journal article·2007-01Open access

Influence of adhesive systems and flowable composite lining on bond strength of class II restorations submitted to thermal and mechanical stresses

Andrea Nóbrega Cavalcanti, Fabio Hiroyuki Ogata Mitsui, Gláucia Maria Bovi Ambrosano, Giselle Maria Marchi

Abstract

Abstract The purpose of this study was to evaluate the effect of adhesive systems and flowable composite lining on bond strength to gingival margins of Class II restorations after thermal/mechanical stresses. Proximal cavities were prepared in 90 bovine incisors. Teeth were assigned into nine groups (n = 10), according to the combination of bonding agent [Single Bond (SB), Optibond Solo Plus (OP), Prime & Bond NT (NT)] and layer (1 mm) of flowable composite Filtek Flow (FF) [absent, one layer, two layers]. Materials were applied according to manufacturers' instructions, and FF layers were photoactivated separately. Restorations were concluded with composite resin and were submitted to thermal (1000×, 5–55°C) and mechanical stresses (100,000×, 80 N). For microtensile evaluation, slabs from the gingival bonded interface were obtained, tested under tension, and their failure mode was observed by scanning electron microscopy. Bond strength data were analyzed using two‐way ANOVA/Tukey's test. No interaction was observed between adhesive systems and FF lining (p = 0.89). Also, no significant difference was found between bond strength values, whether or not FF layers were used (p = 0.33). However, bonding systems demonstrated significant differences (p = 0.01). SB and NT presented means higher than those observed with OP. Fracture modes varied considerably between experimental groups, and a greater frequency of cohesive failures was noted when FF layers were used. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2007
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Dental Erosion and Treatment · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (48)

Show source-provided references
1. 10.1111/j.1365-2842.2004.01272.x10.1111/j.1365-2842.2004.01272.x ↗
2. 10.1016/S0109-5641(97)80109-110.1016/S0109-5641(97)80109-1 ↗
3. Influence of thermal cycling on dentin bond strength of two‐step bonding systems
4. 10.1016/S0300-5712(01)00050-110.1016/S0300-5712(01)00050-1 ↗
5. 10.1111/j.1600-0722.2005.00213.x10.1111/j.1600-0722.2005.00213.x ↗
6. Long‐term bond strength of restorations subjected to thermo‐mechanical stresses over time
7. 10.1016/j.dental.2004.10.00110.1016/j.dental.2004.10.001 ↗
8. 10.1016/S0109-5641(01)00048-310.1016/S0109-5641(01)00048-3 ↗
9. 10.1002/jbm.b.1005210.1002/jbm.b.10052 ↗
10. 10.1177/0022034587066011060110.1177/00220345870660110601 ↗
11. 10.1016/j.dental.2004.10.00410.1016/j.dental.2004.10.004 ↗
12. Effect of thickness of flowable resins on marginal leakage in class II composite restorations
13. 10.1016/S0300-5712(01)00037-910.1016/S0300-5712(01)00037-9 ↗
14. 10.14219/jada.archive.1998.027410.14219/jada.archive.1998.0274 ↗
15. 10.1016/0022-3913(90)90291-J10.1016/0022-3913(90)90291-J ↗
16. 10.1177/0022034590069006030110.1177/00220345900690060301 ↗
17. 10.1016/S0300-5712(96)00063-210.1016/S0300-5712(96)00063-2 ↗
18. 10.1111/j.1600-0722.2004.00185.x10.1111/j.1600-0722.2004.00185.x ↗
19. 10.14219/jada.archive.2003.025810.14219/jada.archive.2003.0258 ↗
20. The effect of flowable resin composites as gingival increments on the microleakage of posterior resin composites
21. Influence of flowable composite lining thickness on Class II composite restorations
22. 10.1016/j.dental.2003.10.01510.1016/j.dental.2003.10.015 ↗
23. 10.1016/S0300-5712(02)00122-710.1016/S0300-5712(02)00122-7 ↗
24. 10.1016/S0109-5641(99)00022-610.1016/S0109-5641(99)00022-6 ↗
25. Flowable resin composites as “filled adhesives”: Literature review and clinical recommendations
26. Shear bond strength of four filled dentin bonding systems
27. 10.1016/S0109-5641(01)00040-910.1016/S0109-5641(01)00040-9 ↗
28. 10.1177/0022034500079003050110.1177/00220345000790030501 ↗
29. Flow, strength, stiffness and radiopacity of flowable resin composites
30. Nanoleakage types and potential implications: Evidence from unfilled and filled adhesives with the same resin composition
31. 10.1016/S0109-5641(00)00081-610.1016/S0109-5641(00)00081-6 ↗
32. Tensile bond strength of filled and unfilled adhesives to dentin
33. Microtensile bond strength of several adhesive systems to different dentin depths
34. 10.1016/j.dental.2004.07.00510.1016/j.dental.2004.07.005 ↗
35. Thermal and mechanical load cycling on microleakage and shear bond strength to dentin
36. Effect of thermal and mechanical load cycling on microtensile bond strength of a total‐etch adhesive system
37. 10.1002/jbm.a.3027410.1002/jbm.a.30274 ↗
38. 10.1016/j.dental.2004.01.00310.1016/j.dental.2004.01.003 ↗
39. 10.1016/j.dental.2003.08.00110.1016/j.dental.2003.08.001 ↗
40. Influence of load cycling on marginal microleakage with two self‐etching and two one‐bottle dentin adhesive systems in dentin
41. 10.1016/S0109-5641(00)00089-010.1016/S0109-5641(00)00089-0 ↗
42. Effect of thermal and mechanical load cycling on nanoleakage of Class II restorations
43. 10.1016/S0109-5641(00)00007-510.1016/S0109-5641(00)00007-5 ↗
44. Comparison of microtensile bond strength to enamel and dentin of human, bovine, and porcine teeth
45. Microleakage of new dentin bonding systems using human and bovine teeth
46. 10.1177/0022034583062010150110.1177/00220345830620101501 ↗
47. 10.1016/0109-5641(95)80055-710.1016/0109-5641(95)80055-7 ↗
48. Fractographical analysis of resin–dentin bonds