Rapid prototyped sutureless anastomosis device from self‐curing silk bio‐ink
Source abstract
Abstract
Abstract Sutureless anastomosis devices are designed to reduce surgical time and difficulty, which may lead to quicker and less invasive cardiovascular anastomosis. The implant uses a barb‐and‐seat compression fitting composed of one male and two female components. The implant body is resorbable and capable of eluting heparin. Custom robotic deposition equipment was designed to fabricate the implants from a self‐curing silk solution. Curing did not require deleterious processing steps but devices demonstrated high crush resistance, retention strength, and leak resistance. Radial crush resistance is in the range of metal vascular implants. Insertion force and retention strength of the anastomosis was dependent on fit sizing of the male and female components and subsequent vessel wall compression. Anastomotic burst strength was dependent on the amount of vessel wall compression, and capable of maintaining higher than physiological pressures. In initial screening using a porcine implant, the devices remained intact for 28 days (the length of study). Histological sections revealed cellular infiltration within the laminar structure of the male component, as well as at the interface between the male and female components. Initial degradation and absorption of the implant wall were observed. The speed per anastomosis using this new device was much faster than current systems, providing significant clinical improvement. © 2014 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 103B: 1333–1343, 2015.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Silk-based biomaterials and applications · Electrospun Nanofibers in Biomedical Applications · Reconstructive Surgery and Microvascular Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Biomedical Engineering Science and Technology Center Tufts University Medford Massachusetts 02155
Division of Plastic and Reconstructive Surgery Beth Israel Deaconess Medical Center Harvard Medical School Boston Massachusetts 02215
Department of Infectious Disease and Global Health Cummings School of Veterinary Medicine, Tufts Clinical and Translational Science Institute, Tufts University Grafton MA 01536
Funding
NIH
References (41)
Show source-provided references
1. 10.1007/s00402-009-1021-710.1007/s00402-009-1021-7 ↗
2. Injury in vascular surgery–the intimal hyperplastic response
3. 10.1097/00006534-199907000-0001410.1097/00006534-199907000-00014 ↗
4. 10.1097/01.prs.0000260598.24376.e110.1097/01.prs.0000260598.24376.e1 ↗
5. 10.1002/micr.2093010.1002/micr.20930 ↗
6. Interrupted nitinol U‐Clips versus standard running suture for the central arterial T‐graft anastomosis: A prospective randomized study
7. 10.1016/S0022-5347(05)00143-610.1016/S0022-5347(05)00143-6 ↗
8. 10.1055/s-0033-134411910.1055/s-0033-1344119 ↗
9. 10.1007/s00246-012-0439-910.1007/s00246-012-0439-9 ↗
10. 10.1002/jbm.b.3096610.1002/jbm.b.30966 ↗
11. 10.1002/jbm.b.3313710.1002/jbm.b.33137 ↗
12. 10.1002/micr.2076410.1002/micr.20764 ↗
13. 10.1016/j.biomaterials.2007.08.00810.1016/j.biomaterials.2007.08.008 ↗
14. 10.1021/bm900993n10.1021/bm900993n ↗
15. 10.1002/mabi.20090029410.1002/mabi.200900294 ↗
16. 10.1161/CIRCINTERVENTIONS.109.85917310.1161/CIRCINTERVENTIONS.109.859173 ↗
17. 10.1007/BF0059961710.1007/BF00599617 ↗
18. The changes in intramuscular pressure and femoral vein flow with continuous passive motion, pneumatic compressive stockings, and leg manipulations
19. 10.1002/adhm.20120009710.1002/adhm.201200097 ↗
20. 10.1002/jbm.b.3314210.1002/jbm.b.33142 ↗
21. 10.1016/S0142-9612(02)00326-510.1016/S0142-9612(02)00326-5 ↗
22. 10.1016/S0142-9612(02)00353-810.1016/S0142-9612(02)00353-8 ↗
23. 10.1002/app.1339310.1002/app.13393 ↗
24. 10.1016/j.biomaterials.2008.05.00210.1016/j.biomaterials.2008.05.002 ↗
25. 10.1016/j.biomaterials.2004.02.04710.1016/j.biomaterials.2004.02.047 ↗
26. 10.1006/jsre.1994.105810.1006/jsre.1994.1058 ↗
27. 10.1002/jbm.b.3306910.1002/jbm.b.33069 ↗
28. 10.1016/j.jvs.2011.07.08210.1016/j.jvs.2011.07.082 ↗
29. 10.1002/micr.2081310.1002/micr.20813 ↗
30. Venous coupler for free‐flap anastomosis: Outcomes of 1,000 cases
31. 10.1002/bjs.506310.1002/bjs.5063 ↗
32. 10.1055/s-2008-106492610.1055/s-2008-1064926 ↗
33. 10.1002/micr.2028610.1002/micr.20286 ↗
34. 10.1016/j.athoracsur.2006.01.09910.1016/j.athoracsur.2006.01.099 ↗
35. 10.1161/CIRCINTERVENTIONS.108.79792810.1161/CIRCINTERVENTIONS.108.797928 ↗
36. 10.1016/S0140-6736(12)60324-910.1016/S0140-6736(12)60324-9 ↗
37. 10.2147/VHRM.S2255110.2147/VHRM.S22551 ↗
38. 10.1161/01.CIR.94.7.169010.1161/01.CIR.94.7.1690 ↗
39. 10.2298/VSP110404002V10.2298/VSP110404002V ↗
40. 10.1111/j.1525-1594.2007.00391.x10.1111/j.1525-1594.2007.00391.x ↗
41. 10.1002/ccd.2040010.1002/ccd.20400 ↗