Tissue adhesiveness and host response of in situ photopolymerizable interpenetrating networks containing methylprednisolone acetate
Source abstract
Abstract
Abstract Interpenetrating networks (IPNs) of varying formulations were investigated as candidates for an in situ photopolymerizable drug delivery matrix containing poly(ethylene glycol) diacrylate and gelatin. The anti‐inflammatory agent methylprednisolone acetate was loaded into the IPN. Bond strength between the IPN and tissue (i.e., muscle, dermis, skin) was determined by a modified American Society for Testing and Materials peel test at constant peel rate. The IPNs provided adhesion values of up to 5.7N, which were three‐ to fivefold lower than that of the commercial tissue bioadhesive. The subcutaneous cage implant system was utilized to assess material host response and drug efficacy in vivo. IPN formulations elicited a more intense acute inflammatory response than the empty cage controls. Methylprednisolone acetate loaded within the IPNs lowered the level of inflammatory response to levels that were comparable to the empty cage baseline controls. In conclusion, a methodology was developed to quantify the tissue adhesiveness of an in situ photopolymerized IPN matrix containing anti‐inflammatory agents. The efficacy of drug‐loaded IPN in affecting the host inflammatory response was demonstrated in vivo. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 68A: 392–400, 2004
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Photopolymerization techniques and applications · Dental materials and restorations · Polymer composites and self-healing
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. 10.1002/(SICI)1097-4636(200008)51:2<164::AID-JBM4>3.0.CO;2-W10.1002/(SICI)1097-4636(200008)51:2<164::AID-JBM4>3.0.CO;2-W ↗
2. 10.1002/(SICI)1097-4636(1999)48:4<511::AID-JBM17>3.0.CO;2-V10.1002/(SICI)1097-4636(1999)48:4<511::AID-JBM17>3.0.CO;2-V ↗
3. Transdermal photopolymerization of poly(ethylene oxide)‐based injectable hydrogels for tissue‐engineered cartilage10.1097/00006534-199909020-00018 ↗
4. 10.1002/jbm.123710.1002/jbm.1237 ↗
5. 10.1002/(SICI)1097-4636(199723)38:3<191::AID-JBM2>3.0.CO;2-K10.1002/(SICI)1097-4636(199723)38:3<191::AID-JBM2>3.0.CO;2-K ↗
6. 10.1016/S0142-9612(02)00369-110.1016/S0142-9612(02)00369-1 ↗
7. 10.1163/1568562026044974110.1163/15685620260449741 ↗
8. 10.1002/jbm.a.1010610.1002/jbm.a.10106 ↗
9. 10.1002/macp.20035004210.1002/macp.200350042 ↗
10. Veis A · 1964 · 5
11. 10.1016/S0142-9612(01)00403-310.1016/S0142-9612(01)00403-3 ↗
12. 10.1021/bk-1997-068010.1021/bk-1997-0680 ↗
13. 10.1002/(SICI)1097-4636(199724)38:4<348::AID-JBM7>3.0.CO;2-O10.1002/(SICI)1097-4636(199724)38:4<348::AID-JBM7>3.0.CO;2-O ↗
14. 10.1097/00003246-200111000-0001510.1097/00003246-200111000-00015 ↗
15. 10.1053/rvsc.2001.051010.1053/rvsc.2001.0510 ↗
16. 1995 · 1526
17. 10.1172/JCI10813810.1172/JCI108138 ↗
18. JohnsonB BauerJM NiedermaierDJ CroneWC BeebeDJ.Exp Mech 2003. Submitted.
19. ASTMD 638‐99 Standard test method for tensile properties of plastics.West Conshohocken PA:ASTM;1999. p46–58.
20. ASTMD 1876‐01 Standard test method for peel resistance of adhesives (T‐peel test).West Conshohocker PA:vASTM;2001. p116–118.
21. Kao WJ · 1999 · 659
22. 10.1002/jbm.82028011010.1002/jbm.820280110 ↗
23. 10.1002/jbm.82025020510.1002/jbm.820250205 ↗
24. 10.1002/jbm.82029101410.1002/jbm.820291014 ↗
25. 10.1002/jbm.82028070910.1002/jbm.820280709 ↗
26. 10.1002/(SICI)1097-4636(199907)46:1<22::AID-JBM3>3.0.CO;2-R10.1002/(SICI)1097-4636(199907)46:1<22::AID-JBM3>3.0.CO;2-R ↗