Biocompatibility and biomechanical analysis of elastic TPU threads as new suture material

Ruben R. M. Vogels, Andreas Lambertz, Philipp Schuster, Stefan Jockenhoevel, Nicole D. Bouvy, Catherine Disselhorst‐Klug, Ulf P. Neumann, Uwe Klinge, Christian D. Klink

Publisher page

Abstract

Abstract High suture tension is one of the causes for many wound‐healing problems. Constriction of tissue within the suture loops of nonelastic sutures can lead to cutting of the suture through tissues and necrosis of the tissue within these loops. The use of elastic materials in new suture types could give the material the ability to adapt tension to the tissue requirements and subsequently lead to more vital tissue within its loops. We evaluated the foreign body host response, as indicator of biocompatibility, to a new thermoplastic poly(carbonate) urethane (TPU) synthetic suture material in a rat model compared with standard nonelastic polypropylene (PP) sutures. Tissue samples were collected at 7 and 21 days, and host response was evaluated. Subsequently, suture tension curves of the new elastic sutures for the first 30 min after knotting were recorded in a pig model. The new TPU sutures showed an improved foreign body response when compared with that of PP, with a reduction in the amount of macrophages surrounding the material. Tension experiments showed a superior tension curve for TPU sutures, with a major reduction in peak suture tension when compared with that of standard PP sutures, while still retaining adequate tension after 30 min. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 99–106, 2017.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Surgical Sutures and Adhesives · Shoulder Injury and Treatment · Reconstructive Surgery and Microvascular Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of General, Visceral and Transplantation Surgery RWTH Aachen University Aachen Germany

Department of General Surgery Maastricht University Medical Centre Maastricht The Netherlands

Institut fuer Textiltechnik at RWTH Aachen University Aachen Germany

Department of Rehabilitation & Prevention Engineering, Institute of Applied Medical Engineering RWTH Aachen University Aachen Germany

Funding

Bundesministerium für Bildung und Forschung - BMBF, Berlin, Germany

References (31)

Show source-provided references
1. 10.1007/s00423-012-1019-410.1007/s00423-012-1019-4 ↗
2. 10.1016/j.jss.2012.09.00910.1016/j.jss.2012.09.009 ↗
3. 10.1080/11024159875000438210.1080/110241598750004382 ↗
4. 10.1016/S1015-9584(08)60069-X10.1016/S1015-9584(08)60069-X ↗
5. 10.1016/j.amjsurg.2008.10.01810.1016/j.amjsurg.2008.10.018 ↗
6. 10.1186/1471-2482-11-3610.1186/1471-2482-11-36 ↗
7. 10.1177/08853282990140010410.1177/088532829901400104 ↗
8. 10.1002/jbm.a.3425510.1002/jbm.a.34255 ↗
9. Planck H. · 1993
10. 10.1007/978-3-540-93936-810.1007/978-3-540-93936-8 ↗
11. 10.1007/978-3-662-06077-310.1007/978-3-662-06077-3 ↗
12. 10.1016/j.actbio.2005.02.00710.1016/j.actbio.2005.02.007 ↗
13. 10.1002/jbm.a.3406610.1002/jbm.a.34066 ↗
14. 10.1159/00032225010.1159/000322250 ↗
15. 10.1679/aohc1950.41.26710.1679/aohc1950.41.267 ↗
16. 10.1159/00007338910.1159/000073389 ↗
17. 10.1007/s00281-010-0237-510.1007/s00281-010-0237-5 ↗
18. 10.3109/08941939.2010.54890410.3109/08941939.2010.548904 ↗
19. 10.1007/s10029010001910.1007/s100290100019 ↗
20. 10.1002/jbm.b.3024710.1002/jbm.b.30247 ↗
21. 10.1016/j.actbio.2012.03.02910.1016/j.actbio.2012.03.029 ↗
22. 10.1046/j.1525-1594.2000.06338.x10.1046/j.1525-1594.2000.06338.x ↗
23. 10.1002/jbm.b.3322210.1002/jbm.b.33222 ↗
24. 10.1007/s00423-011-0780-010.1007/s00423-011-0780-0 ↗
25. 10.1016/S0142-9612(02)00070-410.1016/S0142-9612(02)00070-4 ↗
26. 10.1007/s00281-011-0244-110.1007/s00281-011-0244-1 ↗
27. 10.1016/j.smim.2007.11.00410.1016/j.smim.2007.11.004 ↗
28. 10.1007/s00423000019610.1007/s004230000196 ↗
29. 10.1016/j.biomaterials.2008.04.02310.1016/j.biomaterials.2008.04.023 ↗
30. 10.1016/S0039-6109(05)70571-510.1016/S0039-6109(05)70571-5 ↗
31. 10.1046/j.1365-2168.2002.02258.x10.1046/j.1365-2168.2002.02258.x ↗