journal article·2009-08

Optimal sterilization method for the zirconia/alumina composites used for total hip replacements

Kwang Woo Nam, Jeong Joon Yoo, Kyung‐Hoi Koo, Kang Sup Yoon, Hee Joong Kim

Publisher page

Abstract

Abstract Zirconia/alumina composite ceramics have been recently developed for total hip arthroplasty because of their excellent mechanical properties and tribologic characteristics. All such materials used clinically must be easily sterilized, but no report has been issued concerning methods for sterilizing zirconia/alumina composite hip prostheses. Here, we show that 50 kGy of gamma irradiation effectively sterilizes both the surfaces and interiors of these materials. In addition, it was found that the commonly used ethylene oxide and 25‐kGy gamma irradiation sterilization methods inadequately sterilize deep inside the femoral head. Moreover, no changes in the chemical or mechanical properties of the composites were noted after exposure to 50‐kGy gamma irradiation. We suggest that 50‐kGy gamma irradiation is an optimal sterilization method for zirconia/alumina composite total hip replacements. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Advanced ceramic materials synthesis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (30)

Show source-provided references
1. 10.5435/00124635-199509000-0000110.5435/00124635-199509000-00001 ↗
2. The infected total hip arthroplasty
3. 10.1002/jbm.b.3045710.1002/jbm.b.30457 ↗
4. 10.1097/00003086-200010000-0001310.1097/00003086-200010000-00013 ↗
5. 10.2106/00004623-200300004-0000910.2106/00004623-200300004-00009 ↗
6. 10.1016/S0142-9612(98)00010-610.1016/S0142-9612(98)00010-6 ↗
7. 10.1111/j.1551-2916.2006.01108.x10.1111/j.1551-2916.2006.01108.x ↗
8. 10.1002/jbm.b.3068810.1002/jbm.b.30688 ↗
9. 10.1002/jbm.a.3143810.1002/jbm.a.31438 ↗
10. 10.1097/BLO.0b013e31811eb4c310.1097/BLO.0b013e31811eb4c3 ↗
11. Failures of yttria‐stabilised tetragonal zirconia: 52 retrieved ceramic femoral heads of total hip prostheses
12. Alumina‐on‐alumina total hip arthroplasty. A five‐year minimum follow‐up study10.2106/JBJS.D.01753 ↗
13. 10.1016/S0142-9612(98)00064-710.1016/S0142-9612(98)00064-7 ↗
14. 10.1002/jbm.82023010510.1002/jbm.820230105 ↗
15. 10.1016/j.clinbiomech.2007.04.00710.1016/j.clinbiomech.2007.04.007 ↗
16. Wear properties of alumina/zirconia composite ceramics for joint prostheses measured with an end‐face apparatus
17. Comparative study of pressure‐induced germination of Bacillus subtilis spores at low and high pressures10.1128/AEM.64.9.3220-3224.1998 ↗
18. 10.1146/annurev.mi.49.100195.00033310.1146/annurev.mi.49.100195.000333 ↗
19. 10.2187/bss.14.1410.2187/bss.14.14 ↗
20. Thermal inactivation characteristics of bacterial spores at ultrahigh temperatures10.1128/am.15.3.640-645.1967 ↗
21. 10.1046/j.1365-2672.2001.01394.x10.1046/j.1365-2672.2001.01394.x ↗
22. Influence of spore moisture content on the dry‐heat resistance of Bacillus subtilis var. niger10.1128/am.16.5.735-745.1968 ↗
23. 10.1128/AEM.62.10.3897-3900.199610.1128/AEM.62.10.3897-3900.1996 ↗
24. 10.1111/j.1462-2920.2004.00689.x10.1111/j.1462-2920.2004.00689.x ↗
25. 10.1016/j.jinf.2004.05.01210.1016/j.jinf.2004.05.012 ↗
26. 10.1128/CMR.6.4.32410.1128/CMR.6.4.324 ↗
27. Alumina‐debris‐induced osteolysis in contemporary alumina‐on‐alumina total hip arthroplasty. A case report10.2106/JBJS.G.00130 ↗
28. 10.2106/JBJS.F.0148910.2106/JBJS.F.01489 ↗
29. Fractures of ceramic bearings: History and present status10.1097/01.blo.0000096806.78689.50 ↗
30. 10.1007/s00402-006-0173-y10.1007/s00402-006-0173-y ↗