journal article·2007-07

Differential tissue‐on‐tissue lubrication by ophthalmic formulations

Anne E. Meyer, Robert E. Baier, Huagang Chen, Masood Chowhan

Publisher page

Abstract

Abstract Tissue‐on‐tissue friction testing was used to determine how instillation of hydrophilic polymer‐containing formulations between the “blinking” tissues would compare with lubrication by saline, alone, or an oil‐emulsion preparation. Best results were obtained for a formulation that contained active demulcents polyethylene glycol (PEG 400) and propylene glycol (PG), as well as a gellable polymer hydroxypropyl guar (HP‐Guar) in a borate‐buffered solution, in comparison with hydroxypropylcellulose‐containing and carboxymethylcellulose‐containing formulations. Superior performance of all the formulations was found for lubricating tissue‐on‐tissue couples, compared with metal‐oxide‐to‐metal oxide interfaces, or metal oxide‐to‐tissue interfaces. A reciprocating pin‐on‐disc type friction/wear test device articulated the intimal faces of preserved human umbilical cord vein segments under increasing loads during simulated continuous “eye‐blinking” with addition of increasing weights up to 60 g/cm2, simulating maximal eyelid force on the orbital globe. The tissue‐on‐tissue couples moved from liquid phase lubrication to boundary lubrication. After residual formulations were rinsed away with saline, persistence of low friction at the highest loads was indicative of formulation substantivity. Human umbilical cord vein segments were utilized in saline‐wetted tissue‐on‐tissue couples that showed variable starting coefficients of friction in the range 0.2–0.4, producing moderate tearing and disruption of the interfacial layers above the medial collagen zone. The best‐performing formulations instilled to the tissues pre‐wetted with saline apparently reacted separately with each tissue face to produce a lower final and persistent coefficient of friction of about 0.05. Scanning electron microscopy and light microscopy of these guar‐modified tissue specimens showed only a few superficial tissue disruptions, and some interphase swelling consistent with polymer uptake. The frictional values for lubricated couples having non‐tissue members were considerably higher than the coefficients of friction measured for the similarly lubricated tissue‐on‐tissue couples, emphasizing the requirement that appropriate simulations are critical to obtaining clinically predictive data. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Connective tissue disorders research · Botulinum Toxin and Related Neurological Disorders · Ocular Surface and Contact Lens

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (43)

Show source-provided references
1. Marquardt R · 1986 · 312
2. Human corneal and conjunctival epithelia express MUC1 mucin
3. 10.1038/nature0275010.1038/nature02750 ↗
4. 10.1016/0021-9797(86)90376-010.1016/0021-9797(86)90376-0 ↗
5. 10.1080/0021846060076667310.1080/00218460600766673 ↗
6. A comparison of the effect of Refresh Plus and Bion tears on dry eye symptoms and ocular surface health in myopic LASIK patients
7. 10.1007/978-1-4615-0717-8_3710.1007/978-1-4615-0717-8_37 ↗
8. 10.1089/jop.1994.10.1710.1089/jop.1994.10.17 ↗
9. 10.1016/j.ocl.2005.02.00410.1016/j.ocl.2005.02.004 ↗
10. 10.1016/S0021-9290(01)00058-610.1016/S0021-9290(01)00058-6 ↗
11. On the material and the tribology of alumina‐alumina couplings for hip joint prostheses10.1097/00003086-199209000-00005 ↗
12. 10.1243/095441100153526410.1243/0954411001535264 ↗
13. 10.1243/095441197153448510.1243/0954411971534485 ↗
14. Effect of tribochemical reaction on wear of silicon carbide for joint prostheses
15. 10.1016/j.wear.2004.01.00510.1016/j.wear.2004.01.005 ↗
16. 10.1115/1.140099610.1115/1.1400996 ↗
17. Silicone absorption of elastomeric closures—An accelerated study
18. 10.1097/00003226-200405000-0001510.1097/00003226-200405000-00015 ↗
19. 10.1089/1080768026021851510.1089/10807680260218515 ↗
20. 10.1097/00003226-199303000-0000410.1097/00003226-199303000-00004 ↗
21. 10.1089/10807680231737391410.1089/108076802317373914 ↗
22. Toxicity of natural tear substitutes in a fully defined culture model of human corneal epithelial cells
23. 10.1023/A:100560402844410.1023/A:1005604028444 ↗
24. 10.1002/ar.a.2005710.1002/ar.a.20057 ↗
25. 10.1067/mva.2002.12105310.1067/mva.2002.121053 ↗
26. Morphologic and biophysical assessment of long term human umbilical cord vein implants used as vascular conduits
27. Baier RE · 1978 · 76
28. Processed human umbilical cord veins for vascular reconstructive surgery
29. Blinking: Inner eyelid surface properties and contact lens wear
30. Surface properties of human corneal epithelium and endothelium
31. 10.1088/0031-9155/31/6/00510.1088/0031-9155/31/6/005 ↗
32. Surface interfacial rearrangement for energy minimization
33. 10.1021/la050988g10.1021/la050988g ↗
34. 10.1243/095441105X3422010.1243/095441105X34220 ↗
35. 10.1016/0002-9394(80)90058-610.1016/0002-9394(80)90058-6 ↗
36. Harrick NJ · 1967
37. 10.1021/ba-1964-0043.ch00110.1021/ba-1964-0043.ch001 ↗
38. 10.1080/002184670854458210.1080/0021846708544582 ↗
39. 10.1002/jbm.82011010710.1002/jbm.820110107 ↗
40. 10.1080/0271368049050378710.1080/02713680490503787 ↗
41. 10.1076/ceyr.28.1.55.2349510.1076/ceyr.28.1.55.23495 ↗
42. AsgharianB NolenL MeadowsD StoneR KostanskiK PeltonR KellerD.Novel gel‐forming ophthalmic polymer system for artificial tear solution. Presented at the ARVO Annual Meeting Ft. Lauderdale FL 2003. (Poster No. B311).
43. 10.1002/jbm.82018040410.1002/jbm.820180404 ↗