journal article·2020-07Open access

Evidence of structural cavities in 3D printed acetabular cups for total hip arthroplasty

Harry Hothi, Lorenzo Dall'Ava, Johann Henckel, Anna Di Laura, Francesco Iacoviello, Paul Shearing, Alister Hart

Abstract

Abstract The use of three‐dimensional (3D) printing to manufacture off‐the‐shelf titanium acetabular cups for hip arthroplasty has increased; however, the impact of this manufacturing technology is yet not fully understood. Although several studies have described the presence of structural cavities in 3D printed parts, there has been no analysis of full postproduction acetabular components. The aim of this study was to investigate the effect of 3D printing on the material structure of acetabular implants, first comparing different designs of 3D printed cups, second comparing 3D printed with conventionally manufactured cups. Two of the 3D printed cups were produced using electron beam melting (EBM), one using laser rapid manufacturing (LRM). The investigation was performed using X‐ray microcomputed tomography, imaging both the entire cups and samples sectioned from different regions of each cup. All 3D printed cups showed evidence of structural cavities; these were uniformly distributed in the volume of the samples and exhibited a prevalent spherical shape. The LRM‐manufactured cup had significantly higher cavity density (p = .0286), with a median of 21 cavities/mm3 compared to 3.5 cavities/mm3 for EBM cups. However, the cavity size was similar, with a median of 20 μm (p = .7385). The conventional cups showed a complete absence of distinguishable cavities. The presence of cavities is a known limitation of the 3D printing technology; however, it is noteworthy that we found them in orthopedic implants used in patients. Although this may impact their mechanical properties, to date, 3D printed cups have not been reported to encounter such failures.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Advanced X-ray and CT Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital Stanmore UK

Electrochemical Innovation Lab, Department of Chemical Engineering University College London London UK

References (29)

Show source-provided references
1. 10.2106/JBJS.H.0015510.2106/JBJS.H.00155 ↗
2. 10.1177/112070001881299210.1177/1120700018812992 ↗
3. 10.1016/j.pmatsci.2017.10.00110.1016/j.pmatsci.2017.10.001 ↗
4. Delta T. T.(2012). Acetabular system (K112898).
5. 10.1089/3dp.2015.003410.1089/3dp.2015.0034 ↗
6. 10.1089/3dp.2016.001210.1089/3dp.2016.0012 ↗
7. 10.1089/3dp.2018.006010.1089/3dp.2018.0060 ↗
8. 10.1007/978-94-007-2592-8_310.1007/978-94-007-2592-8_3 ↗
9. 10.1016/j.matdes.2015.07.14710.1016/j.matdes.2015.07.147 ↗
10. 10.1016/j.addma.2014.08.00210.1016/j.addma.2014.08.002 ↗
11. 10.1007/s11665-017-2796-210.1007/s11665-017-2796-2 ↗
12. 10.1016/j.matdes.2016.05.07010.1016/j.matdes.2016.05.070 ↗
13. 10.1016/j.actamat.2016.02.01410.1016/j.actamat.2016.02.014 ↗
14. 10.1016/j.cirp.2011.05.00610.1016/j.cirp.2011.05.006 ↗
15. 10.1016/j.ijfatigue.2012.11.01110.1016/j.ijfatigue.2012.11.011 ↗
16. Mctighe T. · 2015 · 1
17. Mpact® 3D Metal™ Implants and Augments 3D Metal™ (K171966).2018.
18. 10.1302/0301-620X.100B4.BJJ-2017-0662.R210.1302/0301-620X.100B4.BJJ-2017-0662.R2 ↗
19. 10.1080/10667857.2017.138905210.1080/10667857.2017.1389052 ↗
20. Novel highly porous metal technology in artificial hip and knee replacement: Processing methodologies and clinical applications
21. National Joint Registry for England Wales Northern Ireland and the Isle of Man. (2019).15th annual report[Internet]. 2018. Retrieved fromhttp://www.njrcentre.org.uk
22. 10.1302/0301-620X.97B8.3517010.1302/0301-620X.97B8.35170 ↗
23. 10.1186/s12891-015-0822-910.1186/s12891-015-0822-9 ↗
24. 10.1557/mrs.2015.110.1557/mrs.2015.1 ↗
25. 10.1080/09506608.2015.111664910.1080/09506608.2015.1116649 ↗
26. 10.1016/S0021-9290(99)00121-910.1016/S0021-9290(99)00121-9 ↗
27. 10.1007/s00264-014-2509-510.1007/s00264-014-2509-5 ↗
28. Trident® II Tritanium® Acetabular Shell (K161569).2016.
29. 10.1016/j.cirp.2016.04.05410.1016/j.cirp.2016.04.054 ↗