journal article·2005-08Open access

Evaluation of load testing of postendodontic restorations in vitro: Linear compressive loading, gradual cycling loading and chewing simulation

Michael Naumann, Guido Sterzenbach, Peter Pröschel

Abstract

Abstract This study introduces a modified dynamic testing mode with gradual load increase and examines whether this could be an alternative to customary methods of static loading or chewing simulation. Seventy‐two extracted human maxillary root‐canal–treated central incisors were randomly divided into six groups with 12 teeth each. Three groups were restored with titanium posts cemented with chemically curing resin cement. The other three groups were restored with glass‐fiber posts cemented with dual‐curing composite cement. All teeth were capped with full ceramic crowns. Both kinds of restoration were tested by linear compressive (static) loading, a modified gradual (cycling) dynamic loading, and by chewing simulation followed by static loading until failure occurred. The maximum load capacity was recorded. Statistical comparison showed that maximum load capacities of the same post material obtained from gradual dynamic loading did not differ significantly from that of linear compressive loading or of chewing simulation. In contrast, comparisons of different post materials under static loading resulted in significantly different load capacities. Dynamic testing with gradual load increase can be considered an economic alternative for chewing simulation, because it provides equivalent results. Both procedures, however, imply different conclusions than static loading with respect to post materials. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2005
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (24)

Show source-provided references
1. 10.1177/0022034583062001080110.1177/00220345830620010801 ↗
2. In‐vitro test results of the evaluation of dental restoration systems. Correlation with in‐vivo results
3. 10.1046/j.1365-2842.2001.00720.x10.1046/j.1365-2842.2001.00720.x ↗
4. 10.1016/0022-3913(93)90030-R10.1016/0022-3913(93)90030-R ↗
5. 10.1067/mpr.2002.12384810.1067/mpr.2002.123848 ↗
6. 10.1016/S0022-3913(99)70103-410.1016/S0022-3913(99)70103-4 ↗
7. An in vitro test procedure for evaluating dental restoration systems. 1. A computer‐controlled mastication simulator
8. 10.1046/j.1365-2842.1999.00416.x10.1046/j.1365-2842.1999.00416.x ↗
9. Survival rate and fracture strength of endodontically treated maxillary incisors with moderate defects restored with different post‐and‐core systems: an in vitro study
10. 10.1016/S0300-5712(01)00038-010.1016/S0300-5712(01)00038-0 ↗
11. 10.1067/mpr.2002.12384910.1067/mpr.2002.123849 ↗
12. Intermittent loading of teeth with tapered, individually cast or prefabricated, parallel‐sided posts
13. Intermittent loading of teeth restored using prefabricated carbon fiber posts
14. Intermittent loading of teeth restored using quartz fiber, carbon‐quartz fiber, and zirconium dioxide ceramic root canal posts
15. Adaptation of adhesive posts and cores to dentin after fatigue testing
16. Load fatigue of teeth restored with cast posts and cores and complete crowns
17. Marginal ridge strength of teeth with tunnel preparations
18. 10.1016/0022-3913(92)90073-J10.1016/0022-3913(92)90073-J ↗
19. 10.1016/0030-4220(72)90351-910.1016/0030-4220(72)90351-9 ↗
20. 10.1016/S0099-2399(06)80483-810.1016/S0099-2399(06)80483-8 ↗
21. 10.1016/0022-3913(90)90070-S10.1016/0022-3913(90)90070-S ↗
22. Effect of thermocycling on the retention of glass‐fiber root canal posts
23. 10.1016/S0003-9969(96)00106-910.1016/S0003-9969(96)00106-9 ↗
24. Effect of tooth preparation height and diameter on the resistance of complete crowns to fatigue loading