Evaluation of the effect of fluoride‐containing acetic acid on NiTi wires
Source abstract
Abstract
Abstract The possibility of the formation of hydrofluoric acid by the reaction of fluoride with acetic acid seems natural in the oral cavity. The effect of an acidic fluoride solution on NiTi wires was investigated by testing microhardness and color changes on wires. For aesthetic reasons, the color change on wires was also evaluated. Wires were immersed in four different test solutions for 1 or 3 days. As‐received wires were used as a reference. After immersion for 3 days, the microhardness of the tested wires increased 1.8% to 10.4% compared to that of their as‐received state. Wires immersed in a higher NaF concentration, lower pH solution with longer immersion yielded a more corroded surface than those of the counter cases. Wires showed a different color after immersion. However, after 3 days in solutions of pH 4, wires showed an appreciable color change regardless of the products. In test solutions, 3M wires showed the highest volumetric and percentage (0.59 for 0.05%; 1.19 for 0.2% solution) weight loss and G&H wires showed the least volumetric and percentage (0.43 for 0.05%; 1.05 for 0.2% solution) weight loss among tested wires. In pH 6 solutions, wires lost weight and were under the detection limit of the testing machine. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 72B: 102–108, 2005
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Orthodontics and Dentofacial Orthopedics · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. 10.1016/0002-9416(78)90184-710.1016/0002-9416(78)90184-7 ↗
2. Shape memory alloys and its medical applications
3. 10.3323/jcorr1991.40.83410.3323/jcorr1991.40.834 ↗
4. On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys
5. 10.14219/jada.archive.1989.017410.14219/jada.archive.1989.0174 ↗
6. Allergic reaction to nickel orthodontic wires: a case report
7. 10.1177/0022034580059010060110.1177/00220345800590100601 ↗
8. Corrosion of gold alloys and titanium in artificial saliva
9. 10.1002/(SICI)1097-4636(199612)32:4<583::AID-JBM11>3.0.CO;2-F10.1002/(SICI)1097-4636(199612)32:4<583::AID-JBM11>3.0.CO;2-F ↗
10. Surface corrosion of nitinol and stainless steel under clinical conditions
11. 10.1016/0889-5406(88)90080-710.1016/0889-5406(88)90080-7 ↗
12. 10.1093/ejo/22.3.31710.1093/ejo/22.3.317 ↗
13. 10.1016/0142-9612(85)90033-X10.1016/0142-9612(85)90033-X ↗
14. 10.1002/jab.77006040910.1002/jab.770060409 ↗
15. 10.1016/0300-5712(95)00033-X10.1016/0300-5712(95)00033-X ↗
16. The influence of fluoride concentration on the corrosion of titanium and titanium alloys
17. 10.1177/0022034599078009120110.1177/00220345990780091201 ↗
18. Hamilton IR · 1996 · 230
19. Bard JA · 1976 · 305
20. 10.1016/S0142-9612(00)00414-210.1016/S0142-9612(00)00414-2 ↗
21. 10.1007/s11661-002-0111-810.1007/s11661-002-0111-8 ↗
22. 10.1016/S0142-9612(02)00642-710.1016/S0142-9612(02)00642-7 ↗
23. 10.1128/mr.50.4.353-380.198610.1128/mr.50.4.353-380.1986 ↗
24. 10.1002/jbm.a.1045710.1002/jbm.a.10457 ↗
25. Decorative finishes on titanium10.1080/00202967.1967.11870018 ↗
26. 10.1002/(SICI)1097-4636(199603)30:3<393::AID-JBM14>3.0.CO;2-L10.1002/(SICI)1097-4636(199603)30:3<393::AID-JBM14>3.0.CO;2-L ↗
27. 10.1016/0021-9681(62)90101-710.1016/0021-9681(62)90101-7 ↗
28. 10.1159/00012923110.1159/000129231 ↗
29. 10.1002/jbm.82028021510.1002/jbm.820280215 ↗
30. 10.1902/jop.1996.67.12.126010.1902/jop.1996.67.12.1260 ↗