journal article·2010-05

Potential for adhesive wear in friction couples of UHMWPE running against oxidized zirconium, titanium nitride coatings, and cobalt‐chromium alloys

Mathias C. Galetz, Sabine H. Seiferth, Benjamin Theile, Uwe Glatzel

Publisher page

Abstract

Abstract The classical wear mechanisms abrasion, fatigue, and adhesion are the most frequent causes of surface changes of ultra high molecular weight polyethylene (UHMWPE) in artificial joints. The counterpart material has a strong influence on the wear and friction behavior of artificial joints due to its abrasive properties and adhesive interaction with UHMWPE. The formation of a transfer layer on the counterpart in UHMWPE bearing systems is often described as being a clear indication of strong adhesive forces. The influence of using a cobalt‐chromium‐molybdenum (CoCrMo) alloy, a titanium nitride plasma coating or an oxidized zirconium alloy on adhesive wear was studied. The surface free energy and the bonding forces of these counterpart materials to UHMWPE were investigated. Catalytic effects on the degradation behavior of polyethylene, the micro friction behavior, and the build‐up and constitution of a transfer layer deposited under loads, and relative velocities that are relevant in knee joints were analyzed. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2010
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Tribology and Wear Analysis · Metal and Thin Film Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (30)

Show source-provided references
1. 10.1016/j.biomaterials.2007.07.04010.1016/j.biomaterials.2007.07.040 ↗
2. Brown KJ · 1975
3. 10.1016/j.wear.2005.01.05010.1016/j.wear.2005.01.050 ↗
4. Abrasion resistance of oxidized zirconium in comparison with CoCrMo and titaniumnitrid coatings for artificial knee joints
5. Uetz H · 1985
6. Reibung von Elastomeren
7. Furukama J · 2003
8. 10.1016/S0021-9290(00)00181-010.1016/S0021-9290(00)00181-0 ↗
9. 10.1243/EMED_JOUR_1981_010_037_0210.1243/EMED_JOUR_1981_010_037_02 ↗
10. 10.1016/S0043-1648(98)00294-410.1016/S0043-1648(98)00294-4 ↗
11. 10.1016/0043-1648(91)90259-W10.1016/0043-1648(91)90259-W ↗
12. 10.1016/j.matchemphys.2003.10.02110.1016/j.matchemphys.2003.10.021 ↗
13. Wear testing of materials and surfaces for total knee replacement
14. 10.1111/j.1600-0536.1993.tb03318.x10.1111/j.1600-0536.1993.tb03318.x ↗
15. Titanium nitride ceramic film against polyethylene. A 48 million cycle wear test
16. 10.1243/095441198153408810.1243/0954411981534088 ↗
17. Brezesinski G · 1993
18. 10.1002/app.1969.07013081510.1002/app.1969.070130815 ↗
19. van Oss CJ · 1994
20. 10.1021/ie50320a02410.1021/ie50320a024 ↗
21. Paul JP · 1976
22. 10.1243/PIME_PROC_1996_210_407_0210.1243/PIME_PROC_1996_210_407_02 ↗
23. 10.1243/PIME_PROC_1996_210_408_0210.1243/PIME_PROC_1996_210_408_02 ↗
24. 10.1007/s11249-005-7787-z10.1007/s11249-005-7787-z ↗
25. LeichtleUN RuppF KraftC Geis‐GerstorferJ WülkeN. Material‐ und Verschleiβeigenschaften von Oxinium einem neuen Werkstoff im Bereich Knietotalendoprothetik. Presented at the Deutscher Kongress für Orthopädie und Unfallchirurgie Berlin October 24‐27 2007.
26. 10.1002/apmc.1972.05021011410.1002/apmc.1972.050210114 ↗
27. Application of a sealed tube test to the study of degraded insulation resulting from thermal aging of cables with PVC jacket
28. Scratches on condyle in normal functioning total knee arthroplasty
29. Brandenburg A · 2001
30. Kragelski IV · 1983