Abstract

Abstract Isothermal heat‐conduction microcalorimetry (IHCMC) allows measurement of extremely small rates of heat flow—on the order of 0.1 microwatt. This provides, for example, the ability to directly observe—and quantitate in a few days—rates of degradation as low as 1% per year at body temperature, in solid material samples of a few grams. Also, one method of IHCMC data analysis allows direct determination of the reaction‐rate constant at the temperature of interest, thereby avoiding possible errors due to rate mechanism changes with temperature, an issue that needs to be considered when the Arrhenius method is used. IHCMC can also be used to measure transient phenomena, such as heat of adsorption, and initial metabolic responses of cellular entities to biomaterials. The purposes of this review article are to (a) explain the basic principles, attractive features, limitations, and methods of IHCMC; (b) describe biomaterials applications to date—including studies of the stability of ultra‐high‐molecular‐weight polyethylene and implant‐grade calcium sulfate, setting reactions of dental adhesives, and macrophage response to biomaterial particles; (c) provide a discussion of issues and concerns that should be addressed in order to maximize the utility of IHCMC in biomaterials studies; and (d) suggest a number of possible future biomaterials applications for this technique. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 66B: 487–501, 2003
Source: crossref · Quality: baseline

Research context

OpenAlex topics: thermodynamics and calorimetric analyses · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (40)

Show source-provided references
1. 10.1002/9780470110430.ch110.1002/9780470110430.ch1 ↗
2. Toward a standard nomenclature for calorimetry
3. 10.1016/S1461-5347(99)00227-810.1016/S1461-5347(99)00227-8 ↗
4. 10.1023/A:101586531925010.1023/A:1015865319250 ↗
5. 10.1021/j100018a05110.1021/j100018a051 ↗
6. 10.1016/S0141-3910(99)00123-810.1016/S0141-3910(99)00123-8 ↗
7. Instrument selection for calorimetric drug stability studies
8. Evaluation of heat‐conduction microcalorimetry in pharmaceutical stability studies. I. Precision and accuracy for static experiments in glass vials
9. 10.1002/(SICI)1097-4636(199805)40:2<224::AID-JBM7>3.0.CO;2-N10.1002/(SICI)1097-4636(199805)40:2<224::AID-JBM7>3.0.CO;2-N ↗
10. Calorimetry Sciences Corporation (CSC) · 1995
11. DanielsAU CharleboisSJ GrisoniBG HaggardWO ParrJE.Predicted storage stability of antibiotic‐loaded calcium sulfate pellets by isothermal microcalorimetry. Trans 24th Ann Mtg Soc Biomater San Diego CA;1998. p348.
12. Isothermal microcalorimetry: A new tool for biomaterials research
13. CharleboisSJ.Stability and biocompatibility studies of implantable materials using isothermal microcalorimetry. Ph.D. dissertation Department of Mechanical Engineering The University of Memphis Memphis TN 1999.
14. DanielsAU CharleboisSJ.Stability and biocompatibility of materials by microcalorimetry. Trans 14th European Conference on Biomaterials;1998. Abs. No. 29.
15. DanielsAU CharleboisSJ TrieuHH HaggardWO ParrJE.Post‐sterilization dynamic chemical stability of UHMWPE by isothermal microcalorimetry. Trans 24th Ann Mtg Soc Biomater San Diego CA;1998. p27.
16. DanielsAU CharleboisSJ TrieuHH HaggardWO ParrJE.UHMWPE: Post‐sterilization stability by isothermal microcalorimetry. Trans 44th Ann Mtg Orthop Res Soc New Orleans LA;1998. pp101–117.
17. DanielsAU CharleboisSJ JohnsonRA HaggardWG JahanMS BuncickMC.Effect of sterilization method on long‐term stability of shelf‐stored and clinically‐retrieved UHMWPE. Trans 46th Ann Mtg Orthop Res Soc Orlando FL;2000. p2.
18. HardisonA JahanS BuncickM JaniS HolbrookJ HaggardW LewisG SmithR.Kinetic analysis of UHMWPE using isothermal microcalorimetry. Trans 27th Soc Biomater St. Paul MN;2001. p82.
19. HardisonA.Analysis of the thermo‐chemical stability of ultra high molecular weight polyethylene using isothermal microcalorimetry. MS thesis Department of Biomedical Engineering The University of Memphis Memphis TN;2001.
20. ThomasA SmithM.Study of various bone cements using isothermal microcalorimetry. Senior Year BSME project report Department of Mechanical Engineering The University of Memphis Memphis TN;1999.
21. A methodology for examining the plausibility of accelerated aging protocols for UHMWPE components
22. 10.1002/pol.1961.120501541110.1002/pol.1961.1205015411 ↗
23. 10.1016/S0040-6031(01)00726-210.1016/S0040-6031(01)00726-2 ↗
24. 10.1159/00017001510.1159/000170015 ↗
25. 10.1002/jbm.82029041210.1002/jbm.820290412 ↗
26. 10.1002/jbm.123010.1002/jbm.1230 ↗
27. 10.1002/(SICI)1097-4636(20000315)49:4<469::AID-JBM5>3.0.CO;2-A10.1002/(SICI)1097-4636(20000315)49:4<469::AID-JBM5>3.0.CO;2-A ↗
28. 10.1177/09603271870060030910.1177/096032718700600309 ↗
29. 10.1016/0378-5173(89)90127-010.1016/0378-5173(89)90127-0 ↗
30. 10.1016/0040-6031(90)80559-H10.1016/0040-6031(90)80559-H ↗
31. 10.1016/0304-4165(90)90138-M10.1016/0304-4165(90)90138-M ↗
32. 10.1139/v90-32110.1139/v90-321 ↗
33. 10.1023/A:101581622512710.1023/A:1015816225127 ↗
34. 10.1002/jcp.104150011410.1002/jcp.1041500114 ↗
35. 10.1016/S0040-6031(99)00418-910.1016/S0040-6031(99)00418-9 ↗
36. 10.1016/S0040-6031(98)00594-210.1016/S0040-6031(98)00594-2 ↗
37. LewisEA.Calorimetry Sciences Corporation American Fork UT. Private communication to A. U. (Dan) Daniels September1997.
38. 10.1016/S0142-9612(00)00195-210.1016/S0142-9612(00)00195-2 ↗
39. 10.1007/978-3-642-59762-610.1007/978-3-642-59762-6 ↗
40. 10.1071/CH975116910.1071/CH9751169 ↗