journal article·2014-06

Microstructural effects on the wear behavior of a biomedical as‐cast Co‐27Cr‐5Mo‐0.25C alloy exposed to pulsed laser melting

J. L. Acevedo‐Dávila, H. F. López, F. Cepeda‐Rodríguez, M. Rodriguez‐Reyes, F. García‐Vazquez, H. M. Hernández‐Garcia

Publisher page

Abstract

Abstract In this work, the effect of pulsed laser melting on the exhibited microstructure and properties of a cast Co‐27Cr‐5Mo‐0.25C alloy was investigated. In particular, properties such as surface hardness and wear behavior of the laser modified microstructure were determined as a function of the implemented laser melting parameters. It was found that laser melting promotes significant grain refinement while preventing the precipitation of coarse carbide phases. Apparently, a refined dendritic grain structure develops which is surrounded by a fine carbide distribution in the interdendritic regions. Moreover, the high‐temperature face centered cubic (FCC) phase remains untransformed at room temperature. Hardness measurements and wear testing using a Pin‐On‐Disk tribological machine indicate that the modified laser surfaces exhibit both, high wear resistance and high microhardness when compared with the untreated as‐cast Co‐27Cr‐5Mo‐0.25C alloy. In particular, it was found that the laser modified surfaces exhibit improved wear and friction properties comparable to the ones found in Co‐Cr‐Mo alloys with a predominantly hexagonal closest packed (HCP) matrix. However, surface defects associated with the laser process can be detrimental for the improved wear performance and they should be considered in identifying the proper laser parameters in alloy melting. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 2008–2016, 2014.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Additive Manufacturing Materials and Processes · High Entropy Alloys Studies · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Corporación Mexicana de Investigación en Materiales Calle Ciencia y Tecnología No. 790 Col. Saltillo 400 Apdo. Postal No. 491. Saltillo C.P. 25290 Coahuila México

Department of Materials Science and Engineering University of Wisconsin‐Milwaukee EMS Building 3200 N. Cramer Street Milwaukee Wisconsin 53211

Facultad de Ingeniería Mecánica y Eléctrica Universidad Autónoma de Nuevo León Av. Universidad S/N San Nicolás de los Garza C.P. 66450 Nuevo León México

Departamento de Metal‐Mecanica Instituto Tecnologico de Saltillo Venustiano Carranza 2400, Col. Tecnológico, Saltillo C.P. 25280 Coahuila México

References (42)

Show source-provided references
1. PoggieRA AfflittoR St JohnK.The wear performance of precision Co‐Cr‐Mo alloy metal‐on‐metal hip bearings. In: 12th Annual International Symposium for Technology in Arthoplasty. New York:1999. p1–2.
2. 10.1097/00003086-199608001-0000410.1097/00003086-199608001-00004 ↗
3. Salinas‐RodriguezA.The role of the fcc‐hcp phase transformation during the plastic deformation of Co‐Cr‐Mo‐C alloys for biomedical applications. In: Disegi JA Kennedy RL Pilliar R editors. Cobalt‐base Alloys for Biomedical Applications ASTM STP 1365 American Society for Testing and Materials 1999. p108–121.10.1520/STP14267S ↗
4. Phase characterization in as‐cast F‐75 Co‐Cr‐Mo‐C alloy
5. 10.1016/S0261-3069(96)00038-610.1016/S0261-3069(96)00038-6 ↗
6. 10.1361/10599490177034515010.1361/105994901770345150 ↗
7. Efectos microestructurales sobre la resistencia a la fatiga en una aleacion Co Cr‐Mo de bajo carbon
8. 10.1243/09544119JEIM11010.1243/09544119JEIM110 ↗
9. Petrovic V · 2012
10. 10.1002/1097-4636(20010315)54:4<591::AID-JBM160>3.0.CO;2-A10.1002/1097-4636(20010315)54:4<591::AID-JBM160>3.0.CO;2-A ↗
11. A histopathologic study of late aseptic loosening of cemented total hip prostheses10.1097/00003086-199202000-00025 ↗
12. 10.1007/BF0045469410.1007/BF00454694 ↗
13. Cobalt alloy metal debris in periarticular tissues from total hip revisión arthroplasties: Metal contents and associated histologic findings10.1097/00003086-199203000-00011 ↗
14. 10.1007/BF0045045710.1007/BF00450457 ↗
15. 10.1016/j.wear.2004.03.00810.1016/j.wear.2004.03.008 ↗
16. 10.1016/S0924-0136(03)00077-310.1016/S0924-0136(03)00077-3 ↗
17. 10.1002/jbm.a.3039210.1002/jbm.a.30392 ↗
18. 10.1179/02670839910150569910.1179/026708399101505699 ↗
19. Lopez HF · 2000 · 307
20. 10.1007/s11661-999-0267-610.1007/s11661-999-0267-6 ↗
21. 10.1007/s10856-005-2536-210.1007/s10856-005-2536-2 ↗
22. 10.1016/S0043-1648(03)00526-X10.1016/S0043-1648(03)00526-X ↗
23. 10.1016/0257-8972(95)02484-010.1016/0257-8972(95)02484-0 ↗
24. 10.1016/S0257-8972(02)00165-210.1016/S0257-8972(02)00165-2 ↗
25. 10.1016/S0257-8972(99)00015-810.1016/S0257-8972(99)00015-8 ↗
26. 10.1016/j.wear.2005.01.03610.1016/j.wear.2005.01.036 ↗
27. 10.1016/j.wear.2008.12.01510.1016/j.wear.2008.12.015 ↗
28. 10.1016/j.wear.2005.04.01210.1016/j.wear.2005.04.012 ↗
29. 2001
30. 10.1016/B978-075066079-2/50019-210.1016/B978-075066079-2/50019-2 ↗
31. 10.1016/0017-9310(93)80047-X10.1016/0017-9310(93)80047-X ↗
32. 10.1007/BF0054415110.1007/BF00544151 ↗
33. Ready JF · 2001
34. 10.1007/BF0267259210.1007/BF02672592 ↗
35. 10.1016/0043-1648(93)90259-O10.1016/0043-1648(93)90259-O ↗
36. Tribological behaviour of Ti‐based alloys in simulated body fluid solution at fretting contacts
37. 10.1016/j.diamond.2003.10.05310.1016/j.diamond.2003.10.053 ↗
38. 10.2320/matertrans.46.158810.2320/matertrans.46.1588 ↗
39. 10.2320/matertrans.46.157810.2320/matertrans.46.1578 ↗
40. 10.1007/s11661-999-0052-610.1007/s11661-999-0052-6 ↗
41. 10.1179/02670839910150569910.1179/026708399101505699 ↗
42. Martensitic transformation in a cast Co‐Cr‐Mo‐C alloy10.1007/s11661-007-9370-8 ↗