing machines with load control and corresponding environmental conditions for tests.
38. ISO 14243–2:2000–10:Implants for surgery—Wear of total knee joint prostheses—Part 2: Methods of measurement.
39. 10.1016/j.arth.2004.03.01910.1016/j.arth.2004.03.019 ↗
40. 10.1117/1.164754710.1117/1.1647547 ↗
41. 10.1007/s00216-004-2780-110.1007/s00216-004-2780-1 ↗
42. Determination of in‐depth probe response function using spectral perturbation methods10.1063/1.2134886 ↗
43. Katagiri G · 1988 · 537
44. 10.4028/www.scientific.net/KEM.240-242.77710.4028/www.scientific.net/KEM.240-242.777 ↗
45. 10.4028/www.scientific.net/KEM.309-311.121110.4028/www.scientific.net/KEM.309-311.1211 ↗
46. BrownS ClarkeIC.Triggering the phase transformation of zirconia ballsin vivoandin vitro. In: Proceedings of Trans Soc Biomat Pittsburgh PA April 26–29 2006. p103.
47. 10.1016/j.arth.2004.09.03510.1016/j.arth.2004.09.035 ↗
48. 10.1054/arth.2001.2054010.1054/arth.2001.20540 ↗
49. 10.1016/0142-9612(85)90007-910.1016/0142-9612(85)90007-9 ↗
50. WangA PolineniVK EssnerA SunDC StarkC DumbletonJH.Effect radiation dosage on the wear of stabilized UHMWPE evaluated by hip and knee joint simulators. Paper Presented at Annual Meeting Society for Biomaterials New Orleans LA 1997. p394.
51. GreenDD WilliamsPA DonaldsonTK ClarkeIC.Biolox‐Forte vs Biolox‐Delta under micro separation test mode in the USA. Paper Presented at 51st Annual Meeting of the Orthopaedic Research Society San Francisco CA 2004.P0239.
52. Possible triggers for phase transformation in zirconia hip balls